Page 75

READING PARAMETERS

DOUBLE READ TIMEOUT on page 66

GOOD READ BEEP VOLUME on page 71

LABEL GONE TIMEOUT on page 67

GOOD READ LED DURATION on page 72

POWER ON ALERT on page 68

SCAN MODE on page 73

GOOD READ: WHEN TO INDICATE on page 68 SCANNING ACTIVE TIME on page 74 GOOD READ BEEP TYPE on page 69

FLASH ON TIME on page 74

GOOD READ BEEP FREQUENCY on page 69

FLASH OFF TIME on page 75

GOOD READ BEEP LENGTH on page 70

GREEN SPOT DURATION on page 75

Product Reference Guide

65

Page 76

ENTER/EXIT PROGRAMMING MODE

Double Read Timeout Double Read Timeout prevents a double read of the same label by setting the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the specified timeout, the second read is ignored. Double Read Timeout does not apply to scan modes that require a trigger pull for each label read.

Double Read Timeout = 0.1 Second

Double Read Timeout = 0.2 Second

Double Read Timeout = 0.3 Second

Double Read Timeout = 0.4 Second

Double Read Timeout = 0.5 Second

DEFAULT Double Read Timeout = 0.6 Second

Double Read Timeout = 0.7 Second

66

WLS9600

Page 77

ENTER/EXIT PROGRAMMING MODE

Label Gone Timeout

Double Read Timeout (continued)

Double Read Timeout = 0.8 Second

Double Read Timeout = 0.9 Second

Double Read Timeout = 1 Second

Label Gone Timeout This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a trigger pull for each label that is read. See page 252 in “References” for detailed instructions and examples for setting this feature.

Select Label Gone Timeout Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

Product Reference Guide

016 = Timeout of 160 ms

67

Page 78

LED and Beeper Indicators

ENTER/EXIT PROGRAMMING MODE

LED AND BEEPER INDICATORS Power On Alert Disables or enables the indication (from the Beeper) that the reader is receiving power.

Power On Alert = Disable (No Audible Indication)

DEFAULT Power On Alert = Four Beeps

Good Read: When to Indicate This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a barcode. . This option, which uses CTS, is only valid for RS-232 interfaces.

DEFAULT Indicate Good Read = After Decode

Indicate Good Read = After Transmit

Indicate Good Read = After CTS Goes Inactive, Then Active

68

WLS9600

Page 79

ENTER/EXIT PROGRAMMING MODE

Good Read Beep Type

Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound.

DEFAULT Good Read Beep Type = Mono

Good Read Beep Type = Bitonal

Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.)

Good Read Beep Frequency = Low

Good Read Beep Frequency = Medium

DEFAULT Good Read Beep Frequency = High

Product Reference Guide

69

Page 80

LED and Beeper Indicators

ENTER/EXIT PROGRAMMING MODE

Good Read Beep Length

Good Read Beep Length = 60 msec

DEFAULT Good Read Beep Length = 80 msec

Good Read Beep Length = 100 msec

Good Read Beep Length = 120 msec

Good Read Beep Length = 140 msec

Good Read Beep Length = 160 msec

Good Read Beep Length = 180 msec

Good Read Beep Length = 200 msec

70

WLS9600

Page 81

ENTER/EXIT PROGRAMMING MODE

Good Read Beep Volume

Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels.

Good Read Beep Volume = Beeper Off

Good Read Beep Volume = Low

Good Read Beep Volume = Medium

DEFAULT Good Read Beep Volume = High

Product Reference Guide

71

Page 82

LED and Beeper Indicators

ENTER/EXIT PROGRAMMING MODE

Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in 100ms increments. See page 253 in “References” for detailed instructions and examples for setting this feature.

Select Good Read LED Duration Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

003 = Good Read LED stays on for 300 ms

Indicators are dimmed during sleep.

72

WLS9600

Page 83

ENTER/EXIT PROGRAMMING MODE

Scan Mode

SCANNING FEATURES Scan Mode Selects the reader’s scan operating mode. See page 254 in “References” for descriptions.

DEFAULT Scan Mode = Trigger Single

Scan Mode = Trigger Hold Multiple

Scan Mode = Trigger Pulse Multiple

Scan Mode = Flashinga

Scan Mode = Always Onb a. Recommended scan mode for hands-free stand mode operation. b. See "Laser Features" starting on page 227 for additional laser programmable timeout options.

Product Reference Guide

73

Page 84

Scanning Features

ENTER/EXIT PROGRAMMING MODE

Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments. See page 255 in “References” for descriptions of each feature

Select Scanning Active Time Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

005 = Scanning is active for 5 Seconds

Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.See page 256 in “References” for detailed information on setting this feature.

Select Flash ON Time Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

74

10 = Flash is ON for 1 Second

WLS9600