Page 121

E Parameters

APPENDIX E

The MHI-2000 reads stored parameter values from its internal memory in order to determine how it should operate. These values define most aspects of MHI-2000 operation, from the range of barcode symbologies that will be decoded, to what parity and checking schemes will be used to verify the integrity of received data. Parameters are combined into group setup strings, defined in Appendix A, “Group Setup Strings,” such that they can be conveniently uploaded and downloaded to and from the MHI-2000, using the Starnode, Host or Terminal ports.

E Parameters are organized into logical groups of closely related functions, called regions, as follows: 002 - 027, Operation Group 100 - 113, Host Port Group 120 - 133, Terminal Port Group 140 - 150, Setup Port Group 160 - 173, Port D Group 200 - 204, BIN 1 Decoding Group 210 - 214, BIN 2 Decoding Group 220 - 224, BIN 3 Decoding Group 230 - 234, BIN 4 Decoding Group 240 - 244, BIN 5 Decoding Group 250 - 254, BIN 6 Decoding Group 260 - 264, BIN 7 Decoding Group 270 - 274, BIN 8 Decoding Group 400 - 404, Starnode Setup Group 501 - 524, Inputs/Outputs Group

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-1

Parameters

Parameter Regions

Page 122

Appendix

E

Parameters

553 - 560, Relay Hold Time Group 600 - 602, User Program Group 610 - 625, User Variable Group 630 - 639, User String Groups 640 - 647, Ethernet Card 1 Group 650 - 657, Ethernet Card 2 Group 660 - 668, TCP/Networking Group 670 - 687, TCP/Network 1 and TCP/Network 2 Group 690 - 697, TCP/Network 3 Group 700 - 706, Tracking

Quick Reference List of Parameters by Region 002-027 - Operation Parameters TABLE E–1. Operations Parameters

Param

Function

Valid Values

Default Value

002

OPERATION MODE

0-4

0

003

IO MODE

0 - 4095

0000

006

DEBUG DATA

0 - 32767

00000

007

DEBUG DATA PORT

0 - 4095

0000

011

NO READ CHAR

001 - 122

063 ( ? )

012

LABEL SEPARATOR

001 - 122

044 ( , )

013

MULTI READ CHAR

001 - 122

035 ( # )

027

TUNNEL MULTI READS

0 or 1

0

100-173 - 1xx Serial Communication Parameters TABLE E–2. 1xx Serial Communication Parameters

E-2

Param

Function

Valid Values

Default Value

100

BAUD RATE HOST

0 - 11

07 (9600 bps)

101

DATA BITS HOST

7 or 8

8

102

PARITY HOST

2-4

4

103

STOP BITS HOST

1 or 2

1

104

FLOW CONTROL HOST

0-3

0

105

IN PRE. HOST

000 - 255

000

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 123

Quick Reference List of Parameters by Region

TABLE E–2. 1xx Serial Communication Parameters (Continued)

IN SUF. HOST

000 - 255

000

107

OUT PRE. HOST

000 - 255

000

108

OUT SUF. 1 HOST

000 - 255

128 ( CR-LF )

109

OUT SUF. 2 HOST

000 - 255

000

110

ERROR HOST

000 - 255

000

111

PROTOCOL HOST

0 - 10

00

112

PROTOCOL ADDR HOST

0 - 65536

00000

113

HARDWARE OPTS HOST

0 or 1

0

120

BAUD RATE TERM

0 - 11

07 (9600 bps)

121

DATA BITS TERM

7 or 8

8

122

PARITY TERM

2-4

4

123

STOP BITS TERM

1 or 2

1

124

FLOW CONTROL TERM

0-3

0

125

IN PRE. TERM

000 - 255

000

126

IN SUF. TERM

000 - 255

000

127

OUT PRE. TERM

000 - 255

000

128

OUT SUF. 1 TERM

000 - 255

128 ( CR-LF )

129

OUT SUF. 2 TERM

000 - 255

000

130

ERROR TERM

000 - 255

000

131

PROTOCOL TERM

0 - 10

00

132

PROTOCOL ADDR TERM

0 - 65536

00000

133

HARDWARE OPTS TERM

0

0

140

BAUD RATE SETUP

0 - 11

09

141

DATA BITS SETUP

7 or 8

8

142

PARITY SETUP

2-4

4

143

STOP BITS SETUP

1 or 2

1

144

FLOW CONTROL SETUP

0-3

0

145

IN PRE. SETUP

000 - 255

000

146

IN SUF. SETUP

000 - 255

000

147

OUT PRE. SETUP

000 - 255

000

148

OUT SUF. 1 SETUP

000 - 255

128 ( CR-LF )

149

OUT SUF. 2 SETUP

000 - 255

000

150

ERROR SETUP

000 - 255

000

160

BAUD RATE D-PORT

0 - 11

07

161

DATA BITS D-PORT

7 or 8

8

162

PARITY D-PORT

2-4

4

163

STOP BITS D-PORT

1 or 2

1

164

FLOW CONTROL D-PORT

0-3

0

165

IN PRE. D-PORT

000 - 255

000

166

IN SUF. D-PORT

000 - 255

000

Rev A, January 2002

MHI-2000 Technical Reference Manual

E Parameters

106

E-3

Page 124

Appendix

E

Parameters

TABLE E–2. 1xx Serial Communication Parameters (Continued)

167

OUT PRE. D-PORT

000 - 255

000

168

OUT SUF. 1 D-PORT

000 - 255

128 ( CR-LF )

169

OUT SUF. 2 D-PORT

000 - 255

000

170

ERROR D-PORT

000 - 255

000

171

PROTOCOL DPORT

0 - 10

00

172

PROTOCOL ADDR DPORT

0 - 65536

00000

173

HARDWARE OPTS DPORT

0

0

200-273 - BIN x Decoding Group Parameters TABLE E–3. BIN x Decoding Group Parameters

E-4

Param

Function

Valid Values

Default Value

200

BIN 1 SYMBOLOGY

00, 10, 20 or 50

10

201

BIN 1 MIN LENGTH

0 - 64

00

202

BIN 1 MAX LENGTH

0 - 64

00

203

BIN 1 CHAR POS

0 or 1

0

204

BIN 1 CHAR CHECK

ASCII string

NONE

210

BIN 2 SYMBOLOGY

00, 10, 20 or 50

00

211

BIN 2 MIN LENGTH

0 - 64

00

212

BIN 2 MAX LENGTH

0 - 64

00

213

BIN 2 CHAR POS

0 or 1

0

214

BIN 2 CHAR CHECK

ASCII string

NONE

220

BIN 3 SYMBOLOGY

00, 10, 20 or 50

00

221

BIN 3 MIN LENGTH

0 - 64

00

222

BIN 3 MAX LENGTH

0 - 64

00

223

BIN 3 CHAR POS

0 or 1

0

224

BIN 3 CHAR CHECK

ASCII string

NONE

230

BIN 4 SYMBOLOGY

00, 10, 20 or 50

00

231

BIN 4 MIN LENGTH

0 - 64

00

232

BIN 4 MAX LENGTH

0 - 64

00

233

BIN 4 CHAR POS

0 or 1

0

234

BIN 4 CHAR CHECK

ASCII string

NONE

240

BIN 5 SYMBOLOGY

00, 10, 20 or 50

00

241

BIN 5 MIN LENGTH

0 - 64

00

242

BIN 5 MAX LENGTH

0 - 64

00

243

BIN 5 CHAR POS

0 or 1

0

244

BIN 5 CHAR CHECK

ASCII string

NONE

250

BIN 6 SYMBOLOGY

00, 10, 20 or 50

00

251

BIN 6 MIN LENGTH

0 - 64

00

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 125

Quick Reference List of Parameters by Region

TABLE E–3. BIN x Decoding Group Parameters (Continued)

252

BIN 6 MAX LENGTH

0 - 64

00

253

BIN 6 CHAR POS

0 or 1

0

254

BIN 6 CHAR CHECK

ASCII string

NONE

260

BIN 7 SYMBOLOGY

00, 10, 20 or 50

00

261

BIN 7 MIN LENGTH

0 - 64

00

262

BIN 7 MAX LENGTH

0 - 64

00

263

BIN 7 CHAR POS

0 or 1

0

264

BIN 7 CHAR CHECK

ASCII string

NONE

270

BIN 8 SYMBOLOGY

00, 10, 20 or 50

00

271

BIN 8 MIN LENGTH

0 - 64

00

272

BIN 8 MAX LENGTH

0 - 64

00

273

BIN 8 CHAR POS

0 or 1

0

274

BIN 8 CHAR CHECK

ASCII string

NONE

400-404 - Starnode Setup Parameters

E

Param

Function

Valid Values

Default Value

400

STARNODE PROTOCOL

0 or 7

0

401

TERM. NUMBER

0 - 4095

0000 (none)

402

TERM. TYPE

0 - 126

000 (none)

403

MSG CHAR PREFIX

032 - 126

126 ( ~ )

404

MSG CHAR SUFFIX

032 - 126

126 ( ~ )

Parameters

TABLE E–4. Starnode Setup Parameters

501-560 - Inputs/Outputs Parameters TABLE E–5. Inputs/Outputs Parameters

Param

Function

Valid Values

Default Value

501

TRANSMIT DATA

0 or 1

0

503

INZONE TRIGGER

0 or 1

1

504

OUTZONE TRIGGER

0 or 1

1

505

ZONE ERROR CHAR 1

000 - 255

042 ( * )

506

ZONE ERROR CHAR 2

000 - 255

063 ( ? )

510

INZONE DEBOUNCE

0 - 255

020 ms

511

OUTZONE DEBOUNCE

0 - 255

000 ms

512

INPUTS DEBOUNCE

0 - 255

020 ms

520

INPUT 4 TRIGGER

0 or 1

1

521

INPUT 5 TRIGGER

0 or 1

1

522

INPUT 6 TRIGGER

0 or 1

1

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-5

Page 126

Appendix

E

Parameters

TABLE E–5. Inputs/Outputs Parameters (Continued)

523

INPUT 7 TRIGGER

0 or 1

1

524

INPUT 8 TRIGGER

0 or 1

1

553

RELAY 1 HOLD TIME

0 - 9999

0000

554

RELAY 2 HOLD TIME

0 - 9999

0000

555

RELAY 3 HOLD TIME

0 - 9999

0000

556

RELAY 4 HOLD TIME

0 - 9999

0000

557

RELAY 5 HOLD TIME

0 - 9999

0000

558

RELAY 6 HOLD TIME

0 - 9999

0000

559

RELAY 7 HOLD TIME

0 - 9999

0000

560

RELAY 8 HOLD TIME

0 - 9999

0000

600-639 - User Program Parameters TABLE E–6. User Program Parameters

Param

Function

Valid Values

Default Value

600

USER STACK SIZE

2 - 32

02 (2 KB)

601

FILE SYSTEM SIZE

0 - 2560

0032

602

PROGRAM CONTROL

0-4

0

610

USER VARIABLE 1

0 - 65535

00000

“

“

“

“

625

USER VARIABLE 16

0 - 65535

00000

630

USER STRING 1

ASCII string

NONE

·

“

“

“

639

USER STRING 10

ASCII string

NONE

640-668 - Ethernet Parameters TABLE E–7. Ethernet Parameters

E-6

Param

Function

Valid Values

Default Value

640

NETWORK NAME 1

ASCII string

NONE

641

IP ADDRESS 1

X.X.X.X

10.6.1.210

642

SUBNET MASK 1

X.X.X.X

255.255.255.000

643

GATEWAY 1

X.X.X.X

10.6.1.1

645

BROADCAST 1

0 or 1

1

646

CONTROLLER OPTS 1

0 - 255

000

647

HARDWARE ADDRESS 1

Read Only

00:20:5a:xx:xx:xx

650

NETWORK NAME 2

ASCII string

NONE

651

IP ADDRESS 2

X.X.X.X

000.000.000.000

652

SUBNET MASK 2

X.X.X.X

255.255.255.000

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 127

Quick Reference List of Parameters by Region

TABLE E–7. Ethernet Parameters (Continued)

653

GATEWAY 2

X.X.X.X

000.000.000.000

655

BROADCAST 2

0 or 1

1

656

CONTROLLER OPTS 2

0 - 255

000

657

HARDWARE ADDRESS 2

Read Only

NONE

660

FTP IP ADDRESS

X.X.X.X

10.6.1.16

661

FTP LOGIN NAME

ASCII string operations

662

FTP LOGIN PASSWORD

ASCII string cimatrix

663

NETWORK LOGIN NAME

ASCII string cimatrix

664

NETWORK LOGIN PASS

ASCII string cimatrix

665

TELNET LOCAL OPTS

0 - 007

000

666

NAME BROADCAST PORT

0 - 65535

08509

667

TCP/IP KEEP ALIVE

5 - 20000

00060

668

TCP/IP CONNECT TIME

1 - 99

05

670-697 - TCP/IP Port Parameters

Param

Function

Valid Values

Default Value

670, 680, 690

NET x DEST IP

X.X.X.X

000.000.000.000

671, 681, 691

NET x LOCAL SOURCE

0-2

0

672, 682, 692

NET x PORT

0 - 65535

08510

673, 683, 693

NET x PROTOCOL

0 or 7

0

674, 684, 694

NET x MSG PREFIX

000 - 255

002 (STX)

675, 685, 695

NET x MSG SUFFIX

000 - 255

003 (ETX)

676, 686, 696

NET x MSG CHAR

000 - 255

126 ( ~ )

677, 687, 697

NET x OPTIONS

0 - 63

001

700-706 - Tracking Parameters TABLE E–9. Tracking Parameters

Param

Function

Valid Values

Default Value

700

TRACKING

0 or 1

0 (disabled)

701

MILS/TIC

0 - 999 (x 0.001")

000 (disabled)

702

FIXED CONV SPEED

0 - 999 (feet per minute)

000 (off)

703

BOX TOLERANCE

0 - 999 (tenths of an inch)

040 (4.0")

704

FIXED BOX LENGTH

0 - 999 (tenths of an inch)

000 (off)

705

INZONE TO DATA

0 - 9999 (tenths of an inch)

0170 (17.0")

706

OUTZONE TO DATA

0 - 9999 (tenths of an inch)

0170 (17.0")

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-7

Parameters

E

TABLE E–8. TCP/IP Port Parameters

Page 128

Appendix

E

Parameters

002 - 027 Decoding & Operation Parameters 002

OPERATION MODE MODE OF OPERATION Valid Values

0-4 0, HOT READ MODE (default) Reports label when label threshold is met. Labels are binned and like labels are grouped together. When a bin count exceeds the label threshold, it is reported. 1, OUTZONE Reports label when triggered by an outzone event. All bins are analyzed with respect to the histogram parameters and a label or no read is reported for each bin. 2, INZONE/OUTZONE Reports label when triggered by an outzone event as in Outzone mode. Without gap tracking enabled, labels are not binned until an Inzone event occurs. In Gap Tracking, labels are placed on objects being tracked through the zone. 3, VIRTUAL OUTZONE Reports label when package tracking moves an object outside of the scan zone. Labels are placed on objects being tracked through the zone. 4, TIMEOUT Reports label at periodic intervals.

E-8

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 129

002 - 027 Decoding & Operation Parameters

003

IO MODE INPUT/OUTPUT MODE Valid Values

0 - 4095 To select a mode of operation, sum the following option codes: Add 1, Disable barcode data sent to TERMINAL port Add 2, Disable barcode data sent to HOST port Add 16, Disable beeper Add 64, Disable barcode data sent to STARNODE port Add 128, Disable barcode data sent to SETUP port Add 256, Disable barcode data sent to TCP1 port Add 512, Disable barcode data sent to TCP2 port Add 1024, Disable barcode data sent to TCP3 port

Default Value

0000 (all normal I/O enabled)

Description

Disabling ports that are not needed can increase the rate at which barcode data can be processed. In high-speed scanning applications, some I/O functions are not needed. Therefore, the ability to enable/disable specific I/O functions is desirable. If a user C program is running, it can control all communication ports. You can disable sign-on and other unsolicited messages that would normally be sent from the SETUP port in the Setup/Diagnostics mode. These messages could confuse a host computer or another device if it is connected to this serial port instead of to the HOST serial port. You can disable these messages by adding +128. This will not disable the automatic sending of decoded barcodes to the port in normal operation (i.e., not running a C program and not in the Setup/Diagnostic menu).

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-9

Parameters

E

Add 2048, Disable barcode data sent to TELNET port

Page 130

Appendix

006

E

Parameters

DEBUG DATA DEBUG DATA Valid Values

0 - 32767 To display other types of debug data, sum the following option codes: Add 1, Add label placement information Add 2, Add tracking zone errors Add 4, Add box length Add 8, Add box height Add 16, Add label replacement Add 32, Add label reading Add 64, Add bin dump Add 128, Add bin reject Add 256, Add tunnel master Add 512, Add tracking data Add 1024, Add Crisplant data Add 2048, Add PC tunnel data Add 4096, Add focusing data Add 8192, Add time stamp data Add 16384, Add TCP/IP data

E-10

Default Value

00000 (No debug data enabled)

Description

This parameter is used to select formatted diagnostic information for display.

MHI-2000 Technical Reference Manual

Rev A, January 2002