Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 25

MHI-2000 Technical Reference Manual: MHI-2000 Technical Reference Manual, pages 1 to 9

Pages 1 to 9 of 207, from MHI-2000 Technical Reference Manual

The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick MHI2000

Page 1

MHI-2000 Technical Reference Manual

Rev A, January 2002

EM-63555-1A

Page 2

MHI-2000 Technical Reference Manual Rev A, January 2002

Copyright © 2002 SICK Auto Ident, Inc. This manual and the software described in it are copyrighted, with all rights reserved. Under the copyright laws, no part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form by any means, electronic, mechanical, by photocopying, recording, or otherwise, without prior written permission of SICK Auto Ident, Inc. Information furnished by SICK Auto Ident, Inc. is believed to be accurate and reliable and is subject to change without notice. However, no responsibility is assumed by SICK Auto Ident, Inc. for its use or any errors that may appear in this document, nor for any infringements of patents or other rights of third parties, which may result from its use. Factory Authorized Training SICK Auto Ident, Inc. provides comprehensive product training. Contact the SICK Auto Ident, Inc. Training Coordinator at 1-888-264-4641 for inhouse and on-site class schedules and rates.

Getting Assistance If you have questions or comments, please contact SICK Auto Ident, Inc. at 1-888-264-4641. For additional assistance, contact:

SICK Auto Ident, Inc. 5 Shawmut Road Canton, MA 02021 USA (781) 302-2500 Fax (781) 828-3150

•

Order Processing (Option #1)

•

Technical Support (Option #2)

•

Field Service Contracts (Option #3)

•

Customer Service Fax (781) 828-3150

Product names mentioned herein are for identification purposes only and may be trademarks and/or registered trademarks of their respective companies: OMNI, CiComm, CiFrame, CiMenu, CiMAX, CiPRO, CiBOS, Scanstar, Starnode, and TALL Other references to trademarks are the rights of their respective owners. Printed in the United States of America.

Page 3

Warning!

Warning!

WARNING! THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY ENERGY AND, IF NOT INSTALLED AND USED IN ACCORDANCE WITH THIS USER MANUAL, MAY CAUSE INTERFERENCE TO RADIO COMMUNICATIONS. IT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR CLASS A COMPUTING DEVICES PURSUANT TO SUBPART J OF PART 15 OF FCC RULES, WHICH ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST SUCH INTERFERENCE WHEN OPERATED IN A COMMERCIAL ENVIRONMENT. OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE INTERFERENCE, IN WHICH CASE THE USER, AT HIS OWN EXPENSE, MUST TAKE NECESSARY MEASURES TO CORRECT THE INTERFERENCE. THIS PRODUCT DOES NOT EXCEED THE CLASS A LIMITS FOR RADIO NOISE EMISSIONS FROM DIGITAL APPARATUS SET FORTH IN THE RADIO INTERFERENCE REGULATIONS OF THE CANADIAN DEPARTMENT OF COMMUNICATIONS. (LE PRÉSENT APPAREIL NUMÉRIQUE N'ÉMET PAS DE BRUITS RADIOÉLECTRIQUES DÉPASSANT LES LIMITES APPLICABLES AUX APPAREILS NUMÉRIQUES DE LA CLASS A PRESCRITES DANS LE RÈGLEMENT SUR LE BROUILLAGE RADIOÉLECTRIQUE ÉDICTÉ PAR LE MINISTÈRE DES COMMUNICATIONS DU CANADA.)

Caution - Use of controls or adjustments or performance of procedures other than those specified in this manual may result in hazardous exposure.

Attention - l’utilisation de procédures de contrôle, de reglage ou d’utilisation autres que celles specifiées dans ce manuel peut entrainer une exposition dangereuse à la lumière du laser.

Peligro - El uso de controles, ajustes o funcionamiento diferentes a los especificados en este manual pueden resultar en exposición a el rayo laser.

Waarschuwing - Afwijkend gedrag op de in net handboek beschreven procedure kan schok en/of bestralingsgevaar teweegbrengen.

Rev A, January 2002

MHI-2000 Technical Reference Manual iii

Page 4

Warning

Vorsicht: Veränderungen der Justierungen oder Einstellungen, sowie sonstige Veränderungen die nicht in diesem Manual beschrieben sind, können zu gefährlichen Ausstrahlungen führen.

Varoitus - Kaikki muut huolto ja säätötoimenpiteet, joita ei ole tässa ohjeessa määritelty tai maimittu, voivat aiheuttaa vaaratilanteen.

Attenzione - L’uso di controlli o tarature o l’asecuzione di procedure diverse da quelle specificate in questo manuale possono causare pericolose esposizioni. There are no operator serviceable parts/controls in the scanner. Refer service to factory-authorized dealer. Ne pas ouvrir - toute réparation effectuée par une personne non qualifiée peut entrainer la violation des règles de securité relatives au laser. Partes y/o controles del scanner que no se pueden manipular por el usuario. Contactar a el distribuidor autorizado. Reparable sólo en fábrica. Gelieve neit te openen - eigen veiligheid kan hierdoor in gevaar gebracht worden. Versuchen Sie nich selbst irgendwelche Reparaturen oder Einstellungen im Innern des Gerätes vorzunehmen. Da es innen kane vom Benutzer zu bedienenden Teile gibt, gefährdet an öffnen des Gehäuses nur Ihre Sicherheit. Raparaturen nur durch eine autorisierte Fachwerkstatt. Lukijan saa avata ja huoltaa vain maahantuojan valtuuttama korjaaja. L’utente finale non può effettuare interventi di riparazione sugli scanner. Rivolgersi esclusivamente al rivenditori autorizzati. I servizi di riparazione del produttore sono in USA. Caution - Danger of explosion if lithium battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of the used batteries according to the manufacturer’s instructions.

Attention danger d’explosion si pile lithium mal branchée - remplacer par pièce d’origine contrôlée - suivre les instructions du fabricant pour le recyclage des piles lithium usagées.

Peligro - Peligro de explosión si la batería de litio no se coloca correctamente. Reemplazaría únicamente con el mismo tipo o equivalente recomendado por el fabricante. Utilizar las baterías según las instrucciones del fabricante.

Waarschuwing - Ontploffingsgevarr bij foutieve vervanging batterij. Omwisseling uitsluitend door analoog en door de fabrikant goedgekeurd type. Teruggave batterijen volgens instructies de fabrikant.

iv

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 5

Warning

Vorsicht- Explosionsgefahr bei fehlerhaftem Austausch der Lithiumbatterie. Eventuellen Austausch nur mit gleichem oder kompatiblen, vom Hersteller empfohlenen Typ. Gebrauchte Batterien nur bei entsprechenden Sammelstellen entsorgen.

Varoitus - Räjähdysvaara jos litiumparisto asennataan väärin. Vaihda vain valmistajan suosittelemaan samaan tai vastaavaan paristotyyppiin. Hävitä paristo valmistajan ohjeiden mukaisesti.

Attenzione - Può esservi pericolo di esplosioni se le batterie al litio vengono sostituite in modo non corretto. Tali batterie devono essere sostituite unicamente con lo stesso tipo di batterie raccomandato dal produttore oppure con batterie di tipo equivalente. Le batterie usate devono essere smaltite seguendo le modalità raccomandate dal produttore.

Rev A, January 2002

MHI-2000 Technical Reference Manual v

Page 6

Warning vi

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 7

Contents

PREFACE

Welcome xv

How To Use This Manual xv

Guide Conventions xv Warning Symbols xvi

Getting Assistance xvii

SICK Auto Ident, Inc. Customer Service Policy xvii Return-to-Factory Instructions xvii Product Warranty xviii

CHAPTER 1

Overview & Maintenance

1–1

Overview 1–1 Typical Physical Setup 1-1 Keysheet 1-1 Software Updates 1-1

Specifications 1–2 MHI-2000 1-2 Configuration 1–2 Physical 1–2 Power 1–2 Construction 1–3 Environmental 1–3 LED Status Indicators 1–3 Communications 1–3 Inputs 1–3 Outputs 1–3

Maintenance 1–4

CHAPTER 2

Installation & Setup

2–1

Unpacking & Inspection 2–1 Installation Checklist 2–1 Site Preparation 2-2 Electrical Connections 2-2

Site Preparation

2–2

Power 2-2 Setup 2-2 Photoeyes & Tachometer Installation 2-2 Installing the Tachometer 2–3 Mounting Presence Photoeyes 2–4 Mounting Photoeye Tree Bracket 2–4

Rev A, January 2002

MHI-2000 Technical Reference Manual vii

Page 8

Contents CHAPTER 3

Controls, Connectors, & Indicators MHI-2000 I/O Panel

3–1

3–1

Power Input/ON-OFF Switch/Fuse Unit 3-1 Status Indicators 3-1 LEDs 3–2 Interface Board Connections 3-3 Control Input Connections 3-6 Interface Unit Inputs 3–6 Optional Input Relay Modules 3–7 Control Output Connections 3-7 Interface Unit Outputs 3–7 Optional Output Relay Modules 3–8 Programmable Interface Controller 3-9 Special Inputs & Outputs 3-10 Beep 3–10 Interface Board I/O Connections 3-10 Expansion Board Input Connections 3-11 Connectors on Front Panel 3-12 Auxiliary Connector 3–12 Starnode Connector 3–13 Setup Connector 3–13 Ethernet Connector 3–13 I/O Connector 3–13 50-Pin Cable Connector 3-15

CHAPTER 4

Startup & Operation

4–1

Serial Communications Ports 4–1 Power Up 4-1 User Interface - Parameters & Diagnostics 4-3 Operating Modes 4-3 Normal Mode 4–4 Setup & Diagnostic Modes 4–4 Resetting to Default Parameters 4–4 Non-Intelligent ASCII Terminal 4-4 Setup Menu on the ASCII Terminal 4–5 Data Entry Through Setup Menu on the ASCII Terminal 4–6 Diagnostics Menu Display on the ASCII Terminal 4–6 CiMAX 1400 Hand-Held Terminal 4-7 CiMAX 1400 Hand-Held Terminal Function Keys 4–8 Special-Use Alpha Keys on the CiMAX 1400 Hand-Held Terminal 4–8 Using the Hand-Held Terminal as a Real Time Display 4–9

CHAPTER 5

Host Commands & Downloads Introduction 5–1 Control Commands from the Host

5–1

5–1

ASCII 4 Command - Requesting a Diagnostic String 5-3 ASCII 5 Command - Requesting Status Information 5-4 Status String Digit Explanations 5–5 viii

MHI-2000 Technical Reference Manual

Rev A, January 2002

Page 9

Contents ASCII ; Command - Rebooting MHI-2000 5-7 ASCII < Command - Clearing Diagnostic Count 5-8 ASCII = Command - Enabling Relay Control Outputs 5-9 ASCII > Command - De-Energizing Relay Control Outputs 5-10 ASCII ? Command - Setup 5-11 Specific Control Commands 5–11 Uploading Multiple Group Commands 5–12 User Program Control Commands 5–13 ASCII % Command-Parameters 5-14 Individual Group String Commands 5–14 Individual Parameter Command 5–14 ASCII A or Greater Command - User Program Data 5-15 TOTAL Command 5-16 TOLER Command 5-17 TOT00 Command 5-18 ~!~ & ~$~ Commands 5-19 VER Commands 5-20

C Programming Considerations

5–21

Developing User Programs 5-21 Installing C Programming Platform 5–21 Overview of Development Steps 5-22 Creating a Program 5–23 Compiling a Program 5–23 Link & Locate a Program 5–24 Formatting for Downloads 5–25 Configuring the Target Device 5-25 Starnode Parameters 5–25 Ethernet Parameters 5–25 Serial Parameters 5–26 Loading Programs via RS-232 5-26 Loading Programs on Starnode via Starndem 5-27 Using Multidem to Load Programs 5-28 Overview 5–28 Send Program 5–28 Downloading .l2k Files - Starnode Asynchronous Cntlr MUX Interface 5–30

Data Detection by C 5–31 Polling 5-31 Event Manager 5-31

CHAPTER 6

Diagnostics

6–1

Introduction 6–1 Initiating Diagnostics Tests from a Terminal 6-1 Diagnostics Menu 6-2 Diagnostic Tests & Procedures 6-2 Stopping Diagnostic Tests 6–3 Input/Output (IO PORTS) Test 6–3 Tachometer Test 6–3 Tachometer Calibration Procedure 6–4 Keysheets 6–5 Operating System Update 6–6 Network Ping 6–7

Rev A, January 2002

MHI-2000 Technical Reference Manual ix