The text of a manual · part 5 of 35
WLS9600 1D Laser Scanner Product Reference Guide: Setup
Pages 15 to 24 of 306, from WLS9600 1D Laser Scanner Product Reference Guide
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wasp WLS-9600
Page 15
Chapter 2 Setup Unpacking Check carefully to ensure the reader and any accessories ordered are present and undamaged. If any damage occurred during shipment, contact Wasp Technical Support. Information is shown on page 2. KEEP THE PACKAGING. Should the unit ever require service, it should be returned in its original shipping container.
Setting Up the Reader Follow the steps provided in this section to connect and get your reader up and communicating with its host. 1. Begin by Installing the Interface Cable. 2. Go to Interface Selection and set the desired interface. 3. Configure Interface Settings (only if not using factory settings for that interface) 4. Go to Configuring Other Features (if modifications are needed from factory settings)
Product Reference Guide
5
Page 16
Setup
Installing the Interface Cable For Corded versions, connect the reader cable by inserting the cable into the handle as shown in Figure 1. To remove it, insert a paper clip into the release aperture, then unplug the cable. Figure 1. Connect/disconnect the cable
RS-232 Serial Connection Turn off power to the terminal/PC and connect the reader to the terminal/PC serial port via the RS-232 cable as shown in Figure 2. If the terminal will not support POT (Power Off the Terminal) to supply reader power, use the approved power supply (AC Adapter). Plug the AC Adapter barrel connector into the socket on the RS-232 cable connector and the AC Adapter plug into a standard power outlet. Figure 2. RS-232 Connection
6
WLS9600
Page 17
Installing the Interface Cable Keyboard Wedge Connection The Keyboard Wedge cable has a ‘Y’ connection from the reader. Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the terminal/PC. Reference Figure 3. Figure 3. Keyboard Wedge Interface connection
USB Connection Connect the reader to a USB port on the terminal/PC using the correct USB cable for the interface type you ordered. Reference Figure 4. Figure 4. USB connection
Other connection types are described below and illustrated in Figure 5.
Product Reference Guide
7
Page 18
Setup
M
Figure 5. Other Interface Connections
Ke
IB
W ybo ed ard ge or...
Specific cables are required for connection to different hosts. The connectors illustrated above are examples only. Actual connectors may vary from those illustrated, but the steps to connect the reader remain the same.
Interface Selection Upon completing the physical connection between the reader and its host, proceed to Table 1 starting on page 9 to select the interface type the reader is connected to (for example: RS-232, Keyboard Wedge, USB, etc.). Scan the appropriate barcode in that section to configure your system’s correct interface type. The reader will support one of the following sets of host interfaces: • • • • •
RS-232 RS-232 OPOS USB Keyboard Wedge Wand Emulation
Setting the Interface Scan the programming barcode from this section which selects the appropriate interface type matching the system the reader will be connected to. Next, proceed to the corresponding section in this manual (also listed in Table 1 starting on page 9) to configure any desired settings and features associated with that interface. Unlike some programming features and options, interface selections require that you scan only one programming barcode label. DO NOT scan an ENTER/EXIT barcode prior to scanning an interface selection barcode. Some interfaces require the scanner to start in the disabled state when powered up. If additional scanner configuration is desired while in this state, pull the trigger and hold it for five seconds. The scanner will change to a state that allows programming with barcodes.
8
WLS9600
Page 19
Interface Selection Table 1. Available Interfaces RS-232
FEATURES
RS-232 standard interface Select RS232-STD
RS-232 Wincor-Nixdorf Select RS232-WN
Set RS-232 Interface Features starting on page 19 RS-232 for use with OPOS/UPOS/JavaPOS Select RS-232 OPOS
USB Com to simulate RS-232 standard interface Select USB-COM-STDa
USB-OEM
FEATURES
USB-OEM (can be used for OPOS/UPOS/JavaPOS) Select USB-OEM
Set USB-OEM Interface Features starting on page 45 a. Download the correct USB Com driver from www.waspbarcode.com
Product Reference Guide
9
Page 20
Setup
KEYBOARD
FEATURES
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding Select KBD-AT
Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD-AT-NK
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key Select KBD-AT-ALT
Keyboard Wedge for IBM AT PS2 with alternate key encoding but without external keyboard
Set KEYBOARD WEDGE Interface Features starting on page 33
Select KBD-AT-ALT-NK
PC/XT w/Standard Key Encoding Select KBD-XT
Keyboard Wedge for IBM Terminal 3153 Select KBD-IBM-3153
10
WLS9600
Page 21
Interface Selection
KEYBOARD (continued)
FEATURES
Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboard Select KBD-IBM-M
Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make break keyboard Select KBD-IBM-MB
Keyboard Wedge for DIGITAL Terminals VT2xx, VT3xx, VT4xx Select KBD-DIG-VT
USB Keyboard with standard key encoding
Set KEYBOARD WEDGE Interface Features starting on page 33
Select USB Keyboard
USB Keyboard with alternate key encoding Select USB Alternate Keyboard
USB Keyboard for Apple computers Select USB-KBD-APPLE WAND EMULATION
FEATURES Set WAND Interface Features
Wand Emulation Select WAND
Product Reference Guide starting on page 47
11
Page 22
Setup
Customizing Configuration Settings Configure Interface Settings If after scanning the interface barcode from the previous table, your installation requires you to select options to further customize your reader, turn to the appropriate section for your interface type in "Configuration Using Barcodes" starting on page 15. • "RS-232 ONLY Interface" on page 19 • "RS-232/USB-Com Interfaces" on page 24 • "Keyboard Interface" on page 33 • "USB-OEM Interface" on page 45 • "Wand Emulation Interface" on page 47
Global Interface Features See "Global Interface Features" on page 17 for settings configurable by all interface types.
Configuring Other Features If your installation requires different programming than the standard factory default settings, the following sections of this manual allow configuration of non-interface-specific settings you might require: Reading Parameters: Reading Parameters include programming for scanning, beeper and LED indicators and other universal settings. Code Selection: Includes options concerning the barcode label types (symbologies). These settings allow you to enable/disable symbologies, set label lengths, require check digit, etc. Laser Features: Describes options and programming specific to laser models.
Software Version Transmission The software version of the device can be transmitted over the RS-232 and Keyboard interfaces by scanning the following label.
Transmit Software Version
12
WLS9600
Page 23
Customizing Configuration Settings
Resetting the Product Configuration to Defaults Restore Custom Defaults If you aren’t sure what programming options are in your imager, or you’ve changed some options and want to restore the Custom Default Configuration that may have been saved in the scanner, scan the Restore Custom Default Configuration barcode below. This will restore the custom configuration for the currently active interface. Custom defaults are based on the interface type. Configure the imager for the correct interface before scanning this label.
Restore Custom Default Configuration
Restore Factory Configuration If you want to restore the Factory Configuration for your imager, scan either the Restore USA Factory Configuration barcode or the Restore EU Factory Configuration barcode below. Both labels restore the scanner configuration to the factory settings, including the interface type. The USA label restores Label IDs to those historically used in the USA. The EU label restores Label IDs to those historically used in Europe. The Label ID sets for USA and EU are shown in the “Label ID” section on page 55 of this manual.
Restore USA Factory Configuration
Restore EU Factory Configuration
The programming items listed in the following sections show the factory default settings for each of the menu commands.
Product Reference Guide
13
Page 24
Setup
NOTES
14
WLS9600