The text of a manual · part 14 of 35
WLS9600 1D Laser Scanner Product Reference Guide: Configuration Using Barcodes, pages 105 to 114
Pages 105 to 114 of 306, from WLS9600 1D Laser Scanner Product Reference Guide
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wasp WLS-9600
Page 105
ENTER/EXIT PROGRAMMING MODE
In-Store Minimum Reads
In-Store Minimum Reads This feature specifies the minimum number of consecutive times an in-store label must be decoded before it is accepted as good read. In-store labels are defined as UPC-A labels with a number-system character of 2 or 4 as well as EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 13 label starting with the three characters '980'.
In-Store Minimum Reads = 1
DEFAULT In-Store Minimum Reads = 2
In-Store Minimum Reads = 3
In-Store Minimum Reads = 4
Product Reference Guide
95
Page 106
Add-Ons
ENTER/EXIT PROGRAMMING MODE
ADD-ONS Contact Customer Support for advanced programming of optional and conditional add-ons.
Optional Add-ons The reader can be enabled to optionally read the following add-ons (supplementals): If a UPC/EAN base label and an add-on are both decoded, the reader will transmit the base label and add-on. If a UPC/EAN base label is decoded without an add-on, the base label will be transmitted without an add-on. Conditional add-on settings (if enabled) are considered by the reader before optional add-on settings.
DEFAULT Optional Add-Ons = Disable P2
Optional Add-Ons = Enable P2
DEFAULT Optional Add-Ons = Disable P5
Optional Add-Ons = Enable P5
DEFAULT Optional Add-Ons = Disable GS1-128
Optional Add-Ons = Enable GS1-128
96
WLS9600
Page 107
ENTER/EXIT PROGRAMMING MODE
Optional Add-On Timer
Optional Add-On Timer This option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled. (Also see "Optional GS1-128 Add-On Timer" on page 100.)
Optional Add-on Timer = 10ms
Optional Add-on Timer = 20ms
Optional Add-on Timer = 30ms
Optional Add-on Timer = 40ms
Optional Add-on Timer = 50ms
Product Reference Guide
97
Page 108
Add-Ons
ENTER/EXIT PROGRAMMING MODE
Optional Add-On Timer (continued)
Optional Add-on Timer = 60ms
DEFAULT Optional Add-on Timer = 70ms
Optional Add-on Timer = 100ms
Optional Add-on Timer = 120ms
Optional Add-on Timer = 140ms
Optional Add-on Timer = 160ms
98
WLS9600
Page 109
ENTER/EXIT PROGRAMMING MODE
Optional Add-On Timer
Optional Add-On Timer (continued)
Optional Add-on Timer = 180ms
Optional Add-on Timer = 200ms
Optional Add-on Timer = 220ms
Optional Add-on Timer = 240ms
Optional Add-on Timer = 260ms
Optional Add-on Timer = 280ms
Optional Add-on Timer = 300ms
Product Reference Guide
99
Page 110
Add-Ons
ENTER/EXIT PROGRAMMING MODE
Optional GS1-128 Add-On Timer This option sets the timer expiration value to read the added part after reading the linear EAN/ UPC part. For UPC/EAN add-ons other than those of that type, see "Optional Add-On Timer" on page 97.
DEFAULT Optional GS1-128 Add-On Timer = Disable
Optional GS1-128 Add-On Timer = 10ms
Optional GS1-128 Add-On Timer = 20ms
Optional GS1-128 Add-On Timer = 30ms
Optional GS1-128 Add-On Timer = 40ms
Optional GS1-128 Add-On Timer = 50ms
100
WLS9600
Page 111
ENTER/EXIT PROGRAMMING MODE
Optional GS1-128 Add-On Timer
Optional GS1-128 Add-On Timer (continued)
Optional GS1-128 Add-On Timer = 60ms
Optional GS1-128 Add-On Timer = 70ms
Optional GS1-128 Add-On Timer = 100ms
Optional GS1-128 Add-On Timer = 120ms
Optional GS1-128 Add-On Timer = 140ms
Optional GS1-128 Add-On Timer = 160ms
Product Reference Guide
101
Page 112
Add-Ons
ENTER/EXIT PROGRAMMING MODE
Optional GS1-128 Add-On Timer (continued)
Optional GS1-128 Add-On Timer = 180ms
Optional GS1-128 Add-On Timer = 200ms
Optional GS1-128 Add-On Timer = 220ms
Optional GS1-128 Add-On Timer = 240ms
Optional GS1-128 Add-On Timer = 260ms
Optional GS1-128 Add-On Timer = 280ms
Optional GS1-128 Add-On Timer = 300ms
102
WLS9600
Page 113
ENTER/EXIT PROGRAMMING MODE
P2 Add-Ons Minimum Reads
P2 Add-Ons Minimum Reads This feature specifies the minimum number of times a P2 add-on must be read before it is marked as valid and then combined with a base label.
P2 Add-Ons Minimum Reads = 1
DEFAULT P2 Add-Ons Minimum Reads = 2
P2 Add-Ons Minimum Reads = 3
P2 Add-Ons Minimum Reads = 4
Product Reference Guide
103
Page 114
Add-Ons
ENTER/EXIT PROGRAMMING MODE
P5 Add-Ons Minimum Reads This feature specifies the minimum number of times a P5 add-on must be read before it is marked as valid and then combined with a base label.
DEFAULT P5 Add-Ons Minimum Reads = 1
P5 Add-Ons Minimum Reads = 2
P5 Add-Ons Minimum Reads = 3
P5 Add-Ons Minimum Reads = 4
104
WLS9600