For the Wasp WLS-9600
Page 215
ENTER/EXIT PROGRAMMING MODE
Code 93 Quiet Zones
Code 93 Quiet Zones Enables/disables quiet zones for Code 93.
Code 93 Quiet Zones = No Quiet Zones
Code 93 Quiet Zones = Quiet Zone on one side
Code 93 Quiet Zones = Quiet Zones on two sides
DEFAULT Code 93 Quiet Zones = Auto
Code 93 Quiet Zones = Virtual Quiet Zones on two sides
Product Reference Guide
205
Page 216
Code 93
ENTER/EXIT PROGRAMMING MODE
Code 93 Stitching Disable/enable fixed or variable length stitching for Code 93.
Code 93 Stitching = Disable
DEFAULT Code 93 Stitching = Enable
Code 93 Character Correlation Enables/disables Character Correlation for Code 93.
DEFAULT Code 93 Character Correlation = Disable
Code 93 Character Correlation = Enable
206
WLS9600
Page 217
ENTER/EXIT PROGRAMMING MODE
MSI Enable/Disable
MSI The following options apply to the MSI symbology.
MSI Enable/Disable Enables/Disables ability of reader to decode MSI labels.
DEFAULT MSI = Disable
MSI = Enable
MSI Check Character Calculation Enables/Disables calculation and verification of an optional MSI check character.
MSI Check Character Calculation = Disable
DEFAULT MSI Check Character Calculation = Enable Mod10
MSI Check Character Calculation = Enable Mod11/10
MSI Check Character Calculation = Enable Mod10/10
Product Reference Guide
207
Page 218
MSI
ENTER/EXIT PROGRAMMING MODE
MSI Check Character Transmission Enables/disables transmission of an MSI check character.
MSI Check Character Transmission = Disable
DEFAULT MSI Check Character Transmission = Enable
MSI Length Control This feature specifies either variable length decoding or fixed length decoding for the MSI symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set.
DEFAULT MSI Length Control = Variable Length
MSI = Fixed Length
208
WLS9600
Page 219
ENTER/EXIT PROGRAMMING MODE
MSI Set Length 1
MSI Set Length 1 This feature specifies one of the barcode lengths for MSI Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters. Table 24 provides some examples for setting Length 1. See page 242 for detailed instructions on setting this feature. Table 24. MSI Length 1 Setting Examples STEP
ACTION
1
Desired Setting
EXAMPLES 01 Characters
07 Characters
15 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT MSI LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
5
‘0’ and ‘1’
‘0’ and ‘7’
‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
Select MSI Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
Product Reference Guide
01 = Length 1 is 1 Character
209
Page 220
MSI
ENTER/EXIT PROGRAMMING MODE
MSI Set Length 2 This feature specifies one of the barcode lengths for MSI Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 25 provides examples for setting Length 2. See page 243 for detailed instructions on setting this feature. Table 25. MSI Length 2 Setting Examples STEP
ACTION
1
Desired Setting
EXAMPLES 00 (Ignore This Length)
07 Characters
15 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT MSI LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
5
‘0’ and ‘0’
‘0’ and ‘7’
‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
Select MSI Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
210
50 = Length 2 is 50 Characters
WLS9600
Page 221
ENTER/EXIT PROGRAMMING MODE
MSI Minimum Reads
MSI Minimum Reads This feature specifies the minimum number of consecutive times an MSI label must be decoded before it is accepted as good read.
MSI Minimum Reads = 1
MSI Minimum Reads = 2
MSI Minimum Reads = 3
DEFAULT MSI Minimum Reads = 4
Product Reference Guide
211
Page 222
MSI
ENTER/EXIT PROGRAMMING MODE
MSI Decoding Level Specifies the decoding level for MSI. Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 242 for more information on this feature.
MSI Decoding Level = Disable
MSI Decoding Level = 1 (conservative)
MSI Decoding Level = 2
DEFAULT MSI Decoding Level = 3
MSI Decoding Level = 4
MSI Decoding Level = 5 (aggressive)
212
WLS9600
Page 223
ENTER/EXIT PROGRAMMING MODE
Plessey Enable/Disable
PLESSEY The following options apply to the Plessey symbology.
Plessey Enable/Disable Enables/Disables ability of reader to decode Plessey labels.
DEFAULT Plessey = Disable
Plessey = Enable
Product Reference Guide
213
Page 224
Plessey
ENTER/EXIT PROGRAMMING MODE
Plessey Check Character Calculation Enables/Disables calculation and verification of an optional Plessey check character.
Plessey Check Character Calculation = Disable
DEFAULT Plessey Check Character Calculation = Enable Plessey std. check char. verification
Plessey Check Character Calculation = Enable Anker check char. verification
Plessey Check Character Calculation = Enable Plessey std. and Anker check char verification
Plessey Check Character Transmission Enables/disables transmission of an MSI check character.
Plessey Check Character Transmission = Disable
DEFAULT Plessey Check Character Transmission = Enable
214
WLS9600