Page 131
002 - 027 Decoding & Operation Parameters
007
DEBUG DATA PORT DEBUG DATA PORT Valid Values
0 - 4095 Add 1, Enable sending debug data out Terminal Port Add 2, Enable sending debug data out Host Port Add 64, Enable sending debug data out Starnode Port Add 128, Enable sending debug data out Setup Port Add 256, Enable sending debug data out TCP1 Port Add 512, Enable sending debug data out TCP2 Port Add 1024, Enable sending debug data out TCP3 Port Add 2048, Enable sending debug data out Telnet Port 0000 (Disable reporting of debug data)
Description
This parameter allows you to select which port should receive special debugging information (as defined in Parameter 006 DEBUG DATA). By setting this parameter accordingly, debug data can be sent out any combination of communication ports. This is useful when debugging a working system that may, for example, be communicating to a host system via the Terminal port. Debug data won't be sent out the Terminal port if this port is not enabled. If, however, a computer is connected to the Setup port, then entering 128 would enable any debug reporting to be seen on this port. For example, a setting of 385 sends debug data to the TCP1 Port (256), the setup port (128), and the Terminal port (1). Notice that 256 + 128 + 1 = 385. 007 DEBUG DATA PORT uses the same format as 003 IO MODE, except that: TABLE E–10. TUNNEL MULTI READS Valid Values and Descriptions
Rev A, January 2002
For Parameter...
You set a bit to...
0007 DEBUG DATA PORT
Enable the data output.
0003 IO MODE
Disable the data output.
MHI-2000 Technical Reference Manual
E-11
Parameters
E
Default Value
Page 132
Appendix
011
E
Parameters
NO READ CHAR NO READ CHARACTER Valid Values
Decimal 001 - 122
Default Value
Decimal 063 ( ASCII ? )
Description
The NO READ CHAR is sent in the data field of the device’s output message in place of barcode data characters if no barcode was read during a Presence cycle (a box entered and exited the scan zone). The default no read character ? can be replaced by any other ASCII character by changing the value of this parameter. The “ASCII Equivalence Table” in your device’s Technical Reference Manual contains an ASCII - decimal conversion table. Enter a value of 000 to disable this parameter.
E-12
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 133
002 - 027 Decoding & Operation Parameters
012
LABEL SEPARATOR LABEL SEPARATOR Valid Values
Decimal 001 - 122
Default Value
Decimal 044 (ASCII , )
Description
The separator character is used to separate multiple barcodes sent by the device to the host in a single, formatted string when multiple barcodes have been read on one scanned object. Any other ASCII character can replace the default separator character, by changing the value of this parameter. The “ASCII Equivalence Table” in your device’s Technical Reference Manual contains an ASCII - decimal conversion table. Enter a value of 000 to disable this parameter.
Parameters
E
Rev A, January 2002
MHI-2000 Technical Reference Manual
E-13
Page 134
Appendix
013
E
Parameters
MULTI READ CHAR MULTIPLE READ CHARACTER Valid Values
Decimal 001 - 122
Default Value
Decimal 035 (ASCII # )
Description
The scanner can be programmed to detect multiple unique and non-unique barcodes on one object, and to report an error if one or the other or both are detected. If so programmed, the scanner will present multiple read characters instead of barcode characters. The multiple read character is sent in the data field of the scanner’s output message in place of barcode data characters if multiple unique barcodes were read during the Presence cycle. The default multiple read character # can be replaced by any other ASCII character by changing the value of this parameter. The “ASCII Equivalence Table” in your scanner’s Technical Reference Manual contains an ASCII decimal conversion table. Enter a value of 000 to disable this parameter.
E-14
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 135
002 - 027 Decoding & Operation Parameters
027
TUNNEL MULTI READS TUNNEL MULTI READS Valid Values
0 or 1
Default Value
0
Description
Table E–11 lists the TUNNEL MULTI READS valid values and their descriptions. TABLE E–11. TUNNEL MULTI READS Valid Values and Descriptions
Value
Description
0
Disables the reporting of multireads in the Tunnel Master Application Mode.
1
Enables the reporting of multireads in the Tunnel Master Application Mode.
Parameters
E
Rev A, January 2002
MHI-2000 Technical Reference Manual
E-15
Page 136
Appendix
E
Parameters
100-173 Serial Communications Parameters These parameters set the operating characteristics of the HOST, TERMINAL, SETUP and D-Port ports, such as baud rate, parity and stop bits, transmit protocol, and input or output prefixes and suffixes.
100 120 140 160
BAUD RATE HOST BAUD RATE TERM BAUD RATE SETUP BAUD RATE D-PORT Valid Values
0 - 11 0 - 14.4K bps 1 - 28.8K bps 2 - 300 bps 3 - 600 bps 4 - 1200 bps 5 - 2400 bps 6 - 4800 bps 7 - 9600 bps 8 - 19.2K bps 9 - 38.4K bps 10 - 57.6K bps 11 - 115.2K bps
Default Value
BAUD RATE HOST, 07 (9600 baud) BAUD RATE TERM, 07 BAUD RATE SETUP, 09 BAUD RATE D-PORT, 07
Description
The BAUD RATE parameters select the speed, in bits per second (bps), that data is transmitted through the port. The baud rate of a port should be set to match that of the device with which the port is communicating. For instance, if a port is connected to a non-intelligent terminal operating at 9600 baud, the port must be configured for 9600 baud.
E-16
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 137
100-173 Serial Communications Parameters
101 121 141 161
DATA BITS HOST DATA BITS TERM DATA BITS SETUP DATA BITS D-PORT DATA BITS Valid Values
7 or 8
Default Value
DATA BITS HOST, 8 DATA BITS TERM, 8 DATA BITS SETUP, 8 DATA BITS D-PORT, 8
Description
The DATA BITS parameters set the number of data bits in the transmitted field. It is permissible to use eight data bits plus a parity bit.
Parameters
E
Rev A, January 2002
MHI-2000 Technical Reference Manual
E-17
Page 138
Appendix
102 122 142 162
E
Parameters
PARITY HOST PARITY TERM PARITY SETUP PARITY D-PORT PARITY Valid Values
2-4 2, EVEN parity (sum of 1’s to be even) 3, ODD parity (sum of 1’s to be odd) 4, No parity
E-18
Default Value
PARITY HOST, 4 (No parity) PARITY TERM, 4 PARITY SETUP, 4 PARITY D-PORT, 4
Description
The PARITY parameters configure the device to be compatible with the parity-checking scheme used by the devices connected to a port. Parity is used to help detect errors in data transmission.
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 139
100-173 Serial Communications Parameters
103 123 143 163
STOP BITS HOST STOP BITS TERM STOP BITS SETUP STOP BITS D-PORT STOP BITS Valid Values
1 or 2
Default Value
1
Description
The STOP BITS parameters set the number of stop bits in the data field.
Parameters
E
Rev A, January 2002
MHI-2000 Technical Reference Manual
E-19
Page 140
Appendix
104 124 144 164
E
Parameters
FLOW CONTROL HOST FLOW CONTROL TERM FLOW CONTROL SETUP FLOW CONTROL D-PORT FLOW CONTROL Valid Values
0-3 The following values can be summed when entering a value for this parameter. 0, None Add 1, XON/XOFF Add 2, RTS/CTS
Default Value
FLOW CONTROL HOST, 0 FLOW CONTROL TERM, 0 FLOW CONTROL SETUP, 0 FLOW CONTROL D-PORT, 0
Description
The FLOW CONTROL parameters allow you to select the flow and control protocols to be used when the device transmits/receives data through the HOST, TERMINAL and SETUP ports. There are four options available.
XON/XOFF (1) This is a bi-directional control protocol. The device will send data through the selected port until it receives an XOFF (<DC3> character) from the receiving device, at which time it will stop transmitting. The device will resume transmission when it receives an XON (<DC1> character). The device will send an XOFF character when its Receive buffer has reached its full capacity of 256 characters. It will send an XON when its buffer empties to 224 characters.
RTS/CTS (2) This is a bi-directional control protocol. The device will assert Clear To Send (CTS) at the selected port whenever it is prepared to receive data. It will drop CTS when its Receive buffer reaches its maximum capacity of 256 characters. It will assert CTS again when its Receive buffer empties to 32 characters. The device will send data from the selected port until the receiving device drops DTR (Data Terminal Ready). The device will resume data transmission when the receiving device asserts DTR again.
E-20
MHI-2000 Technical Reference Manual
Rev A, January 2002