Page 205
ENTER/EXIT PROGRAMMING MODE
GS1 DataBar™ Expanded Set Length 1
GS1 DataBar™ Expanded Set Length 1 This feature specifies one of the barcode lengths for GS1 DataBar™ Expanded Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 74 characters. Table 20 provides some examples for setting Length 1. See page 242 for detailed instructions on setting this feature. Table 20. GS1 DataBar™ Expanded Length 1 Setting Examples STEP
ACTION
EXAMPLES
1
Desired Setting
01 Character
07 Characters
52 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT GS1 DataBar™ EXPANDED LENGTH 1SETTING
4
Scan Two Characters From Appendix D, Keypad
5
‘0’ and ‘1’
‘0’ and ‘7’
‘5’ and ‘2’
74 Characters
‘7’ AND ‘4’
Scan ENTER/EXIT PROGRAMMING MODE
Select GS1 DataBar™ Expanded Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
Product Reference Guide
01 = Length 1 is 1 Character
195
Page 206
GS1 DataBar™ Expanded
ENTER/EXIT PROGRAMMING MODE
GS1 DataBar™ Expanded Set Length 2 This feature specifies one of the barcode lengths for GS1 DataBar™ Expanded Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 74 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 21 provides examples for setting Length 2. See page 243 for detailed instructions on setting this feature. Table 21. GS1 DataBar™ Expanded Length 2 Setting Examples STEP
ACTION
EXAMPLES
1
Desired Setting
00 (ignore second length)
07 Characters
52 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT GS1 DataBar™ EXPANDED LENGTH 2 SETTING
4 5
Scan Two Characters From Appendix D, Keypad
‘0’ and ‘0’
‘0’ and ‘7’
‘5’ and ‘2’
74 Characters
‘7’ and ‘4’
Scan ENTER/EXIT PROGRAMMING MODE
Select GS1 DataBar™ Expanded Set Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
196
74 = Length 2 is 74 Characters
WLS9600
Page 207
ENTER/EXIT PROGRAMMING MODE
GS1 DataBar™ Limited Enable/Disable
GS1 DATABAR™ LIMITED The following options apply to the GS1 DataBar™ Limited (formerly RSS Limited) symbology.
GS1 DataBar™ Limited Enable/Disable When disabled, the reader will not read GS1 DataBar™ Limited barcodes.
DEFAULT GS1 DataBar™ Limited = Disable
GS1 DataBar™ Limited = Enable
GS1 DataBar™ Limited GS1-128 Emulation When enabled, GS1 DataBar™ Limited barcodes will be translated to the GS1-128 label data format.
DEFAULT GS1 DataBar™ Limited GS1-128 Emulation = Disable
GS1 DataBar™ Limited GS1-128 Emulation = Enable
Product Reference Guide
197
Page 208
GS1 DataBar™ Limited
ENTER/EXIT PROGRAMMING MODE
GS1 DataBar™ Limited Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar™ Limited label must be decoded before it is accepted as good read.
DEFAULT GS1 DataBar™ Limited Minimum Reads = 1
GS1 DataBar™ Limited Minimum Reads = 2
GS1 DataBar™ Limited Minimum Reads = 3
GS1 DataBar™ Limited Minimum Reads = 4
198
WLS9600
Page 209
ENTER/EXIT PROGRAMMING MODE
Code 93 Enable/Disable
CODE 93 The following options apply to the Code 93 symbology.
Code 93 Enable/Disable Enables/Disables ability of reader to decode Code 93 labels.
DEFAULT Code 93 = Disable
Code 93 = Enable
Code 93 Check Character Calculation Enables/disables calculation and verification of an optional Code 93 check character.
Code 93 Check Character Calculation = Disable
Code 93 Check Character Calculation = Enable Check C
Code 93 Check Character Calculation = Enable Check K
DEFAULT Code 93 Check Character Calculation = Enable Check C and K
Product Reference Guide
199
Page 210
Code 93
ENTER/EXIT PROGRAMMING MODE
Code 93 Check Character Transmission Enables/disables transmission of an optional Code 93 check character.
DEFAULT Code 93 Check Character Transmission = Disable
Code 93 Check Character Transmission = Enable
Code 93 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set.
DEFAULT Code 93 Length Control = Variable Length
Code 93 = Fixed Length
200
WLS9600
Page 211
ENTER/EXIT PROGRAMMING MODE
Code 93 Set Length 1
Code 93 Set Length 1 Specifies one of the barcode lengths for Code 93 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters. Table 22 provides some examples for setting Length 1. See page 242 for detailed instructions on setting this feature. Table 22. Code 93 Length 1 Setting Examples STEP
ACTION
1
Desired Setting
EXAMPLES 01 Characters
07 Characters
15 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 93 LENGTH 1 SETTING
4
Scan Two Characters From
‘0’ and ‘1’
Appendix D, Keypad
5
‘0’ and ‘7’
‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
Select Code 93 Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
Product Reference Guide
01 = Length 1 is 1 Character
201
Page 212
Code 93
ENTER/EXIT PROGRAMMING MODE
Code 93 Set Length 2 This feature specifies one of the barcode lengths for Code 93 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 23 provides examples for setting Length 2. See page 243 for detailed instructions on setting this feature. Table 23. CODE 93 Length 2 Setting Examples STEP
ACTION
1
Desired Setting
EXAMPLES 00 (Ignore This Length)
07 Characters
15 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 93 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
5
‘0’ and ‘0’
‘0’ and ‘7’
‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
Select Code 93 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
202
50 = Length 2 is 50 Characters
WLS9600
Page 213
ENTER/EXIT PROGRAMMING MODE
Code 93 Minimum Reads
Code 93 Minimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read.
DEFAULT Code 93 Minimum Reads = 1
Code 93 Minimum Reads = 2
Code 93 Minimum Reads = 3
Code 93 Minimum Reads = 4
Product Reference Guide
203
Page 214
Code 93
ENTER/EXIT PROGRAMMING MODE
Code 93 Decoding Level Specifies the decoding level for Code 93. Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 242 for more information on this feature.
Code 93 Decoding Level = Disable
Code 93 Decoding Level = 1 (Conservative)
Code 93 Decoding Level = 2
DEFAULT Code 93 Decoding Level = 3
Code 93 Decoding Level = 4
Code 93 Decoding Level = 5 (Aggressive)
204