Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of Operating Instructions CLX490 Compact OMNI Scanner for Bar Codes

Manual · Sick

Operating Instructions CLX490 Compact OMNI Scanner for Bar Codes

Manual158 pagesPDF 3.4 MB

Operating instructions for the SICK CLX490 Compact OMNI bar code scanner: mounting, wiring, CLV-Setup configuration and troubleshooting.

Download the PDF3.4 MB

Covers · 1 model

The models it covers

Summary

What is in it

The operating instructions for the SICK CLX490 Compact OMNI Scanner, an omnidirectional fixed-mount bar code scanner, in the CLX490-0010 and CLX490-0011 (with heater) variants. It covers safety, product design and autofocus, mounting and adjusting the scanner, electrical installation with SICK connection modules, startup and configuration with the CLV-Setup software, operating modes, maintenance, troubleshooting and error messages, and data sheets. The appendix adds reading field diagrams, the external parameter memory, optional heating and ordering information.

Its parts

  1. Notes on this document
  2. Safety information
  3. Product description
  4. Installation
  5. Electrical installation
  6. Operation
  7. Maintenance
  8. Troubleshooting
  9. Technical data

From the manual

Key facts from this manual

Each line names its page in the PDF.

Operating instructions for the SICK CLX490 Compact OMNI Scanner for bar codes, covering the CLX490-0010 and the CLX490-0011 with heater. It explains installation, electrical connection, configuration with the CLV-Setup program, operation, maintenance and troubleshooting, with technical data and ordering information for accessories.

Read for this summary: pages 1 to 3, 19 to 20, 40, 44 to 45, 90 to 91, 103 to 104 and 139 to 141 of 158.

Device
Compact OMNI laser scanner for bar codes, red light (650 nm), autofocus p. 1, 103
Variants
CLX490-0010 (order no. 1019318, no heater); CLX490-0011 (order no. 1019319, with heater) p. 139
Power, CLX490-0010
CLX490-0010: 18 to 30 V DC, typically 11 W, max. 16 W p. 103
Power, CLX490-0011
CLX490-0011: 24 V DC +20 %/-10 %, typically 75 W, max 90 W p. 104
Connectors
15-pin D Sub HD plug (Host/Term) and 15-pin D Sub HD socket (I/O) p. 44, 103
Data interfaces
Host RS 232 or RS 422/485, 300 to 57,600 bd; auxiliary RS 232, 9,600 bd; CAN 20 kbit/s to 1 Mbit/s, CANopen p. 103
Inputs and outputs
6 optodecoupled switching inputs (Sensor, IN 0 to IN 4), max. +30 V; 4 PNP short-circuit-proof outputs (Result 1 to Result 4) p. 103
Scanning and resolution
600 to 1,200 Hz; resolution typically 0.30 to 1.0 mm p. 103
Bar code types
Code 39, Code 128, Code 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved p. 103
Operating temperature
CLX490-0010: 0 to +40 °C; CLX490-0011: -30 to +35 °C p. 104
Connection modules
One CLX without heater: AMV60-011 (no. 1017134, 18 to 30 V DC), AMS60-013 (no. 1017139, 230 V AC), AMS60-012 (no. 1017140, 115 V AC); two CLX: AMV30-071 (no. 1017391) p. 19, 20
Cables
2020302 Host/Term or I/O connection cable (2 per CLX); 2020264 I/O and power cable, 3 m, one open end; 2014054 RS 232 null modem cable p. 20, 141
Parameter memory
2020307 connector cover with parameter memory (EEPROM), IP 65, with two connection cables p. 141
Software
Firmware V 5.0 RA32; CLV-Setup configuration software for Windows, V 4.4 QF16 p. 2

What this manual walks you through

  • What is delivered with the scanner p. 19
  • System requirements: connection modules, power pack, PC and cables p. 19, 20
  • Choosing prefabricated cables for each connection module p. 40
  • Pin assignment of the Host/Term plug and I/O socket p. 44, 45
  • Reading system error codes on the auxiliary interface p. 90
  • LED error indications for the external parameter memory p. 91
  • Technical data of the CLX490-0010 and CLX490-0011 p. 103, 104
  • Ordering scanners, mounting accessories, connection modules, bus modules and cables p. 139, 140, 141

Good to know

  • CLX490-0011: the heater gives a power-on delay of 35 to 40 min at 24 V DC and -30 °C. p. 104
  • Without heater, all connections need copper wire of at least 0.15 mm2; with heater, power terminals need at least 0.75 mm2 over at most 10 m. p. 40
  • A non-SICK power pack must give 18 to 30 V DC and at least 20 W; for the heated version, 24 V DC and at least 100 W. p. 20
  • Coded error messages appear only on the auxiliary interface. p. 90
  • By default the laser diode shuts off after 10 min. p. 103

Questions this manual answers

What is the difference between the SICK CLX490-0010 and CLX490-0011?

The CLX490-0011 has a heater: it runs on 24 V DC, draws typically 75 W and works from -30 to +35 °C. p. 104

What voltage does the CLX490 scanner need?

The CLX490-0010 runs on 18 to 30 V DC, typically 11 W and at most 16 W. p. 103

What does CLX490 error CLV SYS-Failure 051 mean?

Error key 051 means the mirror wheel speed is out of tolerance; if it comes back after a restart, the manual says to contact SICK Service. p. 90

What software is used to set up the CLX490?

The CLV-Setup program for Windows, with its CLV-Setup Help, supplied on the CD-ROM (no. 2029112). p. 19

Which cable connects a PC to the CLX490?

A 3-core RS 232 null modem cable with two 9-pin D Sub sockets, such as no. 2014054, to the auxiliary interface in the connection module. p. 20

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1 Notes on this document13
    1. 1.1 Purpose13
    2. 1.2 Target audience13
    3. 1.3 Information content13
    4. 1.4 Symbols14
  2. 2 Safety information15
    1. 2.1 Authorized users15
    2. 2.2 Intended use15
    3. 2.3 General safety instructions and protection measures16
    4. 2.4 Quick stop and quick restart18
    5. 2.5 Environmental information18
  3. 3 Product description19
    1. 3.1 Design19
    2. 3.2 Method of operation22
    3. 3.3 Indicators and control elements25
  4. 4 Installation29
    1. 4.1 Installation sequence29
    2. 4.2 Preparations29
    3. 4.3 Mounting and adjusting the device34
    4. 4.4 Mounting the external components36
    5. 4.5 Dismantling the device38
  5. 5 Electrical installation39
    1. 5.1 Installation sequence39
    2. 5.2 Electrical connections and cables40
    3. 5.3 Connector pin assignment44
    4. 5.4 Preparations for electrical installation46
    5. 5.5 Electrical installation procedur51
  6. 6 Operation59
    1. 6.1 Overview of steps for starting up the CLX59
    2. 6.2 Default settings59
    3. 6.3 Quick start61
    4. 6.4 Configuring (parameterization) the CLX62
    5. 6.5 Operating modes and outputing the reading result72
    6. 6.6 CLX messages83
    7. 6.7 Switching off the CLX84
  7. 7 Maintenance85
    1. 7.1 Maintenance during operation85
    2. 7.2 Cleaning the CLX85
    3. 7.3 Checking the incremental encoder87
    4. 7.4 Disposal87
30 more lines, from page 89 on
  1. 8 Troubleshooting89
    1. 8.1 Overview of the possible errors and malfunctions89
    2. 8.2 Monitoring error and malfunctions89
    3. 8.3 Error messages90
    4. 8.4 ST error status in the reading result of a bar code95
    5. 8.5 Troubleshooting97
    6. 8.6 SICK Support102
  2. 9 Technical data103
    1. 9.1 Data sheet CLX490-0010 Compact OMNI Scanner103
    2. 9.2 Data sheet CLX490-0011 Compact OMNI Scanner104
    3. 9.3 Dimensioned drawing of the CLX104
  3. 10 Appendix105
    1. 10.1 Overview105
    2. 10.2 Specification diagrams105
    3. 10.3 Installing and operating the external parameter memory112
    4. 10.4 Optional heating116
    5. 10.5 System messages118
    6. 10.6 Installing and operating the "CLV-Setup" program119
    7. 10.7 Configuring a CLX with command strings129
    8. 10.8 Calculating parameter values for setting the CLX131
    9. 10.9 Tables132
    10. 10.10 Special applications and procedures133
    11. 10.11 Replacing a CLX (copying the parameter set)137
    12. 10.12 Ordering information139
    13. 10.13 Dimensioned drawings of the accessories143
    14. 10.14 Supplementary documentation144
    15. 10.15 Glossary145
    16. 10.16 EC Declaration of Conformity151
    17. 10.17 Index153
    18. 10.18 Bar code example157

From the PDF’s own bookmarks.

The whole text · 18 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6
  2. Pages 7 to 127-12
  3. Pages 13 to 1813-18
  4. 3 Product description19-28
  5. 4 Installation29-38
  6. 5 Electrical installation, pages 39 to 4839-48
  7. 5 Electrical installation, pages 49 to 5849-58
  8. 6 Operation, pages 59 to 6759-67
  9. 6 Operation, pages 68 to 7668-76
  10. 6 Operation, pages 77 to 8477-84
  11. 7 Maintenance85-88
  12. 8 Troubleshooting89-102
  13. Pages 103 to 112103-112
  14. Pages 113 to 122113-122
  15. Pages 123 to 132123-132
  16. Pages 133 to 142133-142
  17. Pages 143 to 152143-152
  18. Pages 153 to 158153-158

The file

Revision and size

Revision8009237/RB47/2007-08-03
PublisherSICK AG
Pages158
PDF3.4 MB
TextText from the PDF itself; pages 1 and 158 are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 158

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 158
Page 2
Page 2of 158
Page 3
Page 3of 158

More documents · 1

For the same models