The text of a manual · part 20 of 25
MHI-2000 Technical Reference Manual: APPENDIX E Parameters, pages 151 to 160
Pages 151 to 160 of 207, from MHI-2000 Technical Reference Manual
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick MHI2000
Page 151
200-274 BIN x Decoding Group Parameters
200-274 BIN x Decoding Group Parameters These parameters set the decoding characteristics of the MHI-2000.
BIN 1 SYMBOLOGY BIN 2 SYMBOLOGY BIN 3 SYMBOLOGY BIN 4 SYMBOLOGY BIN 5 SYMBOLOGY BIN 6 SYMBOLOGY BIN 7 SYMBOLOGY BIN 8 SYMBOLOGY Valid Value
00, 10, 20, 50
Default Value
BIN 1 SYMBOLOGY, 10 BIN 2 SYMBOLOGY, 00 BIN 3 SYMBOLOGY, 00 BIN 4 SYMBOLOGY, 00 BIN 5 SYMBOLOGY, 00 BIN 6 SYMBOLOGY, 00 BIN 7 SYMBOLOGY, 00 BIN 8 SYMBOLOGY, 00
Description
The mandatory SYMBOLOGY parameter is a two-digit value that tells the scanner which symbology to decode.
E Parameters
200 210 220 230 240 250 260 270
210 BIN 2 SYMBOLOGY sets the symbology for the sub bin. The implemented symbologies are: •
Code 128 ( 10 )
•
Code 39 ( 20 )
•
Interleaved 2 of 5 ( 50 )
A zero setting disables the symbology for the bin. The scanner decodes the symbologies listed in Table E–12. TABLE E–12. Scanner Decodes and Symbologies
Rev A, January 2002
Values
Valid Barcode Symbologies
10
Code 128*
20
Code 39
50
Interleaved 2-of-5
MHI-2000 Technical Reference Manual
E-31
Page 152
Appendix
201 211 221 231 241 251 261 271
E-32
E
Parameters
BIN 1 MIN LENGTH BIN 2 MIN LENGTH BIN 3 MIN LENGTH BIN 4 MIN LENGTH BIN 5 MIN LENGTH BIN 6 MIN LENGTH BIN 7 MIN LENGTH BIN 8 MIN LENGTH Valid Values
0 - 64
Default Value
BIN 1 MIN LENGTH, 0 BIN 2 MIN LENGTH, 0 BIN 3 MIN LENGTH, 0 BIN 4 MIN LENGTH, 0 BIN 5 MIN LENGTH, 0 BIN 6 MIN LENGTH, 0 BIN 7 MIN LENGTH, 0 BIN 8 MIN LENGTH, 0
Description
Defines the minimum expected barcode length.
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 153
200-274 BIN x Decoding Group Parameters
BIN 1 MAX LENGTH BIN 2 MAX LENGTH BIN 3 MAX LENGTH BIN 4 MAX LENGTH BIN 5 MAX LENGTH BIN 6 MAX LENGTH BIN 7 MAX LENGTH BIN 8 MAX LENGTH Valid Values
0 - 64
Default Value
BIN 1 MAX LENGTH, 0 BIN 2 MAX LENGTH, 0 BIN 3 MAX LENGTH, 0 BIN 4 MAX LENGTH, 0 BIN 5 MAX LENGTH, 0 BIN 6 MAX LENGTH, 0 BIN 7 MAX LENGTH, 0 BIN 8 MAX LENGTH, 0
Description
Rev A, January 2002
E Parameters
202 212 222 232 242 252 262 272
Defines the maximum expected barcode length.
MHI-2000 Technical Reference Manual
E-33
Page 154
Appendix
203 213 223 233 243 253 263 273
E
Parameters
BIN 1 CHAR POS BIN 2 CHAR POS BIN 3 CHAR POS BIN 4 CHAR POS BIN 5 CHAR POS BIN 6 CHAR POS BIN 7 CHAR POS BIN 8 CHAR POS Valid Values
0 or 1
Default Value
0
Description
This parameter indicates whether the CHAR CHECK characters will be at the start or the end of the label. Table E–13 lists the BIN x CHAR POS valid values and their descriptions. TABLE E–13. BIN x CHAR POS Valid Values and Descriptions
E-34
Values
Description
0
The start of a label.
1
The end of a label.
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 155
200-274 BIN x Decoding Group Parameters
BIN 1 CHAR CHECK BIN 2 CHAR CHECK BIN 3 CHAR CHECK BIN 4 CHAR CHECK BIN 5 CHAR CHECK BIN 6 CHAR CHECK BIN 7 CHAR CHECK BIN 8 CHAR CHECK Valid Value
One, two, or no ASCII characters. Both printable and non-printable characters can be entered in the same string.
Default Value
NONE
Description
These parameters consist of one or two ASCII characters that are used to only select barcodes that begin or end (as defined by parameter CHAR POS) with these characters, screening out barcodes that do not begin with these characters. Enter a printing character just as it would be printed. Enter a non-printing character in the format \xnn, where nn are the two hexadecimal characters that define the non-printing character. The “ASCII Equivalence Table” in your device’s Technical Reference Manual lists the hex equivalents of all ASCII non-printing characters. For example, the ASCII non-printing GS (group separator) characters found in UCC/EAN-128 and UCC-128 SSCC (serial shipping container code) formatted Code -128 bar codes can be entered as \x1D. The 230 BIN 4 SYMBOLOGY string contains up to two characters to use in screening labels for a bin.
Default
Rev A, January 2002
If no characters are entered for this element, then no barcode ID character screening will be done.
MHI-2000 Technical Reference Manual
E-35
E Parameters
204 214 224 234 244 254 264 274
Page 156
Appendix
E
Parameters
400 - 404 Starnode Setup Parameters Two parameters, 401 TERM. NUMBER and 402 TERM. TYPE, are provided for STARNODE operations. If STARNODE operations will be invoked, both parameters should have their values set appropriately.
400
STARNODE PROTOCOL STARNODE PROTOCOL Valid Values
0 or 7
Default Value
0
Description
This parameter indicates the protocol used for reporting data over Starnode. When set to 0, normal Starnode communication is used, if a valid Terminal # (parameter 401) and Terminal Type (parameter 402) have been set. Additional Tunnel protocol is achieved when this parameter is set to 7. 0, Starnode Protocol. 7, PC-Based Tunnel Protocol over Starnode. This protocol is used when interfacing a device in a Starnode based PC Tunnel network. The PC runs our Tunnel application, which coordinates the communication of an array of devices and provides extensive system capabilities. Please consult the factory for detailed information on the Tunnel application.
E-36
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 157
400 - 404 Starnode Setup Parameters
401
TERM. NUMBER STARNODE TERMINAL NUMBER Valid Values
0 - 4095
Default Value
0000 (None)
Description
Each device connected to the STARNODE network must be assigned a unique terminal number that identifies that device to the STARNODE network. A valid terminal type (parameter 402) must also be entered.
Parameters
E
Rev A, January 2002
MHI-2000 Technical Reference Manual
E-37
Page 158
Appendix
402
E
Parameters
TERM. TYPE TERMINAL TYPE Valid Values
0 - 126
Default Value
000 (None)
Description
If C programs are to be automatically downloaded to devices through a network, all devices on the network must be assigned a terminal type. These type numbers determine which C programs are downloaded to each device. For example, if device terminal numbers 0001, 0004, and 0007 are all designated as Type 004, and if the program SHIP.l2k is assigned to all Type 004 terminals, then the STARNODE controller will automatically download SHIP.l2k to all three devices upon network startup. Terminal type may also be used for Ethernet networks; however, it is not required. Note: No program can be downloaded over a Starnode network to a device designated as type 000.
E-38
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 159
400 - 404 Starnode Setup Parameters
403 404
MSG CHAR PREFIX MSG CHAR SUFFIX MESSAGE CHARACTER PREFIX/SUFFIX Valid Values
Decimal 032 - 126
Default Value
Decimal 126 = ~ (tilde)
Description
These characters must frame all command messages sent to the device. For example, to get the status string of the devices (command=‘5’), you would have to enter “~5~” to get the string.
Parameters
E
Rev A, January 2002
MHI-2000 Technical Reference Manual
E-39
Page 160
Appendix
E
Parameters
501 - 560 Inputs/Outputs Parameters 501
TRANSMIT DATA TRANSMIT DATA Valid Values
0 or 1
Default Value
0
Description
This parameter defines when to report barcode data during Presence. Table E–14 lists the TRANSMIT DATA valid values and their descriptions. TABLE E–14. TRANSMIT DATA Valid Values and Descriptions
E-40
Value
Description
0
Data is reported when the trailing edge of a box reaches the outzone
1
Data is presented with the leading edge of the box
MHI-2000 Technical Reference Manual
Rev A, January 2002