Page 35

ENTER/EXIT PROGRAMMING MODE

Intercharacter Delay

Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. See page 232 for more information.

Intercharacter Delay = No Delay

Select Intercharacter Delay Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

00 = No Intercharacter Delay

Beep On ASCII BEL When this parameter is enabled, the reader issues a beep when a <BEL> character is detected on the RS-232 serial line. <BEL> is issued to gain a user's attention to an illegal entry or other important event.

DEFAULT Beep On ASCII BEL = Disable

Beep On ASCII BEL = Enable

Product Reference Guide

25

Page 36

ENTER/EXIT PROGRAMMING MODE

Beep On Not on File This option enables/disables the action of the reader to sound a three beep sequence upon receiving a Not-On-File (NOF) host command.

Beep On Not On File = Disable

DEFAULT Beep On Not On File = Enable

26

WLS9600

Page 37

ENTER/EXIT PROGRAMMING MODE

ACK NAK Options

ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. See page 233 for more information.

DEFAULT ACK/NAK Protocol = Disable ACK/NAK

ACK/NAK Protocol = Enable for label transmission

ACK/NAK Protocol = Enable for host-command acknowledge

ACK/NAK Protocol = Enable for label transmission and hostcommand acknowledge

Product Reference Guide

27

Page 38

ENTER/EXIT PROGRAMMING MODE

ACK Character This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See page 233 for more information. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits.

Select ACK Character Setting

DEFAULT

0x06 ‘ACK’ Character

NAK Character This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See page 234 for more information. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits.

Select NAK Character Setting

DEFAULT

28

0x15 ‘NAK’ Character

WLS9600

Page 39

ENTER/EXIT PROGRAMMING MODE

ACK NAK Timeout Value

ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout. See page 235 for more information on setting this feature.

Select ACK NAK Timeout Value Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

01 ACK NAK Timeout value is 200ms

ACK NAK Retry Count This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries. See page 236 for more information.

Select ACK NAK Retry Count Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

Product Reference Guide

003 = 3 Retries

29

Page 40

ENTER/EXIT PROGRAMMING MODE

ACK NAK Error Handling This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host.

DEFAULT ACK NAK Error Handling = Ignore Errors Detected

ACK NAK Error Handling = Process Error as Valid ACK Character

ACK NAK Error Handling = Process Error as Valid NAK Character

Indicate Transmission Failure This option enables/disables the reader’s ability to sound an error beep to indicate a transmission failure while in ACK/NAK mode.

Indicate Transmission Failure = Disable Indication

DEFAULT Indicate Transmission Failure = Enable Indication

30

WLS9600

Page 41

ENTER/EXIT PROGRAMMING MODE

Disable Character

Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8bit data is not recognized when the option Data Bits has been set as 7 Data Bits.

See page 237 for more information on setting this feature.

Select Disable Character Setting

DEFAULT

0x44 = Disable Character is ‘D’

Enable Character Specifies the value of the RS-232 host command used to enable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8bit data is not recognized when the option Data Bits has been set as 7 Data Bits.

See page 238 in “References” for more information on setting this feature.

Select Enable Character Setting

DEFAULT

Product Reference Guide

0x45 = Enable Character is ‘E’

31

Page 42

ENTER/EXIT PROGRAMMING MODE

NOTES

32

WLS9600

Page 43

KEYBOARD INTERFACE

COUNTRY MODE on page 34 CAPS LOCK STATE on page 37 NUMLOCK on page 38 SEND CONTROL CHARACTERS on page 39 WEDGE QUIET INTERVAL on page 40 INTERCHARACTER DELAY on page 41 INTERCODE DELAY on page 42 USB KEYBOARD SPEED on page 43 USB KEYBOARD NUMERIC KEYPAD on page 44

Use the programming barcodes in this chapter to select options for USB Keyboard and Wedge Interfaces. Reference Appendix B, Standard Defaults for a listing of standard factory settings. Information about control character emulation which applies to keyboard interfaces is listed in Appendix E, Scancode Tables.

Product Reference Guide

33

Page 44

ENTER/EXIT PROGRAMMING MODE

Country Mode This feature specifies the country/language supported by the keyboard. Only the following interfaces support ALL Country Modes. • USB Keyboard (without alternate key encoding) • AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Std Key Encoding • Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard • AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 without Alternate Key • Keyboard Wedge for IBM AT PS2 without alternate key encoding but without external keyboard • Bluetooth HID Profile All other interfaces support ONLY the following Country Modes: U.S., Belgium, Britain, France, Germany, Italy, Spain, Sweden.

DEFAULT Country Mode = U.S.

Country Mode = Belgium

Country Mode = Britain

Supports only the interfaces listed in the Country Mode feature description. Country Mode = Croatia

Supports only the interfaces listed in the Country Mode feature description. Country Mode = Czech Republic

34

WLS9600