The text of a manual · part 7 of 35
WLS9600 1D Laser Scanner Product Reference Guide: Configuration Using Barcodes, pages 35 to 44
Pages 35 to 44 of 306, from WLS9600 1D Laser Scanner Product Reference Guide
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wasp WLS-9600
Page 35
ENTER/EXIT PROGRAMMING MODE
Intercharacter Delay
Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. See page 232 for more information.
Intercharacter Delay = No Delay
Select Intercharacter Delay Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
00 = No Intercharacter Delay
Beep On ASCII BEL When this parameter is enabled, the reader issues a beep when a <BEL> character is detected on the RS-232 serial line. <BEL> is issued to gain a user's attention to an illegal entry or other important event.
DEFAULT Beep On ASCII BEL = Disable
Beep On ASCII BEL = Enable
Product Reference Guide
25
Page 36
ENTER/EXIT PROGRAMMING MODE
Beep On Not on File This option enables/disables the action of the reader to sound a three beep sequence upon receiving a Not-On-File (NOF) host command.
Beep On Not On File = Disable
DEFAULT Beep On Not On File = Enable
26
WLS9600
Page 37
ENTER/EXIT PROGRAMMING MODE
ACK NAK Options
ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. See page 233 for more information.
DEFAULT ACK/NAK Protocol = Disable ACK/NAK
ACK/NAK Protocol = Enable for label transmission
ACK/NAK Protocol = Enable for host-command acknowledge
ACK/NAK Protocol = Enable for label transmission and hostcommand acknowledge
Product Reference Guide
27
Page 38
ENTER/EXIT PROGRAMMING MODE
ACK Character This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See page 233 for more information. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits.
Select ACK Character Setting
DEFAULT
0x06 ‘ACK’ Character
NAK Character This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See page 234 for more information. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits.
Select NAK Character Setting
DEFAULT
28
0x15 ‘NAK’ Character
WLS9600
Page 39
ENTER/EXIT PROGRAMMING MODE
ACK NAK Timeout Value
ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout. See page 235 for more information on setting this feature.
Select ACK NAK Timeout Value Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
01 ACK NAK Timeout value is 200ms
ACK NAK Retry Count This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries. See page 236 for more information.
Select ACK NAK Retry Count Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
Product Reference Guide
003 = 3 Retries
29
Page 40
ENTER/EXIT PROGRAMMING MODE
ACK NAK Error Handling This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host.
DEFAULT ACK NAK Error Handling = Ignore Errors Detected
ACK NAK Error Handling = Process Error as Valid ACK Character
ACK NAK Error Handling = Process Error as Valid NAK Character
Indicate Transmission Failure This option enables/disables the reader’s ability to sound an error beep to indicate a transmission failure while in ACK/NAK mode.
Indicate Transmission Failure = Disable Indication
DEFAULT Indicate Transmission Failure = Enable Indication
30
WLS9600
Page 41
ENTER/EXIT PROGRAMMING MODE
Disable Character
Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8bit data is not recognized when the option Data Bits has been set as 7 Data Bits.
See page 237 for more information on setting this feature.
Select Disable Character Setting
DEFAULT
0x44 = Disable Character is ‘D’
Enable Character Specifies the value of the RS-232 host command used to enable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8bit data is not recognized when the option Data Bits has been set as 7 Data Bits.
See page 238 in “References” for more information on setting this feature.
Select Enable Character Setting
DEFAULT
Product Reference Guide
0x45 = Enable Character is ‘E’
31
Page 42
ENTER/EXIT PROGRAMMING MODE
NOTES
32
WLS9600
Page 43
KEYBOARD INTERFACE
COUNTRY MODE on page 34 CAPS LOCK STATE on page 37 NUMLOCK on page 38 SEND CONTROL CHARACTERS on page 39 WEDGE QUIET INTERVAL on page 40 INTERCHARACTER DELAY on page 41 INTERCODE DELAY on page 42 USB KEYBOARD SPEED on page 43 USB KEYBOARD NUMERIC KEYPAD on page 44
Use the programming barcodes in this chapter to select options for USB Keyboard and Wedge Interfaces. Reference Appendix B, Standard Defaults for a listing of standard factory settings. Information about control character emulation which applies to keyboard interfaces is listed in Appendix E, Scancode Tables.
Product Reference Guide
33
Page 44
ENTER/EXIT PROGRAMMING MODE
Country Mode This feature specifies the country/language supported by the keyboard. Only the following interfaces support ALL Country Modes. • USB Keyboard (without alternate key encoding) • AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Std Key Encoding • Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard • AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 without Alternate Key • Keyboard Wedge for IBM AT PS2 without alternate key encoding but without external keyboard • Bluetooth HID Profile All other interfaces support ONLY the following Country Modes: U.S., Belgium, Britain, France, Germany, Italy, Spain, Sweden.
DEFAULT Country Mode = U.S.
Country Mode = Belgium
Country Mode = Britain
Supports only the interfaces listed in the Country Mode feature description. Country Mode = Croatia
Supports only the interfaces listed in the Country Mode feature description. Country Mode = Czech Republic
34