Page 261

Data Editing

Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done. For example, if you have the character conversion configuration item set to the following: 41423132FFFFFFFF The first pair is 4142 or AB (41 hex is an ASCII capital A, 42 hex is an ASCII capital B) and the second pair is 3132 or 12 (31 hex is an ASCII 1, 32 is an ASCII 2). The other two pairs are FFFF and FFFF. With the label, AB12BA21, it would look as follows after the character conversion: BB22BB22. The A characters were converted to B characters and the 1 characters were converted to 2 characters. Nothing is done with the last two character pairs, since they are all FF. To set Character Conversion: 1. Go to page 64 and scan the ENTER/EXIT barcode. 2. Scan the “Configure Character Conversion” barcode. 3. Determine the desired string. Sixteen positions must be determined as in the above example. Next, turn to the ASCII Chart on the inside back cover of this manual and find the equivalent hex digits needed to fulfill the string. 4. Turn to Appendix D, Keypad and scan the barcodes representing the hex characters determined in the previous step. 5. Scan the ENTER/EXIT barcode to exit Programming Mode. If less than the expected string of 16 characters are selected, scan the ENTER/EXIT barcode twice to accept the selections and exit Programming Mode.

Product Reference Guide

251

Page 262

References

Reading Parameters Label Gone Timeout This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a trigger pull for each label that is read Follow these instructions to set this feature: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Go to page 67 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT LABEL GONE TIMEOUT SETTING. 5. Scan the appropriate three alpha-numeric characters from the keypad in Appendix D, Keypad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 40 for some examples of how to set this feature. Table 40. Timeout Setting Examples STEP

ACTION

EXAMPLES

1

Desired Setting

50ms

150ms

1800ms (1.8 sec.)

2550ms (2.55 sec.)

2

Divide by 10 (and pad with leading zeroes)

005

015

180

255

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT LABEL GONE TIMEOUT SETTING

5 6

252

Scan Three Characters From Appendix D, Keypad

‘0’, ‘0’ and ‘5’

‘0’, ‘1’ and ‘5’

‘1’, ‘8’ and ‘0’

‘‘2’, ‘5’ and ‘5’

Scan ENTER/EXIT PROGRAMMING MODE

WLS9600

Page 263

Reading Parameters

Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in 100ms increments. Follow these instructions to set this feature: 1. Determine the desired setting in milliseconds. A setting of 0 means that the good read LED stays on until the next time the trigger is pulled. 2. Divide the desired setting by 10 (setting is in 100ms increments). Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 000, 20 = 020, etc. 3. Go to page 72 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT GOOD READ LED DURATION SETTING. 5. Scan the appropriate three digits from the keypad in Appendix D, Keypad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 41 for some examples of how to set this feature. Table 41. Good Read LED Duration Setting Examples STEP

ACTION

EXAMPLES

1

Desired Setting

Good Read LED stays on until next trigger pull (00)

20ms

150ms

2550ms (2.55 sec.)

2

Divide by 10 (and pad with leading zeroes)

000

002

015

255

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT LABEL GONE TIMEOUT SETTING

5

Scan Three Characters From Appendix D, Keypad

6

Product Reference Guide

‘0’, ‘0’ and ‘0’

‘0’, ‘0’ and ‘2’

‘0’, ‘1’ and ‘5’

‘2’, ‘5’ and ‘5’

Scan ENTER/EXIT PROGRAMMING MODE

253

Page 264

References

Scanning Features Scan Mode This mode is associated with typical handheld reader operation. Selects the scan operating mode for the reader. The following selections are valid for all models: Trigger Single. When the trigger is pulled, scanning is activated until one of the following occurs: - Scanning Active Time has elapsed - a label has been read - the trigger is released Trigger Hold Multiple. When the trigger is pulled, scanning starts and the product scans until the trigger is released or Scanning Active Time has elapsed. Reading a label does not disable scanning. Double Read Timeout prevents undesired multiple reads of the same label while in this mode. Trigger Pulse Multiple. When the trigger is pulled, continuous scanning is activated until Scanning Active Time has elapsed or the trigger has been released and pulled again. Double Read Timeout prevents undesired multiple reads of the same label while in this mode. Flashing. The reader flashes1 on and off regardless of the trigger status. Flash rate is controlled by Flash On Time and Flash Off Time. When Flash is ON the imager reads continuously; when Flash is OFF scanning is deactivated. Flashing is the recommended scan mode for WLS9600 hands-free (stand mode) of operation

Always On. No trigger pull is required to read a barcode. Scanning is continually on. If the trigger is pulled, the reader acts as if it is in Trigger Single Mode. Double Read Timeout prevents undesired multiple reads of the same label while in this mode.

1. Controlled by Flash On Time.

254

WLS9600

Page 265

Scanning Features

Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Go to page 74 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT SCANNING ACTIVE TIME SETTING. 5. Scan the appropriate three digits from the keypad in Appendix D, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 42 for some examples of how to set this feature.

Table 42. Scanning Active Time Setting Examples STEP

ACTION

EXAMPLES

1

Desired Setting

1 Second

90 Sec. (1.5 min.)

2

Pad leading zero(es)

001

090

180 Sec. (3 min.) 255 Seconds (4.25 min.) 180

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT SCANNING ACTIVE TIME SETTING

5

Scan Three Characters From Appendix D, Keypad

6

Product Reference Guide

‘0’, ‘0’ and ‘1’

‘0’, ‘9’ and ‘0’

‘1’, ‘8’ and ‘0’

255

‘2’, ‘5’ and ‘5’

Scan ENTER/EXIT PROGRAMMING MODE

255

Page 266

References

Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Go to page 74 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT FLASH ON TIME SETTING. 5. Scan the appropriate two digits from the keypad in Appendix D, Keypad representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 43 for some examples of how to set this feature.

Table 43. Flash On Time Setting Examples STEP

ACTION

EXAMPLES

1

Desired Setting

500ms

1,000ms (1 sec.)

5200ms (5.2 sec.)

9,900ms (9.9 sec.)

2

Divide by 100 (and pad with leading zeroes to yield two digits)

05

10

52

99

‘5’ and ‘2’

‘9’ and ‘9’

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT FLASH OFF TIME SETTING

5 6

256

Scan Two Characters From Appendix D, Keypad

‘0’ and ‘5’

‘1’ and ‘0’

Scan ENTER/EXIT PROGRAMMING MODE

WLS9600

Page 267

Scanning Features

Flash Off Time This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Go to page 75 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT FLASH OFF TIME SETTING. 5. Scan the appropriate two digits from the keypad in Appendix D, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 44 for some examples of how to set this feature.

Table 44. Flash Off Time Setting Examples STEP

ACTION

EXAMPLES

1

Desired Setting

500ms

1,000ms (1 sec.)

5200ms (5.2 sec.)

9,900ms (9.9 sec.)

2

Divide by 100 (and pad with leading zeroes to yield two digits)

05

10

52

99

‘5’ and ‘2’

‘9’ and ‘9’

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT FLASH OFF TIME SETTING

5

Scan Two Characters From Appendix D, Keypad

6

Product Reference Guide

‘0’ and ‘5’

‘1’ and ‘0’

Scan ENTER/EXIT PROGRAMMING MODE

257

Page 268

References

NOTES

258

WLS9600