Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 23 of 35

WLS9600 1D Laser Scanner Product Reference Guide: Configuration Using Barcodes, pages 195 to 204

Pages 195 to 204 of 306, from WLS9600 1D Laser Scanner Product Reference Guide

The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Wasp WLS-9600

Page 195

ENTER/EXIT PROGRAMMING MODE

Code 11 Set Length 1

Code 11 Set Length 1 This feature specifies one of the barcode lengths for Code 11 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters. Table 18 provides some examples for setting Length 1. See page 242 for detailed instructions on setting this feature. Table 18. Code 11 Length 1 Setting Examples STEP

ACTION

1

Desired Setting (pad with leading zeroes)

EXAMPLES 02 Characters

07 Characters

15 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT CODE 11 LENGTH 1 SETTING

4

Scan Two Characters From Appendix D, Keypad

5

‘0’ and ‘2’

‘0’ and ‘7’

‘1’ and ‘5’

50 Characters

‘5’ AND ‘0’

Scan ENTER/EXIT PROGRAMMING MODE

Select Code 11 Set Length 1 Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

Product Reference Guide

04 = Length 1 is 4 Characters

185

Page 196

Code 11

ENTER/EXIT PROGRAMMING MODE

Code 11 Set Length 2 This feature specifies one of the barcode lengths for Code 11 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 19 provides examples for setting Length 2. See page 243 for detailed instructions on setting this feature. Table 19. Code 11 Length 2 Setting Examples STEP

ACTION

1

Desired Setting (pad with leading zeroes)

EXAMPLES 00 (Ignore This Length)

07 Characters

15 Characters

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT CODE 11 LENGTH 2 SETTING

4 5

Scan Two Characters From Appendix D, Keypad

‘0’ and ‘0’

‘0’ and ‘7’

‘0’ and ‘F’

50 Characters

‘3’ AND 2’

Scan ENTER/EXIT PROGRAMMING MODE

Select Code 11 Length 2 Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

186

50 = Length 2 is 50 Characters

WLS9600

Page 197

ENTER/EXIT PROGRAMMING MODE

Code 11 Interdigit Ratio

Code 11 Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Code 11 labels.

Code 11 Interdigit Ratio = Disable

Code 11 Interdigit Ratio = 1

Code 11 Interdigit Ratio = 2

Code11 Interdigit Ratio = 3

DEFAULT Code 11 Interdigit Ratio = 4

Code 11 Interdigit Ratio = 5

Product Reference Guide

187

Page 198

Code 11

ENTER/EXIT PROGRAMMING MODE

Code 11 Interdigit Ratio (continued)

Code 11 Interdigit Ratio = 6

Code 11 Interdigit Ratio = 7

Code 11 Interdigit Ratio = 8

Code 11 Interdigit Ratio = 9

Code 11 Interdigit Ratio = 10

188

WLS9600

Page 199

ENTER/EXIT PROGRAMMING MODE

Code 11 Decoding Level

Code 11 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 242 for more information on this feature.

Codabar Decoding Level = 1 (Conservative)

Codabar Decoding Level = 2

DEFAULT Codabar Decoding Level = 3

Codabar Decoding Level = 4

Codabar Decoding Level = 5 (Aggressive)

Product Reference Guide

189

Page 200

Code 11

ENTER/EXIT PROGRAMMING MODE

Code 11 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.

DEFAULT Code 11 Character Correlation = Disable

Code 11 Character Correlation = Enable

Code 11 Stitching This option enables/disables stitching for Code 11 labels. When parts of a Code 11 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.

DEFAULT Code 11 Stitching = Disable

Code 11 Stitching = Enable

190

WLS9600

Page 201

ENTER/EXIT PROGRAMMING MODE

GS1 DataBar™ Omnidirectional Enable/Disable

GS1 DATABAR™ OMNIDIRECTIONAL The following options apply to the GS1 DataBar™ Omnidirectional (formerly RSS-14) symbology.

GS1 DataBar™ Omnidirectional Enable/Disable When disabled, the reader will not read GS1 DataBar™ Omnidirectional barcodes.

DEFAULT GS1 DataBar™ Omnidirectional = Disable

GS1 DataBar™ Omnidirectional = Enable

GS1 DataBar™ Omnidirectional GS1-128 Emulation When enabled, GS1 DataBar™ Omnidirectional barcodes will be translated to the GS1-128 label data format.

DEFAULT GS1 DataBar™ Omnidirectional GS1-128 Emulation = Disable

GS1 DataBar™ Omnidirectional GS1-128 Emulation = Enable

Product Reference Guide

191

Page 202

GS1 DataBar™ Omnidirectional

ENTER/EXIT PROGRAMMING MODE

GS1 DataBar™ Omnidirectional Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar™ Omnidirectional label must be decoded before it is accepted as good read.

DEFAULT GS1 DataBar™ Omnidirectional Minimum Reads = 1

GS1 DataBar™ Omnidirectional Minimum Reads = 2

GS1 DataBar™ Omnidirectional Minimum Reads = 3

GS1 DataBar™ Omnidirectional Minimum Reads = 4

192

WLS9600

Page 203

ENTER/EXIT PROGRAMMING MODE

GS1 DataBar™ Expanded Enable/Disable

GS1 DATABAR™ EXPANDED The following options apply to the GS1 DataBar™ Expanded (formerly RSS Expanded) symbology.

GS1 DataBar™ Expanded Enable/Disable When disabled, the reader will not read GS1 DataBar™ Expanded barcodes.

DEFAULT GS1 DataBar™ Expanded = Disable

GS1 DataBar™ Expanded = Enable

GS1 DataBar™ Expanded GS1-128 Emulation When enabled, GS1 DataBar™ Expanded barcodes will be translated to the GS1-128 label data format.

DEFAULT GS1 DataBar™ Expanded GS1-128 Emulation = Disable

GS1 DataBar™ Expanded GS1-128 Emulation = Enable

Product Reference Guide

193

Page 204

GS1 DataBar™ Expanded

ENTER/EXIT PROGRAMMING MODE

GS1 DataBar™ Expanded Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar™ Expanded label must be decoded before it is accepted as good read.

DEFAULT GS1 DataBar™ Expanded Minimum Reads = 1

GS1 DataBar™ Expanded Minimum Reads = 2

GS1 DataBar™ Expanded Minimum Reads = 3

GS1 DataBar™ Expanded Minimum Reads = 4

GS1 DataBar™ Expanded Length Control This feature specifies either variable length decoding or fixed length decoding for the GS1 DataBar™ Expanded symbology. Variable Length. For variable-length decoding, a minimum length may be set. Fixed Length. For fixed-length decoding, two different lengths may be set.

DEFAULT GS1 DataBar™ Expanded Length Control = Variable Length

GS1 DataBar™ Expanded Length Control = Fixed Length

194

WLS9600