For the Sick MHI2000

Page 35

MHI-2000 I/O Panel

FIGURE 3–8. Open Collector Output Operating an External Relay +V to match coil requirements (supplied by user) 1N4003 or similar diode TB1-TB8

Relay contacts to switch load

5

4

To user ground

GND

MHI-2000

MHI-2000 Interface Board

Programmable Interface Controller Up to seven additional low-voltage DC input or outputs are available at terminal block J2 on an optional Programmable Interface Controller, as shown in Figure 3–9. Use of the PIC board is application specific. Definition of input and output pins requires knowledge of PIC function. All input and output pins are similar to the ones shown in Figure 3–4 and Figure 3–6. FIGURE 3–9. Programmable Interface Controller Board

Rev A, January 2002

MHI-2000 Technical Reference Manual

3-9

Controls, Connectors, & Indicators

3

NOTE: A separate supply is required for relay coils with voltage ratings other than 12V.

Output 1

Page 36

Chapter

3

Controls, Connectors, & Indicators

TABLE 3–2. Expansion Board Input Connections

J2 Marked

Assignment

1 (INZ)

Height Input 1

2 (ANG)

Height Input 2

3 (TACH)

Height Input 3

4 (HT1)

Height Input 4

5 (HT2)

Height Input 5

6 (HT3)

Height Input 6

7 (HT4)

Height Input 7

8 (HT5)

Inzone Presence (connect to TB1-2)

9 +5V

+5V

10 GND

GND

11 CTSOUT

CTSOUT (RS-232)

12 CTSIN

CTSIN (TTL)

Special Inputs & Outputs Beep Beep is a solid-state, open-collector output that normally activates an audio tone to signal the operator. By default JH1 shunt is positioned from 2-3. This allows the beeper signal to be sent to the on board transducer. If you wish to send this signal to an external device use TB11 and set the JH1 shunt to positions 1-2.

Interface Board I/O Connections Table 3–3 shows the Interface Unit I/O Connections at Terminal Block TB1. Default assignments are indicated in parentheses. TABLE 3–3. Interface Board Comm Connections

TB9-1

HTXD

HOST TRANSMIT DATA

TB9-2

HRXD

HOST RECEIVE DATA

TB9-3

HDTR

HOST DATA TERMINAL READY

TB9-4

HCTS

HOST CLEAR TO SEND

TB9-5

GND

GROUND

TB10-1

TTXD

TERMINAL TRANSMIT DATA

TB10-2

TRXD

TERMINAL RECEIVE DATA

TB10-3

TDTR

TERMINAL DATA TERMINAL READY

TB9-6

3-10

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 37

MHI-2000 I/O Panel

TABLE 3–3. Interface Board Comm Connections (Continued)

TB10-4

TCTS

TERMINAL CLEAR TO SEND

TB10-5

GND

GROUND

TB11-1

STXD

SETUP TRANSMIT DATA

TB11-2

SRXD

SETUP RECEIVE DATA

TB11-3

GND

GROUND

TB11-4

TERMDET

TERMINAL DETECT

TB11-5

BEEPER

BEEPER

TB11-6

GND

GROUND

TB12-1

TXDD

TRANSMIT DATA D-PORT

TB12-2

RXDD

RECEIVE DATA D-PORT

TB12-3

GND

GROUND

TB12-4

+5V

+5V POWER

TB12-5

EXLASOFF

EXTERNAL LASER OFF

TB12-6

+12V

+12V POWER

TB13-1

T422+

RS-422 TRANSMIT (+)

TB13-2

T422-

RS-422 TRANSMIT (-)

TB13-3

R422+

RS-422 RECEIVE (+)

TB13-4

R422-

RS-422 RECEIVE (-)

TB13-5

GND

GROUND

TB10-6

Controls, Connectors, & Indicators

3

TB13-6

Expansion Board Input Connections Table 3–4 shows the Expansion Board Input Connection at Terminal Block J2. TABLE 3–4. Expansion Board Input Connections

J2 Marked

Assignment

1 (INZ)

Height Input 1

2 (ANG)

Height Input 2

3 (TACH)

Height Input 3

4 (HT1)

Height Input 4

5 (HT2)

Height Input 5

6 (HT3)

Height Input 6

7 (HT4)

Height Input 7

8 (HT5)

Inzone Presence (connect to TB1-2)

Rev A, January 2002

MHI-2000 Technical Reference Manual

3-11

Page 38

Chapter

3

Controls, Connectors, & Indicators

TABLE 3–4. Expansion Board Input Connections

J2 Marked

Assignment

9 +5V

+5V

10 GND

GND

11 CTSOUT

CTSOUT (RS-232)

12 CTSIN

CTSIN (TTL)

Connectors on Front Panel Refer to Table 3–5 and Table 3–6, “I/O Connector” on page 3-13 for connector and signal specification for the MHI-2000 Front Panel. TABLE 3–5. Front Panel Connections

Pin

AUXILIARY

1

STARNODE

SETUP

(SETUP/1400)

LAN+ (blue wire)

2

Host RXD

TERM DETECT

Setup TXD Setup RXD

3

Host TXD

LAN- (white wire)

4

Host DTR

Ground

5

Ground

Frame Ground (cable shield)

6

Ground

Ground

7 8

Host CTS

9

Ground Ground

TERM RXD

Setup RXD

TERM TXD

Setup TXD

+5 VDC, 350 mA max

+5 VDC, 350 mA max

FIGURE 3–10. Front Panel Connectors 6

9

9

1

5

6

5

1 Male

Female

Auxiliary

Setup & Starnode

Auxiliary Connector Auxiliary Connections are also available on TB9 on the Interface Board. The Auxiliary Connector provides an asynchronous serial I/O port that can be used to connect to a host computer or to other serial, ASCII devices (such as printer, display terminals, external keyboards, etc.). Control of data flow, baud rates, etc., is determined by parameters you can set. Refer to Appendix E, “Parameters,” for more information. This port can use RS-232 or full modem protocols. RS-422 communication is available with the interface box only. Pins 2, 3, and 5 are always used for RS-232 communication. Pins 1, 6, 7, and 9 are reserved for RS-422 communication. Your host may require you to use other pins or make other connections in order to send and receive data.

3-12

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 39

MHI-2000 I/O Panel

Starnode Connector The Starnode Connector allows the MHI-2000 to be connected to an EIA-485 Starnode local area network (LAN). This network connection is not implemented in the Interface Unit. You must attach your network cable directly to the connector on the front panel of the MHI-2000. Refer to Table 3–5, “Front Panel Connections” on page 3-12.

Terminal Port Functionality on Starnode Connector

Setup Connector The SETUP connector is provided as an input port for a local terminal. You can connect an ASCII terminal or a PC running a terminal emulation program. This port uses RS-232 conventions and runs at 9600 baud. Refer to Table 3–5, “Front Panel Connections” on page 3-12. Setup connections are also available on TB11 on the Interface Board. A terminal can be used to display and change parameters values and run diagnostic tests. Most terminals only require connection to pins 2, 3 and 5. You can configure the setup port to use a CiMAX 1400 Hand-Held Terminal by changing the default cable from J10 to J8 on the Command and Control Board, internal to the MHI-2000.

Ethernet Connector An RJ-45 connector for 10baseT twisted pair is provided. No Ethernet connections are available in the Standard or Hex Interface Units. You must attach your network cable directly to the RJ-45 connector on the front panel of the MHI-2000.

I/O Connector The cable connecting the Command and Control PCB to the Interface PCB is plugged into the I/O Connector, as shown in Table 3–6. TABLE 3–6. I/O Connector

Signal

Pin #

Output 1

38

Input 1

8

Output 2

14

Input 2

33

Output 3

39

Input 3

9

Output 4

15

Input 4

34

Output 5

40

Input 5

10

Rev A, January 2002

MHI-2000 Technical Reference Manual

3-13

3

Controls, Connectors, & Indicators

The Starnode Connector can also be used to access the Terminal port so it can be used as a Setup Port. Terminal Port uses RS-232 conventions. Refer to Table 3–5, “Front Panel Connections” on page 3-12. CiMAX 1400 is powered by pins 6 and 9. Pin 2 is a terminal detect pin used by the MHI-2000 to detect CiMAX 1400 presence.

Page 40

Chapter

3

Controls, Connectors, & Indicators

TABLE 3–6. I/O Connector (Continued)

Signal

3-14

Pin #

Output 6

16

Input 6

35

Output 7

41

Input 7

11

Output 8

17

Input 8

36

RXDD

24

Beep

23

+12V

21

Ground

45

+5V

43

N/C

22

Ground

37

+12V

44

TXDD

25

Host TXD

1

Host RXD

26

Host DTR

2

Host CTS

27

TERM TXD

3

TERM RXD

28

TERM DTR

4

TERM CTS

29

T422+

6

T422-

31

R422+

7

R422-

32

TERM DET

50

Setup TXD

5

Setup RXD

30

+5V

49

Laser Control

47

+5V

48

Ground

20

+5V

18

+12V

46

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 41

MHI-2000 I/O Panel

TABLE 3–6. I/O Connector (Continued)

Pin #

Ground

12

Ground

13

+12V

19

Frame Ground

42

3

50-Pin Cable Connector This connector plugs into the I/O Connections jack on the MHI-2000 front panel, and is shown in Figure 3–11. FIGURE 3–11. 50 Pin Centronics Connector

Rev A, January 2002

1

25

26

50

MHI-2000 Technical Reference Manual

3-15

Controls, Connectors, & Indicators

Signal

Page 42

Chapter

3-16

3

Controls, Connectors, & Indicators

MHI-2000 Technical Reference Manual

Rev A, January 2002