Page 185
ENTER/EXIT PROGRAMMING MODE
Codabar Set Length 2
Codabar Set Length 2 This feature specifies one of the barcode lengths for Codabar Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the barcode’s start, stop, check and data characters. The length must include at least one data character. The length can be set from 3 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 17 provides examples for setting Length 2. See page 243 for detailed instructions on setting this feature. Table 17. Codabar Length 2 Setting Examples STEP
ACTION
EXAMPLES
1
Desired Setting (and pad with leading zeroes)
00 Ignore This Length
07 Characters
15 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODABAR LENGTH 2 SETTING
4
Scan Two Characters From Appendix D, Keypad
5
‘0’ and ‘0’
‘0’ and ‘7’
‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
Select Codabar Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
Product Reference Guide
50 = Length 2 is 50 Characters
175
Page 186
Codabar
ENTER/EXIT PROGRAMMING MODE
Codabar Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Codabar labels.
Codabar Interdigit Ratio = Disable
Codabar Interdigit Ratio = 1
Codabar Interdigit Ratio = 2
Codabar Interdigit Ratio = 3
DEFAULT Codabar Interdigit Ratio = 4
Codabar Interdigit Ratio = 5
176
WLS9600
Page 187
ENTER/EXIT PROGRAMMING MODE
Codabar Interdigit Ratio
Codabar Interdigit Ratio (continued)
Codabar Interdigit Ratio = 6
Codabar Interdigit Ratio = 7
Codabar Interdigit Ratio = 8
Codabar Interdigit Ratio = 9
Codabar Interdigit Ratio = 10
Product Reference Guide
177
Page 188
Codabar
ENTER/EXIT PROGRAMMING MODE
Codabar Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
DEFAULT Codabar Character Correlation = Disable
Codabar Character Correlation = Enable
Codabar Stitching This option enables/disables stitching for Codabar labels. When parts of a Codabar barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
DEFAULT Codabar Stitching = Disable
Codabar Stitching = Enable
178
WLS9600
Page 189
ENTER/EXIT PROGRAMMING MODE
ABC Codabar Enable/Disable
ABC CODABAR The following options apply to the ABC Codabar symbology.
ABC Codabar Enable/Disable Enables/Disables ability of reader to decode ABC Codabar labels.
DEFAULT ABC Codabar = Disable
ABC Codabar = Enable
ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic.
DEFAULT ABC Codabar Concatenation Mode = Static
ABC Codabar Concatenation Mode = Dynamic
Product Reference Guide
179
Page 190
ABC Codabar
ENTER/EXIT PROGRAMMING MODE
ABC Codabar Dynamic Concatenation Timeout Specifies the timeout in 10-millisecond ticks used by the ABC Codabar Dynamic Concatenation Mode.
ABC Codabar Dynamic Concatenation Timeout = 50 msec
ABC Codabar Dynamic Concatenation Timeout = 100 msec
DEFAULT ABC Codabar Dynamic Concatenation Timeout = 200 msec
ABC Codabar Dynamic Concatenation Timeout = 500 msec
ABC Codabar Dynamic Concatenation Timeout = 750 msec
ABC Codabar Dynamic Concatenation Timeout = 1 Second
180
WLS9600
Page 191
ENTER/EXIT PROGRAMMING MODE
ABC Codabar Force Concatenation
ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated.
DEFAULT ABC Codabar Force Concatenation = Disable
ABC Codabar Force Concatenation = Enable
Product Reference Guide
181
Page 192
Code 11
ENTER/EXIT PROGRAMMING MODE
CODE 11 The following options apply to the Code 11 symbology.
Code 11 Enable/Disable When disabled, the reader will not read Code 11 barcodes.
DEFAULT Code 11 = Disable
Code 11 = Enable
Code 11 Check Character Calculation This option enables/disables calculation and verification of optional Code 11 check character.
Code 11 Check Character Calculation = Disable
Code 11 Check Character Calculation = Check C
Code 11 Check Character Calculation = Check K
DEFAULT Code 11 Check Character Calculation = Check C and K
182
WLS9600
Page 193
ENTER/EXIT PROGRAMMING MODE
Code 11 Check Character Transmission
Code 11 Check Character Transmission This feature enables/disables transmission of an optional Code 11 check character.
Code 11 Check Character Transmission = Don’t Send
DEFAULT Code 11 Check Character Transmission = Send
Code 11 Minimum Reads This feature specifies the minimum number of consecutive times a Code 11 label must be decoded before it is accepted as good read.
Code 11 Minimum Reads = 1
DEFAULT Code 11 Minimum Reads = 2
Code 11 Minimum Reads = 3
Code 11 Minimum Reads = 4
Product Reference Guide
183
Page 194
Code 11
ENTER/EXIT PROGRAMMING MODE
Code 11 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set.
DEFAULT Code 11 Length Control = Variable Length
Code 11 Length Control = Fixed Length
184