Page 55

USB-OEM INTERFACE

USB-OEM DEVICE USAGE on page 46 INTERFACE OPTIONS on page 46

Feature settings for USB interfaces differ depending upon which host type the reader will be connected with. Use the feature settings in this chapter to specifically configure for the USBOEM interface. Other USB interfaces are included in the appropriate chapter for their host type. Reference Appendix B, Standard Defaults for a listing of standard factory settings.

Product Reference Guide

45

Page 56

ENTER/EXIT PROGRAMMING MODE

USB-OEM Device Usage The USB-OEM protocol allows for the reader to be identified as one of two different types of barcode scanners. Depending on what other scanners you may already have connected to a USB-OEM POS, you may need to change this setting to enable all devices to communicate. Options are: • Table Top Scanner • Handheld Scanner It may be necessary to switch device usage when connecting two readers/scanners of the same type to a POS system.

USB-OEM Device Usage = Table Top Scanner

DEFAULT USB-OEM Device Usage = Handheld Scanner

Interface Options This feature provides for an interface-specific control mechanism.

Obey Scanner Configuration Host Commands

DEFAULT Ignore Scanner Configuration Host Commands

46

WLS9600

Page 57

WAND EMULATION INTERFACE

WAND SIGNAL SPEED on page 48 WAND POLARITY on page 48 WAND IDLE STATE on page 49 TRANSMIT NOISE on page 49 LABEL SYMBOLOGY CONVERSION on page 50 This chapter provides feature/settings configuration for the Wand Emulation interface. Reference Appendix B, Standard Defaults for a listing of standard factory settings.

Product Reference Guide

47

Page 58

ENTER/EXIT PROGRAMMING MODE

Wand Signal Speed This feature specifies the speed of the Wand output signal per nominal bar or space. Choices are: • 330 microseconds • 660 microseconds

Wand Signal Speed = 330ms

DEFAULT Wand Signal Speed = 660ms

Wand Polarity This option specifies the polarity of the Wand output signal. Choices are: • Quiet zones and spaces are high, bars are low • Quiet zones and spaces are low, bars are high

TTL logic levels: 0V <= Low <= 0.7V 2.4V <= High <= 5.25V

Wand Polarity = Quiet Zones & Spaces High, Bars Low

DEFAULT Wand Polarity = Quiet Zones & Spaces Low, Bars High

48

WLS9600

Page 59

ENTER/EXIT PROGRAMMING MODE

Wand Idle State

Wand Idle State This feature specifies the level of the Wand output signal when the reader is idle. TTL logic levels: 0V <= Low <= 0.7V 2.4V <= High <= 5.25V

Wand Idle State = Low

DEFAULT Wand Idle State = High

Transmit Noise This option specifies the leading/trailing noise for the Wand interface.

DEFAULT Transmit Noise = Disable

Transmit Noise = Transmit leading noise

Transmit Noise = Transmit trailing noise

Transmit Noise = Transmit leading and trailing noise

Product Reference Guide

49

Page 60

ENTER/EXIT PROGRAMMING MODE

Label Symbology Conversion When this feature is enabled for the Wand Emulation interface, all barcode labels are converted to a single symbology. Options are: • No conversion • Convert to Code 39 symbology • Convert to Code 39 Full ASCII • Convert to Code 128 symbology

DEFAULT Label Symbology Conversion = No conversion

Label Symbology Conversion = Convert to Code 39

Label Symbology Conversion = Convert to Code 39 Full ASCII

Label Symbology Conversion = Convert to Code 128

50

WLS9600

Page 61

DATA FORMAT GLOBAL PREFIX/SUFFIX on page 52 GLOBAL AIM ID on page 53 GS1-128 AIM ID on page 54 LABEL ID starting on page 55 • Label ID: Pre-loaded Sets • Label ID: Set Individually Per Symbology • Label ID Control • Label ID Symbology Selection • Set Global Mid Label ID Characters

CASE CONVERSION on page 64 CHARACTER CONVERSION on page 64

The features in this chapter can be used to build specific user-defined data into a message string. See “References” starting on page 244 for more detailed instructions on setting these features.

Product Reference Guide

51

Page 62

ENTER/EXIT PROGRAMMING MODE

Global Prefix/Suffix This option sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to FF. The characters may be added as a prefix (in a position before the barcode data, also called a header) and/or as a suffix (in a position following the barcode data, also called a footer). See page 245 for more detailed instructions on setting this feature. To configure this feature, scan the ENTER/EXIT PROGRAMMING MODE barcode above to place the unit in Programming Mode, then the “Set Global Prefix” or “Set Global Suffix,” barcode followed by the digits (in hex) from the Alphanumeric characters in Appendix D, Keypad representing your desired character(s). If less than the expected string of 20 characters are selected, scan the ENTER/EXIT barcode to terminate the string. Exit programming mode by scanning the ENTER/EXIT barcode again.

Set Global Prefix

Set Global Suffix

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

52

No Global Prefix Global Suffix = 0x0D (CR)

WLS9600

Page 63

ENTER/EXIT PROGRAMMING MODE

Global AIM ID

Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types.

AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned barcode data. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), followed by... • A code character (see the table below), followed by... • A modifier character (the modifier character is symbol dependent). SYMBOLOGY

CHAR

SYMBOLOGY

CHAR

UPC/EAN

Ea

Code 128/GS1-128

C

Code 39 and Code 32

A

DataBar Omnidirectional, DataBar Expanded e

Codabar

F

Standard 2 of 5

S

Interleaved 2 of 5

I

ISBN

Xb

Code 93

G

Code 11

H a. UPC-A and UPC-E labels are converted to EAN 13 when adding AIM IDs. b. ISBN (X with a 0 modifier character)

DEFAULT Global AIM ID = Disable

Global AIM ID = Enable

Product Reference Guide

53

Page 64

ENTER/EXIT PROGRAMMING MODE

GS1-128 AIM ID If Global AIM ID is disabled, the AIM ID for GS1-128 can be enabled/disabled independently. The AIM ID for GS1-128 is a ]C1, ]C2 or ]C3. AIM IDs for other symbologies can be enabled/disabled independently as well. Contact Customer Support for assistance

GS1-128 AIM ID = Disable

DEFAULT GS1-128 AIM ID = Enable

54

WLS9600