Page 55
USB-OEM INTERFACE
USB-OEM DEVICE USAGE on page 46 INTERFACE OPTIONS on page 46
Feature settings for USB interfaces differ depending upon which host type the reader will be connected with. Use the feature settings in this chapter to specifically configure for the USBOEM interface. Other USB interfaces are included in the appropriate chapter for their host type. Reference Appendix B, Standard Defaults for a listing of standard factory settings.
Product Reference Guide
45
Page 56
ENTER/EXIT PROGRAMMING MODE
USB-OEM Device Usage The USB-OEM protocol allows for the reader to be identified as one of two different types of barcode scanners. Depending on what other scanners you may already have connected to a USB-OEM POS, you may need to change this setting to enable all devices to communicate. Options are: • Table Top Scanner • Handheld Scanner It may be necessary to switch device usage when connecting two readers/scanners of the same type to a POS system.
USB-OEM Device Usage = Table Top Scanner
DEFAULT USB-OEM Device Usage = Handheld Scanner
Interface Options This feature provides for an interface-specific control mechanism.
Obey Scanner Configuration Host Commands
DEFAULT Ignore Scanner Configuration Host Commands
46
WLS9600
Page 57
WAND EMULATION INTERFACE
WAND SIGNAL SPEED on page 48 WAND POLARITY on page 48 WAND IDLE STATE on page 49 TRANSMIT NOISE on page 49 LABEL SYMBOLOGY CONVERSION on page 50 This chapter provides feature/settings configuration for the Wand Emulation interface. Reference Appendix B, Standard Defaults for a listing of standard factory settings.
Product Reference Guide
47
Page 58
ENTER/EXIT PROGRAMMING MODE
Wand Signal Speed This feature specifies the speed of the Wand output signal per nominal bar or space. Choices are: • 330 microseconds • 660 microseconds
Wand Signal Speed = 330ms
DEFAULT Wand Signal Speed = 660ms
Wand Polarity This option specifies the polarity of the Wand output signal. Choices are: • Quiet zones and spaces are high, bars are low • Quiet zones and spaces are low, bars are high
TTL logic levels: 0V <= Low <= 0.7V 2.4V <= High <= 5.25V
Wand Polarity = Quiet Zones & Spaces High, Bars Low
DEFAULT Wand Polarity = Quiet Zones & Spaces Low, Bars High
48
WLS9600
Page 59
ENTER/EXIT PROGRAMMING MODE
Wand Idle State
Wand Idle State This feature specifies the level of the Wand output signal when the reader is idle. TTL logic levels: 0V <= Low <= 0.7V 2.4V <= High <= 5.25V
Wand Idle State = Low
DEFAULT Wand Idle State = High
Transmit Noise This option specifies the leading/trailing noise for the Wand interface.
DEFAULT Transmit Noise = Disable
Transmit Noise = Transmit leading noise
Transmit Noise = Transmit trailing noise
Transmit Noise = Transmit leading and trailing noise
Product Reference Guide
49
Page 60
ENTER/EXIT PROGRAMMING MODE
Label Symbology Conversion When this feature is enabled for the Wand Emulation interface, all barcode labels are converted to a single symbology. Options are: • No conversion • Convert to Code 39 symbology • Convert to Code 39 Full ASCII • Convert to Code 128 symbology
DEFAULT Label Symbology Conversion = No conversion
Label Symbology Conversion = Convert to Code 39
Label Symbology Conversion = Convert to Code 39 Full ASCII
Label Symbology Conversion = Convert to Code 128
50
WLS9600
Page 61
DATA FORMAT GLOBAL PREFIX/SUFFIX on page 52 GLOBAL AIM ID on page 53 GS1-128 AIM ID on page 54 LABEL ID starting on page 55 • Label ID: Pre-loaded Sets • Label ID: Set Individually Per Symbology • Label ID Control • Label ID Symbology Selection • Set Global Mid Label ID Characters
CASE CONVERSION on page 64 CHARACTER CONVERSION on page 64
The features in this chapter can be used to build specific user-defined data into a message string. See “References” starting on page 244 for more detailed instructions on setting these features.
Product Reference Guide
51
Page 62
ENTER/EXIT PROGRAMMING MODE
Global Prefix/Suffix This option sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to FF. The characters may be added as a prefix (in a position before the barcode data, also called a header) and/or as a suffix (in a position following the barcode data, also called a footer). See page 245 for more detailed instructions on setting this feature. To configure this feature, scan the ENTER/EXIT PROGRAMMING MODE barcode above to place the unit in Programming Mode, then the “Set Global Prefix” or “Set Global Suffix,” barcode followed by the digits (in hex) from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). If less than the expected string of 20 characters are selected, scan the ENTER/EXIT barcode to terminate the string. Exit programming mode by scanning the ENTER/EXIT barcode again.
Set Global Prefix
Set Global Suffix
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
52
No Global Prefix Global Suffix = 0x0D (CR)
WLS9600
Page 63
ENTER/EXIT PROGRAMMING MODE
Global AIM ID
Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types.
AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned barcode data. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), followed by... • A code character (see the table below), followed by... • A modifier character (the modifier character is symbol dependent). SYMBOLOGY
CHAR
SYMBOLOGY
CHAR
UPC/EAN
Ea
Code 128/GS1-128
C
Code 39 and Code 32
A
DataBar Omnidirectional, DataBar Expanded e
Codabar
F
Standard 2 of 5
S
Interleaved 2 of 5
I
ISBN
Xb
Code 93
G
Code 11
H a. UPC-A and UPC-E labels are converted to EAN 13 when adding AIM IDs. b. ISBN (X with a 0 modifier character)
DEFAULT Global AIM ID = Disable
Global AIM ID = Enable
Product Reference Guide
53
Page 64
ENTER/EXIT PROGRAMMING MODE
GS1-128 AIM ID If Global AIM ID is disabled, the AIM ID for GS1-128 can be enabled/disabled independently. The AIM ID for GS1-128 is a ]C1, ]C2 or ]C3. AIM IDs for other symbologies can be enabled/disabled independently as well. Contact Customer Support for assistance
GS1-128 AIM ID = Disable
DEFAULT GS1-128 AIM ID = Enable
54
WLS9600