Page 155
ENTER/EXIT PROGRAMMING MODE
I 2 of 5 Set Length 2
I 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for I 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 9 provides examples for setting Length 2. See page 243 for detailed instructions on setting this feature. Table 9. I 2 of 5 Length 2 Setting Examples STEP
ACTION
EXAMPLES
1
Desired Setting
Ignore This Length
4 Characters
14 Characters
50 Characters
2
Pad with leading zeroes to yield two digits
00
04
14
50
‘1’ and ‘4’
‘5’ AND ‘0’
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT I 2 OF 5 LENGTH 2 SETTING
5
Scan Two Characters From Appendix D, Keypad
6
‘0’ and ‘0’
‘0’ and ‘4’
Scan ENTER/EXIT PROGRAMMING MODE
Select I 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
Product Reference Guide
50 = Length 2 is 50 Characters
145
Page 156
Interleaved 2 of 5 (I 2 of 5)
ENTER/EXIT PROGRAMMING MODE
I 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
DEFAULT I 2 of 5 Character Correlation = Disable
I 2 of 5 Character Correlation = Enable
I 2 of 5 Stitching This option enables/disables stitching for I 2 of 5 labels. When parts of a I 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
DEFAULT I 2 of 5 Stitching = Disable
I 2 of 5 Stitching = Enable
146
WLS9600
Page 157
ENTER/EXIT PROGRAMMING MODE
Follett 2 of 5 Enable/Disable
FOLLETT 2 OF 5 The following options apply to the Follett 2 of 5 symbology.
Follett 2 of 5 Enable/Disable Enables/Disables ability of imager to decode Follett 2 of 5 labels.
DEFAULT Follett 2 of 5 = Disable
Follett 2 of 5 = Enable
INTERLEAVED 2 OF 5 CIP HR The following options apply to the Interleaved 2 of 5 CIP HR symbology.
Interleaved 2 of 5 CIP HR Enable/Disable Enables/Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels.
DEFAULT Interleaved 2 of 5 CIP HR = Disable
Interleaved 2 of 5 CIP HR = Enable
Product Reference Guide
147
Page 158
Standard 2 of 5
ENTER/EXIT PROGRAMMING MODE
STANDARD 2 OF 5 The following options apply to the Standard 2 of 5 symbology.
Standard 2 of 5 Enable/Disable When disabled, the reader will not read Standard 2 of 5 barcodes.
DEFAULT Standard 2 of 5 = Disable
Standard 2 of 5 = Enable
Standard 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional Standard 2 of 5 check character.
DEFAULT Standard 2 of 5 Check Character Calculation = Disable
Standard 2 of 5 Check Character Calculation = Enable
148
WLS9600
Page 159
ENTER/EXIT PROGRAMMING MODE
Standard 2 of 5 Check Character Transmission
Standard 2 of 5 Check Character Transmission This feature enables/disables transmission of an optional Standard 2 of 5 check character.
Standard 2 of 5 Check Character Transmission = Don’t Send
DEFAULT Standard 2 of 5 Check Character Transmission = Send
Standard 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as good read.
Standard 2 of 5 Minimum Reads = 1
DEFAULT Standard 2 of 5 Minimum Reads = 2
Standard 2 of 5 Minimum Reads = 3
Standard 2 of 5 Minimum Reads = 4
Product Reference Guide
149
Page 160
Standard 2 of 5
ENTER/EXIT PROGRAMMING MODE
Standard 2 of 5 Decoding Level The Standard 2 of 5 Decoding Level feature is set using "2 of 5 Decoding Level" on page 142.
Standard 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set.
DEFAULT Standard 2 of 5 Length Control = Variable Length
Standard 2 of 5 Length Control = Fixed Length
150
WLS9600
Page 161
ENTER/EXIT PROGRAMMING MODE
Standard 2 of 5 Set Length 1
Standard 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Standard 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s check and data characters. The length can be set from 1 to 50 characters. Table 10 provides some examples for setting Length 1. See page 242 if you want detailed instructions on setting this feature. Table 10. Standard 2 of 5 Length 1 Setting Examples STEP
ACTION
1
Desired Setting
EXAMPLES 01 Character
07 Characters
15 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING
4
Scan Two Characters From Appendix D, Keypad
5
‘0’ and ‘1’
‘0’ and ‘7’
‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
Select Standard 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
Product Reference Guide
08 = Length 1 is 8 Characters
151
Page 162
Standard 2 of 5
ENTER/EXIT PROGRAMMING MODE
Standard 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Standard 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check and data characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 11 provides examples for setting Length 2. See page 243 for detailed instructions on setting this feature. Table 11. Standard 2 of 5 Length 2 Setting Examples STEP
ACTION
EXAMPLES
1
Desired Setting (pad with leading zeroes)
00 (Ignore This Length)
07 Characters
15 Characters
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT STANDARD 2 OF 5 LENGTH 2 SETTING
4 5
Scan Two Characters From Appendix D, Keypad
‘0’ and ‘0’
‘0’ and ‘7’
‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
Select Standard 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
152
50 = Length 2 is 50 Characters
WLS9600
Page 163
ENTER/EXIT PROGRAMMING MODE
Standard 2 of 5 Character Correlation
Standard 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
DEFAULT Standard 2 of 5 Character Correlation = Disable
Standard 2 of 5 Character Correlation = Enable
Standard 2 of 5 Stitching This option enables/disables stitching for Standard 2 of 5 labels. When parts of a Standard 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
DEFAULT Standard 2 of 5 Stitching = Disable
Standard 2 of 5 Stitching = Enable
Product Reference Guide
153
Page 164
Industrial 2 of 5
ENTER/EXIT PROGRAMMING MODE
INDUSTRIAL 2 OF 5 The following options apply to the Industrial 2 of 5 symbology.
Industrial 2 of 5 Enable/Disable Enables/Disables ability of reader to decode Industrial 2 of 5 labels.
DEFAULT Industrial 2 of 5 = Disable
Industrial 2 of 5 = Enable
Industrial 2 of 5 Check Character Calculation Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.
DEFAULT Industrial 2 of 5 Check Character Calculation = Disable
Industrial 2 of 5 Check Character Calculation = Enable
154
WLS9600