Page 117
D Modem Installation
APPENDIX D
Introduction
Parts List Verify the contents of your modem with the parts list in Table D–1. TABLE D–1. Modem Parts List
Quantity 1
Description
Part Number
56k Data/Fax Modem
Part # 971-0165-1
1
Scanner - Modem Interface Cable (9 to 25 pin)
Part # A1-62785-4
2
Locking fastener pad (Velcro Tape) for vertical mounting
Part # A4-66312-2
Site Preparation SICK Auto Ident, Inc. requests the customer to provide the following: 1.
Provide and set up a dedicated analog (conventional) telephone line.
2.
Provide a standard 120 VAC outlet.
3.
Provide a location to mount the modem within 25 feet of the scanner.
4.
Mount the modem in an easily accessible location to provide access for troubleshooting.
Locating & Mounting Modem You must locate the modem within five feet of a 120VAC power outlet and an appropriate telephone wall outlet, and within 25 feet of the scanner. The modem is designed for horizontal mounting. If you need to mount the modem vertically, a Locking Fastener Pad (Velcro tape) is provided.
Rev A, January 2002
MHI-2000 Technical Reference Manual
D-1
D Modem Installation
For diagnostic and troubleshooting help, you can connect your scanner to a modem through the Setup port. This modem connection allows remote site analysis via telephone lines. Also, you can use the modem to transmit the scanner data output directly to customer support personnel at SICK Auto Ident, Inc.
Page 118
Appendix
D
Modem Installation
Installation The SETUP Port on the scanner, the SICK Auto Ident, Inc.-supplied cable, and the serial port on the modem must use the same three communication lines: transmit, receive, and ground. Refer to Figure D–1 and Figure D–2. FIGURE D–1. Cabling Diagram
Scanner-Modem
FIGURE D–2. Modem Unit Connections
Power Power Connector (to Transformer)
RS232
Phone Line
DB25
RJ11/PSTN Connection RJ11/Phone Connection
1.
Ensure that all power is Off to the scanner and modem.
2.
Connect all cabling as shown in Figure D–1, Figure D–2, and as follows: a.
Connect the DB-25 Connector of the Scanner-Modem Interface Cable to the Modem Unit connector, RS-232C. Connect the DB-9Connector to the Setup Port on the scanner.
b.
Connect the wire from the AC Adapter to DC connector on the Modem Unit.
c.
Plug the AC adapter/power supply into a 120 VAC wall outlet. Note: The primary AC power for the modem and scanner must not be on the same circuit as heavy transient loads, such as motors or heavy machinery.
d.
Connect one end of the Telephone Extension Cable to LINE on the Modem Unit. WARNING! DO NOT CONNECT THE TELEPHONE LINE FROM THE WALL SOCKET TO THE MODEM CONNECTOR MARKED PHONE. THIS CAN PERMANENTLY DAMAGE THE MODEM.
D-2
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 119
Introduction
3.
e.
Connect the other end of the Telephone Extension Cable to your wall phone outlet.
f.
Connect the cable from your phone set to PHONE on the Modem Unit.
Power On the scanner and modem individually.
Modem Operation The Modem Units front panel LEDs indicate readiness for communication and data flow. The fourth LED (56) from the left should remain On after power-up.
Final Testing Final testing of the modem installation is to be performed by SICK Auto Ident, Inc. Technical Support personnel. Contact SICK Auto Ident, Inc. Technical Support.
D
•
Your company’s name and address.
•
A contact name and phone number.
•
The scanner’s serial number (located on the connector panel).
•
The scanner modem phone number.
Modem Installation
Note: Please have the following information before calling SICK Auto Ident, Inc. Customer Support.
Configuring Modem The Modem Unit is configured at the factory for your application. To reconfigure the modem, ensure you have a 9 or 25 pin serial RS-232 shielded modem cable. The baud rate of the PC should be 38.4k baud. Note: This cable is NOT supplied by SICK Auto Ident, Inc. To reset the configuration, follow the procedure below: 1.
Apply power to the Modem.
2.
Type ATZ and press Enter to check communication between the modem and scanner.
3.
Type AT&F0 and press Enter to restore the modem’s factory defaults.
4.
Type AT&K4 and press Enter to enable XON/XOFF flow control. Note: It is not possible to send commands to the scanner through the modem without performing Step 4. The scanner does not set the appropriate control signals.
5.
Type AT&D3 and press Enter to enable DTR.
6.
Type AT$SB38400 and press Enter to change the baud rate of the RS-232 port to 38.4k baud.
Rev A, January 2002
MHI-2000 Technical Reference Manual
D-3
Page 120
Appendix
D-4
D
Modem Installation
7.
Type ATS0=1 and press Enter to set the modem to auto answer after 1 ring.
8.
Type AT&W0 and press Enter to save the current configuration in memory (non-volatile RAM). This configuration will be used on subsequent power-ups.
9.
Cycle power to the modem Off and On. LED (56) should remain On.
MHI-2000 Technical Reference Manual
Rev A, January 2002