The text of a manual · part 4 of 25
MHI-2000 Technical Reference Manual: CHAPTER 2 Installation & Setup
Pages 23 to 26 of 207, from MHI-2000 Technical Reference Manual
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick MHI2000
Page 23
2 Installation & Setup
CHAPTER 2
This chapter provides you with an overview of the MHI-2000 hardware installation and setup. It also describes interconnections for the interface terminal board.
Unpacking & Inspection Unpack the MHI-2000 and any accessories ordered. Depending on what you ordered, the equipment may have been shipped in more than one carton. Remove the packing list from the pocket on each carton. Verify that you have received all of the items shown on the packing list. Inspect the equipment for shipping damage and, if any exists, notify both the carrier and SICK Auto Ident, Inc. immediately. Store the original packing material inside each carton, and store the cartons in a safe place. If the MHI-2000 or any accessories need to be repaired, upgraded, or modified in the future, return them to SICK Auto Ident, Inc. in the original cartons with the original packing material. Refer to “Product Warranty” on page xix and “Return-to-Factory Instructions” on page xviii for more information.
Installation Checklist •
Plan and schedule complete installation.
•
Identify and include personnel responsible for:
•
Rev A, January 2002
–
Data system
–
Control or conveyor system
–
Maintenance
–
Installation
Review plan with SICK Auto Ident, Inc. Field Service Engineer - Confirm schedule two weeks prior to engineer arriving on site for functional checkout.
MHI-2000 Technical Reference Manual
2-1
Installation & Setup
2
Page 24
Chapter
2
Installation & Setup
Site Preparation Refer to the Keysheet. •
AC power to MHI-2000. Ensure AC power is connected to an earth ground.
•
AC power (convenience outlets) for local PC, CRT, modem, oscilloscope. Ensure AC power is connected to an earth ground.
•
Setup/Diagnostic Terminal - Local CRT, or PC running serial communications software program, i.e., Microsoft Windows HyperTerminal, ProComm, or Telix.
Electrical Connections To MHI-2000 •
Grounded, AC power
•
Network (if used)
•
Presence photoeyes
•
Tachometer (installer provides cable)
•
Height-sensing photoeyes
•
Communication cable(s) provided by installer
•
Any special digital I/O connections
•
Modem and cables, provided by installer
Site Preparation Power 115/230 VAC line power must be brought to the MHI-2000. You should also provide additional 115 VAC outlets for setup and diagnostic test equipment.
Setup You should have one of the following: •
PC with terminal emulation software and cable
•
RS-232 ASCII terminal
Communications wiring to the host is necessary.
Photoeyes & Tachometer Installation Follow the installation directions only if your system requires presence photoeyes, height-detecting photoeyes, and a tachometer.
2-2
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 25
Site Preparation
Installing the Tachometer
You must provide a custom bracket to mount the tachometer securely to your conveyor. Connect the tachometer to a driven roller or other driven rotational part of your conveyor using a flexible shaft coupling or a belt and pulley drive, as shown in Figure 2–1. FIGURE 2–1. Tachometer Driver by Flexible Shaft Coupling
Tachometer Housing
Shaft Coupling
Note: You must use an appropriate flexible shaft coupling or belt and pulley drive to provide mechanical isolation of the tachometer from your conveyor. Without such isolation, the tachometer is subject to misalignment, roller shaft wobble, and consequent wear to the tachometer's precision bearings. Alternatively, a friction wheel can be used to couple the tachometer to the surface of a belted conveyor. Friction drives have the potential to slip and cause tracking errors over time, but may be suitable for your application. A suitable measuring wheel (P/N 16002070215) with a 12” circumference, a white rubber surface, and an inside diameter compatible with the standard SICK Auto Ident, Inc. tachometer, and a universal tracking mounting base (P/N 14005750000), can be purchased from: Danaher Controls 1675 Delany Road Gurnee, IL 60031 The MHI-2000 requires inputs from a tachometer that produces a conveyor travel resolution finer than 0.20 inches per pulse with a pulse rate of no more than 1 kHz. Lower resolution will affect position accuracy but may provide enough accuracy for your application. The examples in Table 2–1 display conveyor travel per pulse if a 300-pulses/revolution tachometer is driven directly from conveyor rollers of the diameters indicated. The speeds listed produce 1 kHz pulse rates.
Rev A, January 2002
MHI-2000 Technical Reference Manual
2-3
2 Installation & Setup
A tachometer, which measures conveyor movement, is required for gap tracking. Gap tracking is required when there is the possibility that more than one box may be in the scanning zone at the same time.
Page 26
Chapter
2
Installation & Setup
TABLE 2–1. Conveyor Travel per Pulse
Roller diameter:
2 inches
3 inches
4 inches
Resolution:
0.021 inches
0.031 inches
0.042 inches
Conveyer Speed:
21 inches/sec 105 ft/min
31 inches/sec 157 ft/min
42 inches/sec 210 ft/min
If you use higher conveyor speeds, connect the tachometer directly to a larger diameter driven roller, or use a belt and pulley system to achieve slower tachometer rotation, as shown in Figure 2–2. Optionally, use a tachometer that generates fewer pulses per revolution. Figure 2–2 displays a pulley arrangement providing a speed reduction of 3 to 1 and a 33% decrease in tachometer resolution. FIGURE 2–2. Pully Arrangement
Conveyor Conveyor Roller 1”Dia.
3”Dia.
Tach Drive Pulley
The speed reduction will be proportional to the ratio of the pulley diameters, with the tachometer connected to the larger diameter pulley. The resolution will decrease in inverse proportion to the ratio of the diameters.
Mounting Presence Photoeyes The photoeye positions for your application are specified on your Keysheet.
Mounting Photoeye Tree Bracket The bracket supports the height-detecting photoeyes on one side of the conveyor. A second bracket supports reflectors for each photoeye on the other side of the conveyor. Mount the height-detecting photoeyes immediately upstream of the inzone photoeye. Dimensions of the bracket available from SICK Auto Ident, Inc. are listed in “Photoeye Tree Bracket” on page C-3.
2-4
MHI-2000 Technical Reference Manual
Rev A, January 2002