Page 205

ENTER/EXIT PROGRAMMING MODE

GS1 DataBar™ Expanded Set Length 1

GS1 DataBar™ Expanded Set Length 1 This feature specifies one of the barcode lengths for GS1 DataBar™ Expanded Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 74 characters. Table 20 provides some examples for setting Length 1. See page 242 for detailed instructions on setting this feature. Table 20. GS1 DataBar™ Expanded Length 1 Setting Examples STEP

ACTION

EXAMPLES

1

Desired Setting

01 Character

07 Characters

52 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT GS1 DataBar™ EXPANDED LENGTH 1SETTING

4

Scan Two Characters From Appendix D, Keypad

5

‘0’ and ‘1’

‘0’ and ‘7’

‘5’ and ‘2’

74 Characters

‘7’ AND ‘4’

Scan ENTER/EXIT PROGRAMMING MODE

Select GS1 DataBar™ Expanded Set Length 1 Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

Product Reference Guide

01 = Length 1 is 1 Character

195

Page 206

GS1 DataBar™ Expanded

ENTER/EXIT PROGRAMMING MODE

GS1 DataBar™ Expanded Set Length 2 This feature specifies one of the barcode lengths for GS1 DataBar™ Expanded Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 74 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 21 provides examples for setting Length 2. See page 243 for detailed instructions on setting this feature. Table 21. GS1 DataBar™ Expanded Length 2 Setting Examples STEP

ACTION

EXAMPLES

1

Desired Setting

00 (ignore second length)

07 Characters

52 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT GS1 DataBar™ EXPANDED LENGTH 2 SETTING

4 5

Scan Two Characters From Appendix D, Keypad

‘0’ and ‘0’

‘0’ and ‘7’

‘5’ and ‘2’

74 Characters

‘7’ and ‘4’

Scan ENTER/EXIT PROGRAMMING MODE

Select GS1 DataBar™ Expanded Set Length 2 Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

196

74 = Length 2 is 74 Characters

WLS9600

Page 207

ENTER/EXIT PROGRAMMING MODE

GS1 DataBar™ Limited Enable/Disable

GS1 DATABAR™ LIMITED The following options apply to the GS1 DataBar™ Limited (formerly RSS Limited) symbology.

GS1 DataBar™ Limited Enable/Disable When disabled, the reader will not read GS1 DataBar™ Limited barcodes.

DEFAULT GS1 DataBar™ Limited = Disable

GS1 DataBar™ Limited = Enable

GS1 DataBar™ Limited GS1-128 Emulation When enabled, GS1 DataBar™ Limited barcodes will be translated to the GS1-128 label data format.

DEFAULT GS1 DataBar™ Limited GS1-128 Emulation = Disable

GS1 DataBar™ Limited GS1-128 Emulation = Enable

Product Reference Guide

197

Page 208

GS1 DataBar™ Limited

ENTER/EXIT PROGRAMMING MODE

GS1 DataBar™ Limited Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar™ Limited label must be decoded before it is accepted as good read.

DEFAULT GS1 DataBar™ Limited Minimum Reads = 1

GS1 DataBar™ Limited Minimum Reads = 2

GS1 DataBar™ Limited Minimum Reads = 3

GS1 DataBar™ Limited Minimum Reads = 4

198

WLS9600

Page 209

ENTER/EXIT PROGRAMMING MODE

Code 93 Enable/Disable

CODE 93 The following options apply to the Code 93 symbology.

Code 93 Enable/Disable Enables/Disables ability of reader to decode Code 93 labels.

DEFAULT Code 93 = Disable

Code 93 = Enable

Code 93 Check Character Calculation Enables/disables calculation and verification of an optional Code 93 check character.

Code 93 Check Character Calculation = Disable

Code 93 Check Character Calculation = Enable Check C

Code 93 Check Character Calculation = Enable Check K

DEFAULT Code 93 Check Character Calculation = Enable Check C and K

Product Reference Guide

199

Page 210

Code 93

ENTER/EXIT PROGRAMMING MODE

Code 93 Check Character Transmission Enables/disables transmission of an optional Code 93 check character.

DEFAULT Code 93 Check Character Transmission = Disable

Code 93 Check Character Transmission = Enable

Code 93 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set.

DEFAULT Code 93 Length Control = Variable Length

Code 93 = Fixed Length

200

WLS9600

Page 211

ENTER/EXIT PROGRAMMING MODE

Code 93 Set Length 1

Code 93 Set Length 1 Specifies one of the barcode lengths for Code 93 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters. Table 22 provides some examples for setting Length 1. See page 242 for detailed instructions on setting this feature. Table 22. Code 93 Length 1 Setting Examples STEP

ACTION

1

Desired Setting

EXAMPLES 01 Characters

07 Characters

15 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT CODE 93 LENGTH 1 SETTING

4

Scan Two Characters From

‘0’ and ‘1’

Appendix D, Keypad

5

‘0’ and ‘7’

‘1’ and ‘5’

50 Characters

‘5’ AND ‘0’

Scan ENTER/EXIT PROGRAMMING MODE

Select Code 93 Set Length 1 Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

Product Reference Guide

01 = Length 1 is 1 Character

201

Page 212

Code 93

ENTER/EXIT PROGRAMMING MODE

Code 93 Set Length 2 This feature specifies one of the barcode lengths for Code 93 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 23 provides examples for setting Length 2. See page 243 for detailed instructions on setting this feature. Table 23. CODE 93 Length 2 Setting Examples STEP

ACTION

1

Desired Setting

EXAMPLES 00 (Ignore This Length)

07 Characters

15 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT CODE 93 LENGTH 2 SETTING

4

Scan Two Characters From

Appendix D, Keypad

5

‘0’ and ‘0’

‘0’ and ‘7’

‘1’ and ‘5’

50 Characters

‘5’ AND ‘0’

Scan ENTER/EXIT PROGRAMMING MODE

Select Code 93 Length 2 Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

202

50 = Length 2 is 50 Characters

WLS9600

Page 213

ENTER/EXIT PROGRAMMING MODE

Code 93 Minimum Reads

Code 93 Minimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read.

DEFAULT Code 93 Minimum Reads = 1

Code 93 Minimum Reads = 2

Code 93 Minimum Reads = 3

Code 93 Minimum Reads = 4

Product Reference Guide

203

Page 214

Code 93

ENTER/EXIT PROGRAMMING MODE

Code 93 Decoding Level Specifies the decoding level for Code 93. Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 242 for more information on this feature.

Code 93 Decoding Level = Disable

Code 93 Decoding Level = 1 (Conservative)

Code 93 Decoding Level = 2

DEFAULT Code 93 Decoding Level = 3

Code 93 Decoding Level = 4

Code 93 Decoding Level = 5 (Aggressive)

204