The text of a manual · part 17 of 35
WLS9600 1D Laser Scanner Product Reference Guide: Configuration Using Barcodes, pages 135 to 144
Pages 135 to 144 of 306, from WLS9600 1D Laser Scanner Product Reference Guide
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Wasp WLS-9600
Page 135
ENTER/EXIT PROGRAMMING MODE
Code 128 Minimum Reads
Code 128 Minimum Reads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read.
DEFAULT Code 128 Minimum Reads = 1
Code 128 Minimum Reads = 2
Code 128 Minimum Reads = 3
Code 128 Minimum Reads = 4
Product Reference Guide
125
Page 136
Code 128
ENTER/EXIT PROGRAMMING MODE
Code 128 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 242 for more information on this feature.
Code 128 Decoding Level = 1 (Conservative)
Code 128 Decoding Level = 2
DEFAULT Code 128 Decoding Level = 3
Code 128 Decoding Level = 4
Code 128 Decoding Level = 5 (Aggressive)
126
WLS9600
Page 137
ENTER/EXIT PROGRAMMING MODE
Code 128 Length Control
Code 128 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 128 symbology. See page 242 for more information..
DEFAULT Code 128 Length Control = Variable Length
Code 128 Length Control = Fixed Length
Product Reference Guide
127
Page 138
Code 128
ENTER/EXIT PROGRAMMING MODE
Code 128 Set Length 1 Specifies one of the barcode lengths for Code 128 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 80 characters. Table 4 provides some examples for setting Length 1. See page 242 for detailed instructions on setting this feature. Table 4. Code 128 Length 1 Setting Examples STEP
ACTION
1
Desired Setting
EXAMPLES 01 Character
07 Characters
15 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 128 LENGTH 1 SETTING
4 5
Scan Two Characters From Appendix D, Keypad
‘0’ and ‘1’
‘0’ and ‘7’
‘1’ and ‘5’
80 Characters
‘8’ AND ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
Select Code 128 Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
128
01 = Length 1 is 1 Character
WLS9600
Page 139
ENTER/EXIT PROGRAMMING MODE
Code 128 Set Length 2
Code 128 Set Length 2 This feature specifies one of the barcode lengths for Code 128 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 80 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 5 provides examples for setting Length 2. See page 243 for detailed instructions on setting this feature. Table 5. Code 128 Length 2 Setting Examples STEP
ACTION
1
Desired Setting
EXAMPLES 00 (Ignore This Length)
07 Characters
15 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 128 LENGTH 2 SETTING
4
Scan Two Characters From Appendix D, Keypad
5
‘0’ and ‘0’
‘0’ and ‘7’
‘0’ and ‘F’
80 Characters
‘5’ AND 0’
Scan ENTER/EXIT PROGRAMMING MODE .
Select Code 128 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
Product Reference Guide
80 = Length 2 is 80 Characters
129
Page 140
Code 128
ENTER/EXIT PROGRAMMING MODE
Code 128 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
DEFAULT Code 128 Character Correlation = Disable
Code 128 Character Correlation = Enable
Code 128 Stitching This option enables/disables stitching for Code 128 labels. When parts of a Code 128 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
Code 128 Stitching = Disable
DEFAULT Code 128 Stitching = Enable
130
WLS9600
Page 141
ENTER/EXIT PROGRAMMING MODE
GS1-128 Enable
GS1-128 The following options apply to the GS1-128 symbology. (Also known as USS-128, GS1-128, GTIN-128, UCC-128, EAN-128.)
GS1-128 Enable This option enables/disables the ability of the reader to translate GS1-128 labels to the GS1-128 data format. Options are: • Transmit GS1-128 labels in Code 128 data format. • Transmit GS1-128 labels in GS1-128 data format. • Do not transmit GS1-128 labels.
GS1-128 = Transmit in Code 128 data format
DEFAULT GS1-128 = Transmit in GS1-128 data format
GS1-128 = Do not transmit GS1-128 labels
Product Reference Guide
131
Page 142
Code ISBT 128
ENTER/EXIT PROGRAMMING MODE
CODE ISBT 128 The following options apply to the ISBT 128 symbology.
ISBT 128 Concatenation Use this option to enable/disable ISBT128 concatenation of 2 labels.
DEFAULT ISBN 128 Concatenation = Disable
ISBN 128 Concatenation = Enable
ISBT 128 Force Concatenation When enabled, this feature forces concatenation for ISBT. This option is only valid when ISBT 128 Concatenation is enabled .
DEFAULT ISBT 128 Force Concatenation = Disable
ISBT 128 Force Concatenation = Enable
132
WLS9600
Page 143
ENTER/EXIT PROGRAMMING MODE
ISBT 128 Concatenation Mode
ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic. This option is only valid when ISBT 128 Concatenation is enabled (see page 132).
DEFAULT ISBT 128 Concatenation Mode = Static
ISBT 128 Concatenation Mode = Dynamic
Product Reference Guide
133
Page 144
Code ISBT 128
ENTER/EXIT PROGRAMMING MODE
ISBT 128 Dynamic Concatenation Timeout Specifies the timeout used by the ISBT 128 Dynamic Concatenation Mode.
ISBT 128 Dynamic Concatenation Timeout = 50 msec
ISBT 128 Dynamic Concatenation Timeout = 100 msec
DEFAULT ISBT 128 Dynamic Concatenation Timeout = 200 msec
ISBT 128 Dynamic Concatenation Timeout = 500 msec
ISBT 128 Dynamic Concatenation Timeout = 750 msec
ISBT 128 Dynamic Concatenation Timeout = 1 second
134
WLS9600