Page 85

ENTER/EXIT PROGRAMMING MODE

Flash Off Time

Flash Off Time This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. See page 257 in “References” for detailed information on setting this feature.

Select Flash OFF Time Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

06 = Flash is OFF for 600ms

Green Spot Duration Specifies the duration of the good read pointer beam after a good read.

Green Spot Duration = Disable (Green Spot is Off)

DEFAULT Green Spot Duration = Short (300 msec)

Green Spot Duration = Medium (500 msec)

Green Spot Duration = Long (800 msec)

Product Reference Guide

75

Page 86

Scanning Features

ENTER/EXIT PROGRAMMING MODE

NOTES

76

WLS9600

Page 87

CODE SELECTION The reader supports the following symbologies (barcode types). Symbology-dependent options for each symbology are included in this chapter.

CODE EAN/UPC on page 79 • Coupon Control • UPC-A • UPC-E • EAN 13 (Jan 13) • ISSN • EAN 8 (Jan 8) • UPC/EAN Global Settings

STANDARD 2 OF 5 on page 148 INDUSTRIAL 2 OF 5 on page 154 • Code IATA

CHINA POSTAL CODE on page 161 CODABAR on page 167 • ABC Codabar

CODE 11 on page 182 GS1 DATABAR™ OMNIDIRECTIONAL on page 191

CODE 39 on page 106

• GS1 DataBar™ Omnidirectional

• Code 32 (ITAL Pharmaceutical Code)

• GS1 DataBar™ Expanded

• Code 39 CIP (French Pharmaceutical)

• GS1 DataBar™ Limited

CODE 128 on page 121 • GS1-128

CODE ISBT 128 on page 132 CODABLOCK F on page 135 INTERLEAVED 2 OF 5 (I 2 OF 5) on page 139

CODE 93 on page 199 MSI on page 207 PLESSEY on page 213 CODE 4 on page 221 CODE 5 on page 222

• Follett 2 of 5 • Interleaved 2 of 5 CIP HR Default settings are indicated at each feature/option with a green arrow. Also reference Appendix B, Standard Defaults for a listing of the most widely used set of standard factory settings. That section also provides space to record any custom settings needed or implemented for your system. To set most features: 1. Scan the ENTER/EXIT PROGRAMMING barcode at the top of applicable programming pages. 2. Scan the correct barcode to set the desired programming feature or parameter. You may need to cover unused barcodes on the page, and possibly the facing page, to ensure that the reader reads only the barcode you intend to scan.

Product Reference Guide

77

Page 88

Disable All Symbologies 3. If additional input parameters are needed, go to Appendix D, Keypad, and scan the appropriate characters from the keypad. Additional information about many features can be found in the “References” chapter. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

4. Complete the programming sequence by scanning the ENTER/EXIT PROGRAMMING barcode to exit Programming Mode.

DISABLE ALL SYMBOLOGIES Use this feature to disable all symbologies. 1. Scan the ENTER/EXIT PROGRAMMING barcode below. 2. Scan the Disable All Symbologies barcode. 3. Complete the programming sequence by scanning the ENTER/EXIT PROGRAMMING barcode.

ENTER/EXIT PROGRAMMING MODE

Disable All Symbologies

This does not disable the reading of programming labels.

78

WLS9600

Page 89

ENTER/EXIT PROGRAMMING MODE

Coupon Control

CODE EAN/UPC Coupon Control This feature is used to control the reader’s method of processing coupon labels.

Coupon Control = Allow all coupon barcodes to be decoded

DEFAULT Coupon Control = Enable only UPCA coupon decoding

Coupon Control = Enable only GS1 DataBar™ coupon decoding

Product Reference Guide

79

Page 90

Code EAN/UPC

ENTER/EXIT PROGRAMMING MODE

UPC-A The following options apply to the UPC-A symbology.

UPC-A Enable/Disable When disabled, the reader will not read UPC-A barcodes.

UPC-A = Disable

DEFAULT UPC-A = Enable

UPC-A Check Character Transmission Enable this option to transmit the check character along with UPC-A barcode data.

UPC-A Check Character Transmission = Don’t Send

DEFAULT UPC-A Check Character Transmission = Send

80

WLS9600

Page 91

ENTER/EXIT PROGRAMMING MODE

Expand UPC-A to EAN-13

Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.

DEFAULT UPC-A to EAN-13 = Don’t Expand

UPC-A to EAN-13 = Expand

UPC-A Number System Character Transmission This feature enables/disables transmission of the UPC-A number system character.

UPC-A Number System Character = Do not transmit

DEFAULT UPC-A Number System Character = Transmit

Product Reference Guide

81

Page 92

Code EAN/UPC

ENTER/EXIT PROGRAMMING MODE

UPC-A Minimum Reads This feature specifies the minimum number of consecutive times a UPC-A label must be decoded before it is accepted as a good read.

DEFAULT UPC-A Minimum Reads = 1

UPC-A Minimum Reads = 2

UPC-A Minimum Reads = 3

UPC-A Minimum Reads = 4

82

WLS9600

Page 93

ENTER/EXIT PROGRAMMING MODE

UPC-E Enable/Disable

UPC-E The following options apply to the UPC-E symbology.

UPC-E Enable/Disable When disabled, the reader will not read UPC-E barcodes.

UPC-E = Disable

DEFAULT UPC-E = Enable

UPC-E Check Character Transmission Enable this option to transmit the check character along with UPC-E barcode data.

UPC-E Check Character Transmission = Don’t Send

DEFAULT UPC-E Check Character Transmission = Send

Product Reference Guide

83

Page 94

UPC-E

ENTER/EXIT PROGRAMMING MODE

Expand UPC-E to EAN-13 Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.

DEFAULT UPC-E to EAN-13 = Don’t Expand

UPC-E to EAN-13 = Expand

Expand UPC-E to UPC-A Expands UPC-E data to the UPC-A data format.

DEFAULT UPC-E to UPC-A = Don’t Expand

UPC-E to UPC-A = Expand