Page 141

100-173 Serial Communications Parameters

105 125 145 165

IN PRE. HOST IN PRE. TERM IN PRE. SETUP IN PRE. D-PORT INPUT PREFIX CHARACTER Valid Values

000 - 255

Default Value

000

Description

The INPUT PREFIX parameters select the ASCII prefix character. If set to non-zero, this character must be received by the device before any data will be accepted. The prefix character is stripped from the data prior to its use.

Parameters

E

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-21

Page 142

Appendix

106 126 146 166

E

Parameters

IN SUF. HOST IN SUF. TERM IN SUF. SETUP IN SUF. D-PORT INPUT SUFFIX CHARACTER Valid Values

000 - 255

Default Value

000

Description

The INPUT SUFFIX parameters select an ASCII suffix character. When set to non-zero, it is used as a terminator for data being received by the device. Serial data received through the selected port will be accumulated from the time that an input prefix character is received until the time that the suffix character is received. If the Serial Input Buffer reaches its capacity before the suffix character is received, the data will be presented as though it were a complete block. This prevents the Serial Input Buffer from overflowing and losing data. The suffix character may or may not be presented with the data, depending upon the value of the parameter. •

If the suffix should not be presented with the data, select an ASCII character and enter its decimal value (000 - 127).

•

If the suffix should be presented with the data, select an ASCII character, add 128 to its decimal value, and enter the summed value.

Example To present a block of data with a <CARRIAGE RETURN> as the suffix character, enter the value 141 (013, the decimal value for <CARRIAGE RETURN>, plus 128).

E-22

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 143

100-173 Serial Communications Parameters

107 127 147 167

OUT PRE. HOST OUT PRE. TERM OUT PRE. SETUP OUT PRE. D-PORT OUTPUT PREFIX CHARACTER Valid Values

000 - 255

Default Value

000

Description

The OUTPUT PREFIX parameters select an ASCII prefix character. When set to non-zero, it will precede all data transmitted from the device.

Parameters

E

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-23

Page 144

Appendix

108 128 148 168

E

Parameters

OUT SUF. 1 HOST OUT SUF. 1 TERM OUT SUF. 1 SETUP OUT SUF. 1 D-PORT OUTPUT SUFFIX 1 CHARACTER Valid Values

000 - 255

Default Value

Decimal 128 (CR - LF) (this is a non-standard ASCII decimal code) 000 (Parameter 168 only)

Description

The OUTPUT SUFFIX 1 parameters select a first ASCII suffix character. When set to non-zero, the suffix character will be appended to the end of each data block transmitted through the selected port of a device.

E-24

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 145

100-173 Serial Communications Parameters

109 129 149 169

OUT SUF. 2 HOST OUT SUF. 2 TERM OUT SUF. 2 SETUP OUT SUF. 2 D-PORT OUTPUT SUFFIX 2 CHARACTER Valid Values

000 - 255

Default Value

000

Description

The OUTPUT SUFFIX 2 parameters select a second ASCII suffix character. With Block Mode Output enabled, it will be appended after the first suffix character (if one is selected), to the end of each block of data transmitted. If an OUTPUT SUFFIX 2 character is specified, only the selected SUFFIX ONE character immediately followed by the selected SUFFIX TWO character will be recognized as a data terminator.

Parameters

E

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-25

Page 146

Appendix

110 130 150 170

E

Parameters

ERROR HOST ERROR TERM ERROR SETUP ERROR D-PORT ERROR CHARACTER Valid Values

000 - 255

Default Value

000

Description

The ERROR CHARACTER parameters select an ASCII character that will be substituted for any character that is received through the selected port with a parity or framing error. If the Serial Input buffer reaches capacity, the error character will be stored as the last character in the buffer. This allows the calling routine to trap serial errors. Assigning a value greater than decimal 127 disables this feature, and all data will be presented as received.

E-26

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 147

100-173 Serial Communications Parameters

111 131 171

PROTOCOL HOST PROTOCOL TERM PROTOCOL DPORT PROTOCOL HOST, PROTOCOL TERMINAL, PROTOCOL DPORT Valid Values

00 - 10 (Parameters 111, 131, 171)

Valid Values

00, Normal communications mode 01, Polling Mode D (Master) 02, Polling Mode D (Slave) 03, Crisplant Sorter 04, Serial Master 05, Serial Slave (TX/RX Same Port)

E

06, Serial Slave (TX/RX Different Port)

09, External Data Input 10, Telnet Redirect Default Value

00

Description

The PROTOCOL parameters select special communications protocols. For Polling Mode D, refer to Intermec Data Communications Reference Manual, Intermec P/N 044737-001.

Rev A, January 2002

•

00, No additional serial communication protocols are selected.

•

01, Identifies the given port to be the Master in a Polling Mode D scanner network. This is an RS485 communication protocol. Refer to Intermec Data Communications Reference Manual, Intermec P/N 044737-001, for specific details on this protocol.

•

02, Identifies the given port as a slave in a Polling Mode D scanner network. Note that a protocol address (112, 132, 172) is required for proper operation.

•

03, The Crisplant SC2000 controller-scanner interface is implemented on this serial port. This is an RS422 based interface. This protocol is used when interfacing to a Crisplant sorter.

•

04, Serial Master identifies the port to serve as the Master in a serial Master/Slave network. The function of the Master is to collect the barcode data from all of the slaves and it’s own data and compile the decode format result for presentation to the Host system. This protocol requires that block

MHI-2000 Technical Reference Manual

E-27

Parameters

08, Height Input

Page 148

Appendix

E

Parameters mode be used by defining a message prefix and suffix for this input port. The block mode characters must match those set on the Slave output port.

E-28

•

05, Identifies Serial Slave where only one serial port is used for transmit and receive of slave data. In this scheme, if, for example, the Terminal port is used for slave data, then the first slave transmits out of its Terminal port to the Master. The next slave transmits out its Terminal port to the first slave’s Terminal port. This chain continues for the number of slaves in the network. Each slave passes along any data that it receives in its Terminal port (from another slave in the chain) ultimately up to the Master.

•

06, In this method of Serial Slave protocol, both the Terminal and Host serial ports are required (when there is more than one slave). Either the Terminal or Host port is defined as the Serial Slave In port (the port in which additional slave data is routed). Then, the alternate port is used to send data up the chain ultimately to the Master.

•

07, This is not a valid serial protocol setting. This is used to define a PC based Tunnel interface that is only available on the Starnode or Ethernet (TCP) ports.

•

08, The Height Input protocol is used when an external serial height sensor is used. For example, a height tree provides serial height information. This protocol enables these devices to be easily integrated with the scanner.

•

09, The External Data protocol is a specialized Master protocol for use when interfacing with an MHV Camera. This is most often done with an MHI-2000.

•

10, The Telnet redirect protocol is used to redirect serial data from any of the four serial ports (Host, Terminal, Setup, or D port) to a Telnet port (Ethernet). The Protocol Address parameter defines the Telnet port address.

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 149

100-173 Serial Communications Parameters

112 132 172

PROTOCOL ADDR HOST PROTOCOL ADDR TERM PROTOCOL ADDR DPORT PROTOCOL ADDRESS 0 - 65536

Default Value

00000

Description

The scanner address for serial protocols. This parameter is closely associated with the serial Protocol parameter. It has the following meaning, based on the defined Protocol: Polling Mode D Master

When a port is defined as the Polling mode D Master port, the Protocol Address defines the number of slaves in the network.

Polling Mode D Slave

When a port is defined as a Polling Mode D Slave port, the Protocol Address defines the slave’s unique Slave address.

Telnet Redirect

When a port is defined as a Telnet redirect port, the Protocol Address defines the Telnet port address.

Other Protocols

For all other serial protocols, the Protocol Address is undefined.

For Serial Master, the Protocol Address is a bitmap setting of the devices it is connected to. For Serial Slave, the Protocol Address is the address of the slave.

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-29

E Parameters

Valid Values

Page 150

Appendix

113 133 173

E

Parameters

HARDWARE OPTS HOST HARDWARE OPTS TERM HARDWARE OPTS DPORT HARDWARE OPTS Valid Values

0 or 1 (Parameter 113) 0 (Parameters 133, 173)

E-30

Default Value

0

Description

A 1 turns on RS422. This is only supported on the Host port.

MHI-2000 Technical Reference Manual

Rev A, January 2002