The text of a manual · part 13 of 25
MHI-2000 Technical Reference Manual: APPENDIX A Group Setup Strings
Pages 97 to 106 of 207, from MHI-2000 Technical Reference Manual
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick MHI2000
Page 97
A Group Setup Strings
A Group Setup Strings
APPENDIX A
This appendix defines the group setup strings that are used to set up the MHI-2000 from a host computer. Each string is diagrammed to identify the parameters in the string by their positions.
Group Setup String Definitions TABLE A–1. Group Setup String Definitions
Region X
Group Y
Parameter
Parameters in Setup String
0
0
MHI-2000 OPERATION
002 - 007
0
1
MHI-2000 OUTPUT
011 - 013
0
2
MULTIREADS
027
1
0
HOST SERIAL PORT
100 - 113
1
2
TERM SERIAL PORT
120 - 133
1
4
SETUP SERIAL PORT
140 - 150
1
6
D-PORT SERIAL PORT
160 - 173
2
0
DECODE BIN 1
200 - 204
2
2
DECODE BIN 2
210 - 214
2
4
DECODE BIN 3
220 - 224
2
6
DECODE BIN 4
230 - 234
2
8
DECODE BIN 5
240 - 244
3
0
DECODE BIN 6
250 - 254
3
2
DECODE BIN 7
260 - 264
3
4
DECODE BIN 8
270 - 274
4
0
LAN PORT COMMS and MSGS
401 - 404
5
1
PRESENCE INPUTS, RELAY TYPES
501 - 524
5
5
RELAY HOLD TIMES
553 - 560
Rev A, January 2002
MHI-2000 Technical Reference Manual
A-1
Page 98
Appendix
A
Group Setup Strings
TABLE A–1. Group Setup String Definitions (Continued)
Region X
Group Y
Parameter
Parameters in Setup String
6
0
USER PROGRAM
600 - 602
6
1
USER VARIABLES
610 - 625
6
3
USER STRINGS 1 - 5
630 - 634
6
4
USER STRINGS 6 - 10
635 - 639
6
5
ETHERNET CARD 1
640 - 647
6
6
ETHERNET CARD 2
650 - 657
6
7
FTP/NETWORK OPTIONS
660 - 668
6
8
TCP/IP PORT 1 PORT 2
670 - 687
6
9
TCP/IP PORT 3
690 - 697
7
0
TRACKING
700 - 706
The region and group number make up the two digit number used in the upload and download commands. A leading 8 invokes an upload command, to set (change) one or more parameter values. A leading 9 invokes a download command, to permit parameter values to be reviewed. When you want to download a group of parameters for review, use the command %9XY, where: 9 = get parameters X = 0 through 8 for the general region Y = 0 through 9 for the particular group string in that region When you want to upload many parameters at once to set or modify their values, as when loading values according to a Keysheet, use the command %8XY, where: 8 = set parameters X = 0 through 8 for the general region Y = 0 through 9 for the particular string. When you want to set an individual parameter, use the command %PPPVVV, where: PPP = the three-digit parameter number VVV = the parameter value
Group Setup Parameter String Formats The default values for parameters are shown in these strings. Your application may require other parameter values.
A-2
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 99
MHI-2000 Operation Parameters 002-007 (%800) %800 0 0000 00000 0000 Debug Data Port Debug Data IO Mode Operation Mode
MHI-2000 Output Parameters 011-013 (%801) %801 063 044 035 Multi Read Character Label Separator No Read Character
Multireads Parameters 027 (%802) %802 0 Tunnel Multi Reads
Host, Terminal, Setup, D-Port Serial Communications Parameters 100-113 (%810) %810 07 8 4 1 0 000 000 000 128 000 000 00 00000 0 Hardware Host Protocol Addr Protocol Host Error Host Out Suf. 2 Host Out Suf. 1 Host Out Pre. Host In Suf. Host In Pre. Host Flow Control Host Stop Bits Host Parity Host Data Bits Host Baud Rate Host
Rev A, January 2002
MHI-2000 Technical Reference Manual
A Group Setup Strings
Group Setup Parameter String Formats
A-3
Page 100
Appendix
A
Group Setup Strings
Parameters 120-133 (%812) %812 07 8 4 1 0 000 000 000 128 000 000 00 00000 0 Hardware Term Protocol Addr Protocol Term Error Term Out Suf. 2 Term Out Suf. 1 Term Out Pre. Term In Suf. Term In Pre. Term Flow Control Term Stop Bits Term Parity Term Data Bits Term Baud Rate Term
Parameters 140-150 (%814) %814 09 8 4 1 0 000 000 000 128 000 000 Error Setup Out Suf. 2 Setup Out Suf. 1 Setup Out Pre. Setup In Suf. Setup In Pre. Setup Flow Control Setup Stop Bits Setup Parity Setup Data Bits Setup Baud Rate Setup
A-4
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 101
Parameters 160-173 (%816) %816 07 8 4 1 0 000 000 000 128 000 000 00 00000 0 Hardware D-Port Protocol Addr Protocol D-Port Error D-Port Out Suf. 2 D-Port Out Suf. 1 D-Port Out Pre. D-Port In Suf. D-Port In Pre. D-Port Flow Control D-Port Stop Bits D-Port Parity D-Port Data Bits D-Port Baud Rate D-Port
Decode Bins Parameters 200-204 (%820) Parameters 210-214 (%821) Parameters 220-224 (%822) Parameters 230-234 (%823) Parameters 240-244 (%824) Parameters 250-254 (%825) Parameters 260-264 (%826) Parameters 270-274 (%827) %820 %822 %824 %826 %828 %830 %832 %834
10 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
0 0 0 0 0 0 0 0
NONE NONE NONE NONE NONE NONE NONE NONE
Character Check Character Position Bin x Max Length Bin x Min Length Bin x Symbology 1
Rev A, January 2002
MHI-2000 Technical Reference Manual
A-5
A Group Setup Strings
Group Setup Parameter String Formats
Page 102
Appendix
A
Group Setup Strings
Lan Port Comms and Messages Parameters 401-404 (%840) %840 0000 000 126 126 Message Character Suffix Message Character Prefix Terminal Type Terminal Number
Presence Inputs & Relay Types Parameters 501-524 (%851) %851 0 1 1 042 063 020 000 020 1 1 1 1 1 Inputs8 Trig Inputs7 Trig Inputs6 Trig Inputs5 Trig Inputs4 Trig Inputs Debounce Outzone Debounce Inzone Debounce Zone Error Char 2 Zone Error Char 1 Outzone Trigger Inzone Trigger Transmit Data
Relay Hold Times Parameters 553-560 (%855) %855 0000 0000 0000 0000 0000 0000 0000 0000 Relay 8 Hold Time Relay 7 Hold Time Relay 6 Hold Time Relay 5 Hold Time Relay 4 Hold Time Relay 3 Hold Time Relay 2 Hold Time Relay 1 Hold Time
A-6
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 103
User Program Parameters 600-602 (%860) %860 02 0032 0 Program Control File System Size User Stack Size
User Variables Parameters 610-625 (%861) %861 x x x x x x x x x x x x x x x x User Variable 16 User Variable 15 User Variable 14 User Variable 13 User Variable 12 User Variable 11 User Variable 10 User Variable 9 User Variable 8 User Variable 7 User Variable 6 User Variable 5 User Variable 4 User Variable 3 User Variable 2 User Variable 1
User Strings Parameters 630-634 (%863) %863 NONE NONE NONE NONE NONE User String 5 User String 4 User String 3 User String 2 User String 1
Rev A, January 2002
A Group Setup Strings
Group Setup Parameter String Formats
MHI-2000 Technical Reference Manual
A-7
Page 104
Appendix
A
Group Setup Strings
Parameters 635-639 (%864) %864 NONE NONE NONE NONE NONE User String 10 User String 9 User String 8 User String 7 User String 6
Ethernet Card Parameters Parameters 640-647 (%865) %865 NONE x.x.x.x x.x.x.x x.x.x.x 1 000 00:20:5a:xx:xx:xx Hardware Address 1 Controller Options 1 Broadcast 1 Gateway 1 Subnet Mask 1 IP Address 1 Network Name 1 Parameters 650-657 (%866) %866 NONE x.x.x.x x.x.x.x x.x.x.x 1 000 NONE Hardware Address 2 Controller Options 2 Broadcast 2 Gateway 2 Subnet Mask 2 IP Address 2 Network Name 2
A-8
MHI-2000 Technical Reference Manual
Rev A, January 2002
Page 105
FTP/Network Options Parameters 660-668 (%867) %867 x.x.x.x aaa bbb ccc ddd 000 08509 00060 05 TCP/IP Connect Time TCP/IP Keep Alive Name Broadcast Port Telnet Local Options Network Login Password Network Login Name FTP Login Password FTP Login Name FTP IP Address
TCP/IP Ports Parameters 670-687 (%868) %868 x.x.x.x 0 08510 0 002 003 126 x.x.x.x 0 08510 0 002 003 126 001 001 Net 2 Options Net 1 Options Net 2 Msg Char Net 2 Msg Suffix Net 2 Msg Prefix Net 2 Protocol Net 2 Port Net 2 Local Source Net 2 Destination IP Net 1 Msg Char Net 1 Msg Suffix Net 1 Msg Prefix Net 1 Protocol Net 1 Port Net 1 Local Source Net 1 Destination IP
Rev A, January 2002
MHI-2000 Technical Reference Manual
A-9
A Group Setup Strings
Group Setup Parameter String Formats
Page 106
Appendix
A
Group Setup Strings
Parameters 690-697 (%869) %869 x.x.x.x 0 08510 0 002 003 126 001 Net 3 Options Net 3 Msg Char Net 3 Msg Suffix Net 3 Msg Prefix Net 3 Protocol Net 3 Port Net 3 Local Source Net 3 Destination IP
Tracking Parameter 700-706 (%870) %870 0 000 000 040 000 0170 0170 Outzone to Data Inzone to Data
Fixed Box Length Box Tolerance Fixed Conv Speed Mils/Tic Tracking
A-10
MHI-2000 Technical Reference Manual
Rev A, January 2002