Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 24 of 25

MHI-2000 Technical Reference Manual: APPENDIX E Parameters, pages 191 to 200

Pages 191 to 200 of 207, from MHI-2000 Technical Reference Manual

The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick MHI2000

Page 191

640 - 697 Ethernet Network Parameters

677 687 697

NET 1 OPTIONS NET 2 OPTIONS NET 3 OPTIONS NETWORK x OPTIONS Valid Values

Decimal 0 - 063

Default Value

001

Description

These parameters for each network connection (1,2,3) are bit mappable settings with the following meanings: TABLE E–22. Values and Descriptions

Rev A, January 2002

Description

Keep Alive (0x01)

Setting this option to a 1 enables the keep alive for this socket.

Large Buffers (0x02)

Setting this option to a 1 doubles the sockets send and receive buffer size.

Don't Route (0x04)

Enabling this option allows outgoing messages to bypass the standard routing.

Linger (0x08)

Enabling this option allows any buffered data to be transmitted (if possible) prior to closing the socket. If Linger is disabled, buffered data may not be transmitted when a socket close request is issued.

No Delay (0x10)

This option is used to prevent data transmissions from being delayed by the TCP/IP stack.

Debug (0x20)

This option enables various debug features. It is intended for use by our Engineers and should not be enabled.

MHI-2000 Technical Reference Manual

E-71

E Parameters

Value

Page 192

Appendix

E

Parameters

700 - 706 Tracking Parameters TRACKING PARAMETERS With information provided by the Setup parameters, and inputs from such external devices as photoeyes and a tachometer, the lengths and y-axis positions of all boxes in the scan zone will be known by the device. When detected by a scan, the y-axis positions of all barcodes in the scan zone will also be known by the scanner. With this information, the scanner can correctly associate barcodes with their corresponding boxes. The parameters in this section define the following: 1.

The scanner’s position relative to the conveyor.

2.

The width of the conveyor.

3.

The maximum and minimum heights of boxes on the conveyor.

4.

Whether only one or multiple boxes at a time must be tracked through the scan zone.

5.

The positions of the photoeyes that sense boxes entering and leaving the scan zone.

6.

The number of height-sensing photoeyes.

7.

The positions of the height-sensing photoeyes.

8.

The distance per tachometer pulse that the conveyor and boxes move.

9.

The tolerances to be applied to allow for expected inaccuracies in measurements.

10.

The rotation angle of the scanner with respect to the conveyor.

11.

The laser X-pattern in use.

12.

The alternate CIX parameters in use.

13.

The length of boxes, if fixed.

14.

The conveyor speed, if fixed and a tachometer is not used.

The scan zone is normally defined by the positions of inzone and outzone photoeyes. These photoeyes will normally be positioned just outside of the boundaries within which the scanning beam can read barcodes on boxes as they pass by. In some applications, a single inzone photoeye and a tachometer can be used to define the scan zone. The minimum distance between inzone and outzone photoeyes must be increased as conveyor width increases, to compensate for the increased height-of-scan with increased reading range. Your keysheet will specify the minimum distances between these photoeyes for your application. The distance between zone-defining photoeyes may also be increased, if necessary, to accommodate conveyor physical positioning limitations or the special requirements of your application. For example, because data transmission of the barcode of a box normally occurs after the box has passed the outzone photoeye, moving the outzone photoeye farther downstream from

E-72

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 193

700 - 706 Tracking Parameters the scanner will cause a corresponding delay in data transmission. Such a data transmission delay may be needed by some sorting systems. If there will never be more than one box at a time in the scan zone, gap tracking need not be used, and no additional inputs other than the inzone and outzone photoeyes will be needed. If gap tracking is not used, and if multiple boxes enter the scan zone, the scanner may associate a barcode with the wrong box. However, the scanner can usually detect multiple boxes in the scan zone because inputs from the inzone and outzone photoeyes will occur out of their normal sequence. If this should occur, the scanner can append specific error characters to the data transmitted when a box passes the outzone photoeye. These extra characters can alert the host computer or tracking system to the possible error. The characters indicate whether multiple inzone inputs have occurred without the expected corresponding outzone inputs, or the reverse. Parameters 505 and 506 are used to select the characters. They will be sent only if gap tracking is disabled. When more than one box may be in the scan zone at one time, a tachometer is usually used to track box position through the zone, although tachometer-less tracking can also be implemented in some applications. In either case, the scanner must know how far the box will move for each pulse received from the tachometer or from the system clock if tachometer-less tracking is implemented.

Tolerances must be entered to allow for expected variations in box movement between the inzone to the outzone photoeyes. If actual box movement falls outside of these expected tolerances, the boxes will be considered false or phantom, and any barcode data read from these boxes will be discarded. Usually, these phantom boxes are not caused by real boxes but by unexpected occurrences, such as a maintenance person unintentionally blocking a photoeye. A maximum of eight boxes can be tracked between the inzone and outzone photoeyes. Be sure to check that the total number of small boxes and expected gaps between them, when placed end to end between these photoeyes, will not exceed this limit. With gap tracking invoked, you must enter parameters for conveyor width, the installed scanner height above the conveyor, and the heights of the shortest and tallest boxes. If the gap between boxes may be less than the difference in heights of the shortest and tallest boxes, height-sensing photoeyes must be used to provide box height information to the scanner. The scanner must know the height of the box being scanned to know whether the barcode being read is near an edge of a tall box or on a leading or trailing short box. The photoeyes are placed in a vertical array just before the inzone photoeye. The spacing between these height-sensing photoeyes must be less than the smallest inter-box gap. The height of each photoeye above the conveyor must be entered into the Setup parameters. This information, with the minimum and maximum box heights, provides the information needed to properly associate barcodes with closely spaced boxes of differing heights. When it is necessary to have very accurate barcode location information - for instance, because of short gaps between boxes - or when reading multiple closely spaced barcodes per box, using the maximum possible number of closely spaced height-sensing photoeyes is advisable.

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-73

E Parameters

You must enter the distances from the scanner’s center line (projected on to the plane of the conveyor) to the inzone and outzone photoeyes. After the distances are entered, the TACH CALIBRATION diagnostic test can be run to derive and enter the distance-per-pulse value automatically, if a tachometer is being used. Otherwise, a fixed conveyor speed must be entered.

Page 194

Appendix

E

Parameters

The same parameters that determine the minimum gap between boxes also determine the minimum gap between barcodes. The two dimensions are similar and the calculations are equally affected by the number of height-sensing photoeyes, the tachometer resolution and the care with which all measurements of the gap tracking parameters are made and entered. The minimum spacing between barcodes is typically eight inches, but smaller spacing may be possible, depending on the application. Because the positions and heights provided by the photoeyes will not be exact, boxes may appear to be taller or shorter than their actual heights. Using smaller numbers of widely spaced heightsensing photoeyes increases the uncertainty. Because of the uncertainty, barcodes positioned near the leading or trailing edges of boxes may appear to be off the box when read, and would normally be discarded, except that a box tolerance parameter is provided. The box tolerance parameter makes each box appear longer by the amount of the tolerance, allowing the scanner to compensate for the inexact input data. When short gaps between boxes are expected, this tolerance must be chosen carefully such that box lengths are not increased so much that the gap between boxes effectively disappears. If this happens, barcodes that could be associated with two boxes will be associated with the first box. When using large box tolerance values, the inzone and outzone photoeyes may also have to be moved away from the scanner by a corresponding amount. This will allow the scanner to make use of the selected tolerance for barcodes at the edges of boxes as the boxes enter or exit the scan zone.

E-74

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 195

700 - 706 Tracking Parameters

700

TRACKING TRACKING Valid Values

0 or 1 0, Disabled 1, Enabled

Default Value

0

Description

This parameter indicates the tracking function.

Parameters

E

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-75

Page 196

Appendix

701

E

Parameters

MILS/TIC TRACKING, IN MILS Valid Values

0 - 999

Default Value

000 (Gap Tracking disabled)

Description

This parameter specifies the tachometer resolution expressed in distance traveled by the conveyor per one encoder pulse. The value of this parameter can be easily and accurately measured by running the TACH CALIBRATION routine included in the device diagnostic menu described in “Diagnostic Tests & Procedures” in your device’s Technical Reference Manual. An initial estimate of the value must be entered before running the TACH CALIBRATION routine. A value of 050 is typical. The value of this parameter can also be calculated by analyzing the conveyor drive system from the point where the tachometer is coupled to it to the conveyor belt or rollers in through the scan zone. The tachometer typically outputs 300 pulses per revolution. Some applications don’t need to use gap tracking, but do need to perform actions in a user program according to distance traveled. The tachometer may be used by a user program if parameter 702 FIXED CONV SPEED is non-zero, even if gap tracking is disabled by setting parameter 700 TRACKING to 0.

E-76

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 197

700 - 706 Tracking Parameters

702

FIXED CONV SPEED FIXED CONVEYOR SPEED Valid Values

000 - 999 (feet per minute)

Default Value

000 (Disabled)

Description

Normally, a tachometer is used to measure the movement of the conveyor during gap tracking operations. If this parameter has a non-zero value entered, the value will be used as the assumed conveyor speed, to provide tachometer-less gap tracking. Conveyor starts and stops cannot be recognized when using this technique. The device will assume that the conveyor is always running. For this reason, use of an actual tachometer is recommended. When invoking tachometer-less gap tracking, set this parameter to 001.

E Parameters

When a fixed conveyor speed is being used, scanner input 3, normally reserved for the tachometer, is available for general purpose use.

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-77

Page 198

Appendix

703

E

Parameters

BOX TOLERANCE BOX TOLERANCE Valid Values

0 - 999 (tenths of an inch)

Default Value

040 (4.0")

Description

Box tolerance is a dimensional tolerance applied to a box to increase its length to allow for measuring uncertainty. This parameter is useful when close tolerances are required for small gaps. A loose tolerance is required to eliminate false multireads. If the position of a barcode is calculated to be within the increased length, the barcode will be associated with the box. The default value of 040 provides a 4.0” area before and after each box within which a barcode will be considered to be on the box. This tolerance value requires that there be a minimum gap of 4.0” (2 x 4”) between boxes.

E-78

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 199

700 - 706 Tracking Parameters

704

FIXED BOX LENGTH FIXED BOX LENGTH Valid Values

0 - 999 (tenths of an inch)

Default Value

000 (Disabled)

Description

Normally, the length of a box is determined by measuring the distance that it travels while blocking the inzone photoeye. This parameter can be used to define a fixed box length for use in gap tracking in applications where the inzone signal durations generated are not proportional to the lengths of the boxes. In tilt-tray applications, for example, the inzone may be detected by a photoeye mounted underneath the trays, blocked by the car or other mechanism, which gives a short pulse. If this parameter is non-zero, that value will be used for the box length instead of the duration of the inzone signal.

Parameters

E

Rev A, January 2002

MHI-2000 Technical Reference Manual

E-79

Page 200

Appendix

705 706

E

Parameters

INZONE TO DATA OUTZONE TO DATA INZONE TO DATA, OUTZONE TO DATA

E-80

Valid Values

0 - 9999 (tenths of an inch)

Default Value

0170 (17.0")

Description

These parameters specify the distance between the inzone and outzone Presence photoeyes and the centerline of the scan zone drawn perpendicular to conveyor motion on the plane of the conveyor.

MHI-2000 Technical Reference Manual

Rev A, January 2002