The text of a manual · part 12 of 35
WLS9600 1D Laser Scanner Product Reference Guide: Configuration Using Barcodes, pages 85 to 94
Pages 85 to 94 of 306, from WLS9600 1D Laser Scanner Product Reference Guide
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wasp WLS-9600
Page 85
ENTER/EXIT PROGRAMMING MODE
Flash Off Time
Flash Off Time This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. See page 257 in “References” for detailed information on setting this feature.
Select Flash OFF Time Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
06 = Flash is OFF for 600ms
Green Spot Duration Specifies the duration of the good read pointer beam after a good read.
Green Spot Duration = Disable (Green Spot is Off)
DEFAULT Green Spot Duration = Short (300 msec)
Green Spot Duration = Medium (500 msec)
Green Spot Duration = Long (800 msec)
Product Reference Guide
75
Page 86
Scanning Features
ENTER/EXIT PROGRAMMING MODE
NOTES
76
WLS9600
Page 87
CODE SELECTION The reader supports the following symbologies (barcode types). Symbology-dependent options for each symbology are included in this chapter.
CODE EAN/UPC on page 79 • Coupon Control • UPC-A • UPC-E • EAN 13 (Jan 13) • ISSN • EAN 8 (Jan 8) • UPC/EAN Global Settings
STANDARD 2 OF 5 on page 148 INDUSTRIAL 2 OF 5 on page 154 • Code IATA
CHINA POSTAL CODE on page 161 CODABAR on page 167 • ABC Codabar
CODE 11 on page 182 GS1 DATABAR™ OMNIDIRECTIONAL on page 191
CODE 39 on page 106
• GS1 DataBar™ Omnidirectional
• Code 32 (ITAL Pharmaceutical Code)
• GS1 DataBar™ Expanded
• Code 39 CIP (French Pharmaceutical)
• GS1 DataBar™ Limited
CODE 128 on page 121 • GS1-128
CODE ISBT 128 on page 132 CODABLOCK F on page 135 INTERLEAVED 2 OF 5 (I 2 OF 5) on page 139
CODE 93 on page 199 MSI on page 207 PLESSEY on page 213 CODE 4 on page 221 CODE 5 on page 222
• Follett 2 of 5 • Interleaved 2 of 5 CIP HR Default settings are indicated at each feature/option with a green arrow. Also reference Appendix B, Standard Defaults for a listing of the most widely used set of standard factory settings. That section also provides space to record any custom settings needed or implemented for your system. To set most features: 1. Scan the ENTER/EXIT PROGRAMMING barcode at the top of applicable programming pages. 2. Scan the correct barcode to set the desired programming feature or parameter. You may need to cover unused barcodes on the page, and possibly the facing page, to ensure that the reader reads only the barcode you intend to scan.
Product Reference Guide
77
Page 88
Disable All Symbologies 3. If additional input parameters are needed, go to Appendix D, Keypad, and scan the appropriate characters from the keypad. Additional information about many features can be found in the “References” chapter. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
4. Complete the programming sequence by scanning the ENTER/EXIT PROGRAMMING barcode to exit Programming Mode.
DISABLE ALL SYMBOLOGIES Use this feature to disable all symbologies. 1. Scan the ENTER/EXIT PROGRAMMING barcode below. 2. Scan the Disable All Symbologies barcode. 3. Complete the programming sequence by scanning the ENTER/EXIT PROGRAMMING barcode.
ENTER/EXIT PROGRAMMING MODE
Disable All Symbologies
This does not disable the reading of programming labels.
78
WLS9600
Page 89
ENTER/EXIT PROGRAMMING MODE
Coupon Control
CODE EAN/UPC Coupon Control This feature is used to control the reader’s method of processing coupon labels.
Coupon Control = Allow all coupon barcodes to be decoded
DEFAULT Coupon Control = Enable only UPCA coupon decoding
Coupon Control = Enable only GS1 DataBar™ coupon decoding
Product Reference Guide
79
Page 90
Code EAN/UPC
ENTER/EXIT PROGRAMMING MODE
UPC-A The following options apply to the UPC-A symbology.
UPC-A Enable/Disable When disabled, the reader will not read UPC-A barcodes.
UPC-A = Disable
DEFAULT UPC-A = Enable
UPC-A Check Character Transmission Enable this option to transmit the check character along with UPC-A barcode data.
UPC-A Check Character Transmission = Don’t Send
DEFAULT UPC-A Check Character Transmission = Send
80
WLS9600
Page 91
ENTER/EXIT PROGRAMMING MODE
Expand UPC-A to EAN-13
Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.
DEFAULT UPC-A to EAN-13 = Don’t Expand
UPC-A to EAN-13 = Expand
UPC-A Number System Character Transmission This feature enables/disables transmission of the UPC-A number system character.
UPC-A Number System Character = Do not transmit
DEFAULT UPC-A Number System Character = Transmit
Product Reference Guide
81
Page 92
Code EAN/UPC
ENTER/EXIT PROGRAMMING MODE
UPC-A Minimum Reads This feature specifies the minimum number of consecutive times a UPC-A label must be decoded before it is accepted as a good read.
DEFAULT UPC-A Minimum Reads = 1
UPC-A Minimum Reads = 2
UPC-A Minimum Reads = 3
UPC-A Minimum Reads = 4
82
WLS9600
Page 93
ENTER/EXIT PROGRAMMING MODE
UPC-E Enable/Disable
UPC-E The following options apply to the UPC-E symbology.
UPC-E Enable/Disable When disabled, the reader will not read UPC-E barcodes.
UPC-E = Disable
DEFAULT UPC-E = Enable
UPC-E Check Character Transmission Enable this option to transmit the check character along with UPC-E barcode data.
UPC-E Check Character Transmission = Don’t Send
DEFAULT UPC-E Check Character Transmission = Send
Product Reference Guide
83
Page 94
UPC-E
ENTER/EXIT PROGRAMMING MODE
Expand UPC-E to EAN-13 Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.
DEFAULT UPC-E to EAN-13 = Don’t Expand
UPC-E to EAN-13 = Expand
Expand UPC-E to UPC-A Expands UPC-E data to the UPC-A data format.
DEFAULT UPC-E to UPC-A = Don’t Expand
UPC-E to UPC-A = Expand
84
WLS9600