The text of a manual · part 11 of 35
WLS9600 1D Laser Scanner Product Reference Guide: Configuration Using Barcodes, pages 75 to 84
Pages 75 to 84 of 306, from WLS9600 1D Laser Scanner Product Reference Guide
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wasp WLS-9600
Page 75
READING PARAMETERS
DOUBLE READ TIMEOUT on page 66
GOOD READ BEEP VOLUME on page 71
LABEL GONE TIMEOUT on page 67
GOOD READ LED DURATION on page 72
POWER ON ALERT on page 68
SCAN MODE on page 73
GOOD READ: WHEN TO INDICATE on page 68 SCANNING ACTIVE TIME on page 74 GOOD READ BEEP TYPE on page 69
FLASH ON TIME on page 74
GOOD READ BEEP FREQUENCY on page 69
FLASH OFF TIME on page 75
GOOD READ BEEP LENGTH on page 70
GREEN SPOT DURATION on page 75
Product Reference Guide
65
Page 76
ENTER/EXIT PROGRAMMING MODE
Double Read Timeout Double Read Timeout prevents a double read of the same label by setting the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the specified timeout, the second read is ignored. Double Read Timeout does not apply to scan modes that require a trigger pull for each label read.
Double Read Timeout = 0.1 Second
Double Read Timeout = 0.2 Second
Double Read Timeout = 0.3 Second
Double Read Timeout = 0.4 Second
Double Read Timeout = 0.5 Second
DEFAULT Double Read Timeout = 0.6 Second
Double Read Timeout = 0.7 Second
66
WLS9600
Page 77
ENTER/EXIT PROGRAMMING MODE
Label Gone Timeout
Double Read Timeout (continued)
Double Read Timeout = 0.8 Second
Double Read Timeout = 0.9 Second
Double Read Timeout = 1 Second
Label Gone Timeout This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a trigger pull for each label that is read. See page 252 in “References” for detailed instructions and examples for setting this feature.
Select Label Gone Timeout Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
Product Reference Guide
016 = Timeout of 160 ms
67
Page 78
LED and Beeper Indicators
ENTER/EXIT PROGRAMMING MODE
LED AND BEEPER INDICATORS Power On Alert Disables or enables the indication (from the Beeper) that the reader is receiving power.
Power On Alert = Disable (No Audible Indication)
DEFAULT Power On Alert = Four Beeps
Good Read: When to Indicate This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a barcode. . This option, which uses CTS, is only valid for RS-232 interfaces.
DEFAULT Indicate Good Read = After Decode
Indicate Good Read = After Transmit
Indicate Good Read = After CTS Goes Inactive, Then Active
68
WLS9600
Page 79
ENTER/EXIT PROGRAMMING MODE
Good Read Beep Type
Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound.
DEFAULT Good Read Beep Type = Mono
Good Read Beep Type = Bitonal
Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.)
Good Read Beep Frequency = Low
Good Read Beep Frequency = Medium
DEFAULT Good Read Beep Frequency = High
Product Reference Guide
69
Page 80
LED and Beeper Indicators
ENTER/EXIT PROGRAMMING MODE
Good Read Beep Length
Good Read Beep Length = 60 msec
DEFAULT Good Read Beep Length = 80 msec
Good Read Beep Length = 100 msec
Good Read Beep Length = 120 msec
Good Read Beep Length = 140 msec
Good Read Beep Length = 160 msec
Good Read Beep Length = 180 msec
Good Read Beep Length = 200 msec
70
WLS9600
Page 81
ENTER/EXIT PROGRAMMING MODE
Good Read Beep Volume
Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels.
Good Read Beep Volume = Beeper Off
Good Read Beep Volume = Low
Good Read Beep Volume = Medium
DEFAULT Good Read Beep Volume = High
Product Reference Guide
71
Page 82
LED and Beeper Indicators
ENTER/EXIT PROGRAMMING MODE
Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in 100ms increments. See page 253 in “References” for detailed instructions and examples for setting this feature.
Select Good Read LED Duration Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
003 = Good Read LED stays on for 300 ms
Indicators are dimmed during sleep.
72
WLS9600
Page 83
ENTER/EXIT PROGRAMMING MODE
Scan Mode
SCANNING FEATURES Scan Mode Selects the reader’s scan operating mode. See page 254 in “References” for descriptions.
DEFAULT Scan Mode = Trigger Single
Scan Mode = Trigger Hold Multiple
Scan Mode = Trigger Pulse Multiple
Scan Mode = Flashinga
Scan Mode = Always Onb a. Recommended scan mode for hands-free stand mode operation. b. See "Laser Features" starting on page 227 for additional laser programmable timeout options.
Product Reference Guide
73
Page 84
Scanning Features
ENTER/EXIT PROGRAMMING MODE
Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments. See page 255 in “References” for descriptions of each feature
Select Scanning Active Time Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
005 = Scanning is active for 5 Seconds
Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.See page 256 in “References” for detailed information on setting this feature.
Select Flash ON Time Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
74
10 = Flash is ON for 1 Second
WLS9600