The text of a manual · part 3 of 25
MHI-2000 Technical Reference Manual: CHAPTER 1 Overview & Maintenance
Pages 19 to 22 of 207, from MHI-2000 Technical Reference Manual
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick MHI2000
Page 19
1 Overview & Maintenance
1 Overview & Maintenance
CHAPTER 1
This chapter provides you with an overview of, and specifications and maintenance for, the MHI-2000.
Overview Typical Physical Setup The MHI-2000 may be used with other equipment, such as photoeyes and a tachometer.
Keysheet The Keysheet specifies the details of your MHI-2000 setup. It is based on information you provided to SICK Auto Ident, Inc. about your MHI-2000 application. The information in the Keysheet customizes the MHI-2000 hardware and software setup for your site. Do not deviate from the Keysheet or otherwise change the configuration without consulting SICK Auto Ident, Inc.
Software Updates Software updates from SICK Auto Ident, Inc. can include changes and improvements in the following: •
Operating System
•
Code for Gap Tracking
•
Network
•
File Memory
•
C code
SICK Auto Ident, Inc. will provide software to you, as your application requires. These updates can be uploaded into your MHI-2000 from your PC, with the software available from SICK Auto Ident, Inc. on a diskette. The MHI-2000 uses flash memory to allow complete re-programming in the field.
Rev A, January 2002
MHI-2000 Technical Reference Manual
1-1
Page 20
Chapter
1
Overview & Maintenance
Specifications MHI-2000 Configuration Memory •
2M (approx. 800K for user C programs and data)
Network •
Starnode
•
Ethernet 10 base T
•
Additional Ethernet 10 base T (optional)
Optional Solid-State Input/Output Modules Two optically isolated Opto-22 style modules may be installed as inputs or outputs. They are controlled by standard input/output signals. •
IDC15 Type-DC Input (10-32 VDC)
•
ODC15 Type-DC Output (5-60 VDC)
•
IAC15 Type-AC Input (90-140 VAC)
•
OAC15 Type-AC Output (90-140 VAC)
•
IAC15A Type-AC Input (180-280 VAC)
•
OAC15A Type-AC Output (180-280 VAC)
Optional Programmable Interface Controller For some special applications, an additional PIC board may be installed.
Physical For mechanical drawings with dimensions, refer to Appendix C, “Dimension Diagrams”.
MHI-2000 •
10.75 x 6.5 x 5 inches (273 x 165.1 x 127 mm)
•
5.5 pounds (2.5 kilograms)
Power
1-2
•
Input - 115/230 +/-10% VAC @ 2.0/1.0 A, 50/60 Hz
•
Output - DC power - +12 VDC, 750 mA to photocells, tachometer, etc. +5 VDC, 375 mA to tachometer
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 21
Construction A single integrated package consisting of an aluminum enclosure, fully gasketed, and mounted on a 1/2 inch (12.7 mm) aluminum base plate.
Environmental •
Dust-tight and drip-proof
•
Operating Temperature - 32° to 122° F (0° to 50° C)
•
Humidity - 5% to 95% non-condensing
LED Status Indicators Ten LEDs on a single display monitor operations and communications.
Communications There are six independent communications ports: •
1 asynchronous serial Host port (RS-232) I/O connector
•
1 asynchronous serial Terminal/Slave port (RS-232)
•
1 asynchronous serial Setup port (RS-232)
•
1 asynchronous serial D-port (RS-232)
•
1 RS-485 LAN port with Starnode protocol
•
1 Ethernet port (10 base T)
Inputs Eight total, active low when <1.0 VDC. •
Maximum input 30 VDC intermittent, 27 VDC continuous
Outputs Eight total, open collector solid state - 30 VDC at 150 mA, max.
Rev A, January 2002
MHI-2000 Technical Reference Manual
1-3
1 Overview & Maintenance
Specifications
Page 22
Chapter
1
Overview & Maintenance
Maintenance The MHI-2000 requires no special maintenance when operated in an environment free from extremes of temperature, humidity, shock, and vibration. Perform the following tasks once a month to keep the MHI-2000 clean and to inspect it for mechanical damage. 1.
Switch MHI-2000 main power OFF before cleaning it.
2.
Clean dirt and dust from the MHI-2000’s LED display, using a soft, lint-free cloth and a nonabrasive liquid cleaner. DO NOT use an abrasive cleaner.
3.
Check all cables for signs of abrasion.
4.
Check that all cable connections are secure.
Caution: The MHI-2000’s internal components do NOT require maintenance. Opening the MHI-2000 with power applied can expose you to electrical and mechanical hazards, which can cause bodily injury.
1-4
MHI-2000 Technical Reference Manual
Rev A, January 2002