What is in it
The Product Reference Guide for the Wasp WLS9600, a handheld barcode reader with a laser scan engine. It covers unpacking and cable connection, choosing an interface (RS-232, USB-Com, keyboard, USB-OEM, wand emulation), and configuring the reader by scanning programming barcodes: data format, beeper and LED indicators, scan modes and the settings for each symbology. Appendices give technical specifications, factory defaults, sample barcodes, a keypad and scancode tables.
Its parts
- Introduction
- Setup
- Configuration Using Barcodes
- Laser Features
- References
From the manual
Key facts from this manual
Each line names its page in the PDF.
The Wasp WLS9600 1D Laser Scanner Product Reference Guide, a 306-page guide to connecting, programming and specifying the WLS9600 handheld laser scanner. It explains cable hookup, choosing the host interface, setting features by scanning programming barcodes, the laser options, indicator and error codes, and the factory defaults.
- Scanner type
- Handheld 1D scanner with a 650nm Class 2 laser p. 13, 269
- Interfaces
- RS-232 (Std, Wincor-Nixdorf, OPOS), USB Com, USB Keyboard (also Apple), USB OEM, keyboard wedge (AT, PS2, PC-XT, IBM terminals, Digital VT terminals) and wand emulation p. 270
- Power
- 5V±5%, 260 mA max; 2.5 mA in USB suspend; typical standby 30mA or less p. 269
- Depth of field
- 5 mil: 1.4" to 6.22"; 13 mil (EAN): 0.87" to 18.7"; 20 mil: up to 27.1" (to 69cm) p. 269, 270
- Scan angle
- 47° normal or 35° narrow p. 238, 269
- Resolution and contrast
- 4 mil minimum element width; 15% minimum reflectance p. 269
- Scan tolerances
- Roll ± 35°, pitch ± 50°, skew ± 65° p. 269
- Size and weight
- Height 7.1”/181 mm, length 3.9”/100 mm, width 2.8”/71 mm; about 6.0 ounces/169 g without cable p. 269
- Operating environment
- 32° to 122° F (0° to 50° C); 5% to 90% relative humidity, non-condensing p. 270
- Ruggedness
- 18 drops from 1.8 meters (5.9 feet) to concrete; IP52; 16 KV ESD; ambient light up to 100,000 Lux p. 270
- Symbologies
- UPC/EAN/JAN, P2/P5, ISBN/ISSN, Code 39 (Full ASCII, Italian Pharmacode, CIP), Code 128, GS1-128, C128 ISBT, I 2 of 5, Standard, Industrial and Follet 2 of 5, IATA, China Postal Code, Code 11, Plessey, Codabar, Code 93, MSI, GS1 DataBar, Code 4, Code 5, Codablock F p. 270
- Error codes
- LED flashes or beeps after a failed self-test: 1 configuration, 2 interface PCB, 4 reader module, 5 laser pointer, 6 digital PCB, 14 CPLD/code mismatch p. 273
- Default RS-232 settings
- 9600 baud, 8 data bits, 1 stop bit, no parity, RTS handshaking p. 275
- Scan modes
- Trigger Single (default), Trigger Hold Multiple, Trigger Pulse Multiple, Flashing, Always On p. 83
What this manual walks you through
- Connecting the RS-232, keyboard wedge or USB cable p. 16, 17
- Selecting the host interface by scanning one barcode p. 18, 19, 20, 21
- Programming features with the ENTER/EXIT programming barcodes p. 13, 26
- Restoring custom or factory (USA or EU) defaults p. 23
- Sending the software version to the host p. 22
- Choosing a scan mode, including flashing mode for stand use p. 83, 237
- Setting laser scan angle, idle mode, bi-directional decoding and always-on timeout p. 238, 239, 240
- Reading the LED, beeper and error code indications p. 272, 273
- Factory default settings for each interface p. 275, 276
Good to know
- Do not scan the ENTER/EXIT barcode before an interface selection barcode. p. 18
- The USB Com interface needs the USB Com driver downloaded from the Wasp website. p. 19
- Custom defaults depend on the interface, so set the interface before scanning Restore Custom Default Configuration. p. 23
- On RS-232, if the terminal cannot power the reader, use the approved AC adapter plugged into the cable connector. p. 16
- Some interfaces start the scanner disabled; to program it in that state, hold the trigger for five seconds. p. 18
Questions this manual answers
How do I reset the Wasp WLS9600 to factory settings?
Scan the Restore USA or Restore EU Factory Configuration barcode; both restore factory settings including the interface type, and differ only in label IDs. p. 23
What does a long tone at startup mean on the WLS9600?
The reader failed its self-test and entered FRU isolation mode; the count of LED flashes or beeps then names the fault, and the guide says to contact the helpdesk. p. 273
How do I remove the cable from a WLS9600 scanner?
Insert a paper clip into the release aperture in the handle, then unplug the cable. p. 16
What are the WLS9600 default serial settings?
9600 baud, 8 data bits, 1 stop bit, no parity, with RTS handshaking. p. 275
Which scan mode should I use with a stand?
Flashing mode is the one recommended for hands-free stand operation. p. 83
Contents
Chapters and sections
Each line opens the PDF at its page.
The whole text · 35 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 41-4
- Pages 5 to 65-6
- Pages 7 to 107-10
- Introduction11-14
- Setup15-24
- Configuration Using Barcodes, pages 25 to 3425-34
- Configuration Using Barcodes, pages 35 to 4435-44
- Configuration Using Barcodes, pages 45 to 5445-54
- Configuration Using Barcodes, pages 55 to 6455-64
- Configuration Using Barcodes, pages 65 to 7465-74
- Configuration Using Barcodes, pages 75 to 8475-84
- Configuration Using Barcodes, pages 85 to 9485-94
- Configuration Using Barcodes, pages 95 to 10495-104
- Configuration Using Barcodes, pages 105 to 114105-114
- Configuration Using Barcodes, pages 115 to 124115-124
- Configuration Using Barcodes, pages 125 to 134125-134
- Configuration Using Barcodes, pages 135 to 144135-144
- Configuration Using Barcodes, pages 145 to 154145-154
- Configuration Using Barcodes, pages 155 to 164155-164
- Configuration Using Barcodes, pages 165 to 174165-174
- Configuration Using Barcodes, pages 175 to 184175-184
- Configuration Using Barcodes, pages 185 to 194185-194
- Configuration Using Barcodes, pages 195 to 204195-204
- Configuration Using Barcodes, pages 205 to 214205-214
- Configuration Using Barcodes, pages 215 to 224215-224
- Configuration Using Barcodes, pages 225 to 234225-234
- Configuration Using Barcodes, pages 235 to 240235-240
- References, pages 241 to 250241-250
- References, pages 251 to 260251-260
- References, pages 261 to 268261-268
- Technical Specifications269-274
- Standard Defaults275-284
- Sample Barcodes285-288
- Keypad289-292