The text of a manual · part 8 of 18
Operating Instructions CLX490 Compact OMNI Scanner for Bar Codes: 6 Operation, pages 59 to 67
Pages 59 to 67 of 158, from Operating Instructions CLX490 Compact OMNI Scanner for Bar Codes
The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick CLX490
Page 59
Operating Instructions
Operation
Chapter 6
CLX490
6
Operation 6.1
Overview of steps for starting up the CLX
•
Start up the CLX with the factory default settings (quick start). With this configuration, the CLX can be operated without being connected to a PC.
•
Connect the PC (see Chapter 5.5.6 Connecting the PC, Page 5-15) and install the CLVSetup program (see Chapter 10.6 Installing and operating the "CLV-Setup" program, Page 10-15).
•
Configure the CLX for the desired application.
6.2
Default settings
Table 6-1 contains an overview of the factory default settings for the CLX. The default parameters are such that the CLX can be put into operation either straight away or following a few minor adjustments. A PC does not need to be connected to start up the CLX with the default settings. The default settings are stored permanently both in the ROM of the CLX and in the CLV-Setup database. They can be loaded to the RAM of the CLX at any time and displayed in the tabs of the CLV-Setup program. Displaying and printing out a complete set of default settings in CLV-Setup: 1.
To save the current settings in the parameter set: Choose FILE and SAVE AS, and enter a file name in the dialog box that appears. CLV-Setup saves the current settings in a configuration file with the extension "*.scl".
2.
Click in the toolbar. CLV-Setup loads the default settings from its internal database and displays them in the tabs.
3.
Click in the toolbar. The PRINT FILE dialog box is displayed.
4.
If desired, a comment can be entered in the input field for the header of the printout. Confirm the entry with OK. The PRINT dialog box for configuring the printer then is displayed.
5.
Make the appropriate entries in the dialog box and confirm these with OK.
CLV-Setup prints out the complete set of default settings in the form of a table. The header contains the company and user names that were entered during the CLV-Setup installation routine.
8009237/RB47/2007-08-03
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-1
Page 60
Chapter 6
Operation
Operating Instructions CLX490 Compact OMNI Scanner
6.2.1
Default settings of the CLX490
Parameter
Default setting
Decoder
SMART/standard
Active codes types
Code 39, 2/5 Interleaved, Code 128
Code length
Freely assignable (2/5 Interleaved: interval 4 to 50 characters)
Start/stop ratio
Automatic
No. of multiple reads
3
Min./max. no. codes
1
Scanning frequency
800 Hz
Distance measurement
Active
Background
Default (2,200 mm along entire distance profile)
Autofocus mode
Minimum distance
Range Focus control trigger Reading pulse source
400 to 1,800 mm Autofocus, switchover immediately (synchronously) Start: "Sensor" switching input (active: high); end: "Sensor" switching input
"IN 0 to IN 4" switching inputs
Focus position changeover (without meaning for autofocus function)
”Sensor” switching input
Start and end of reading pulse (level: active high), debouncing 20 to 30 ms
Switching outputs Status output function
Not inverted; pulse duration: 100 ms Result 1: Device Ready (static); Result 2: Good Read; Result 3: No Read; Result 4: Match 1
CLX arrangement
Stand-alone
Read result output
Host interface
Device number
1
Start option
Load the parameter set of the external parameter memory
Host interface (type)
RS 422/485
Protocol
NAK; start character: STX, stop character: ETX
Transmission rate
9,600 bd
Data format
8 data bits, no parity, 1 stop bit
Output format
Good Read: Header: blank, Code-Info/Separator: blank, Splitter: blank, Terminator: blank Reading data on No Read: output: yes, contents: Code-Info/Separator and Error string Error string: NOREAD
Output sorting
In accordance with reading angle
Output time
Read result: end of the read interval
Test string Auxiliary interface Function
Code-Info/Separator: after code
Not activated RS 232, 9,600 bd, 8 data bits, no parity, 1 stop bit (values cannot be changed) Reading diagnosis
Table 6-1: Extract CLX490: Default parameter settings
6-2
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 61
Operating Instructions
Operation
Chapter 6
CLX490
6.3
Quick start
A PC does not need to be connected when the CLX is operated with the factory default settings. Code 39, 2/5 Interleaved, and Code 128 are the default code types enabled (free code lenght, 2/5 Interleaved: interval 4 to 50 characters). 6.3.1
Switching the CLX on for the first time with the factory default settings
1.
Connect the CLX to the AMV/S60 Connection Module using the two cables no. 2020302.
2.
Connect the reading pulse sensor (e. g. photoelectric reflex switch, switch) to the "Sensor" switching input of the CLX via the AMV/S60 (see Chapter 5.5.7 Connecting the switching inputs, Page 5-16).
3.
Switch on the power supply of the AMV/S60. The CLX starts. The "Device Ready" LED lights up. The "Result 1" ("Device Ready") output switches. CLX with external parameter memory connected (default: Start with ext. parameters): If an external parameter memory in the connector cover containing a corresponding parameter set is connected to the CLX, the "Device Ready" LED blinks for 10 s when the device starts up correctly and then lights up constantly. If the external parameter memory in the connector cover is empty, the CLX copies its parameter set to the external parameter memory. Then the "Device Ready" LED lights up. The CLX is ready for operation.
4.
Start the reading pulse: block the light path of the photoelectric switch or close the switch. The "Laser On" LED lights up. The CLX switches the laser diode on and the red scan line appears as a cross.
5.
Present the bar code pattern (Fig. 6-1) to the CLX at the reading distance specified in Table 6-2, Page 6-4. The scan line must not hit any object in a distance closer to the CLX than the represented bar code (default setting: autofocus mode "Minimum distance").
6.
Align the bar code in such a way that the red scan line is almost at a 90° angle to the bars.
7.
End the reading pulse: unblock the light path of the photoelectric switch or open the switch. The "Laser On" LED is extinguished. The CLX switches the laser diode off. The CLX confirms that the bar code was read successfully (the "Result" LED lights up for 100 ms). The "Result 2" ("Good Read") output is switched for a duration of 100 ms.
The CLX can now be operated with the factory default settings. The device can be switched off without the configuration data being lost as no changes have been made to the parameter set.
0
Fig. 6-1:
8009237/RB47/2007-08-03
1
2
3
4
1
2
3
4
5
Bar code pattern (Code 39; module width 0.35 mm; Print ratio 2:1)
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-3
Page 62
Chapter 6
Operation
Operating Instructions CLX490 Compact OMNI Scanner
Device type
Reading distance
CLX490 (all variants)
approx. 1,000 mm
Table 6-2: Reading distances for default settings
6.4
Configuring (parameterization) the CLX
The CLX adapts to the reading situation locally with the configuration. The read, evaluation and output characteristics can, therefore, be parameterized as required on the basis of the factory default settings or an application-specific CLX parameter set that has already been created. The CLX supports two different configuration methods: •
Configuration via the "CLV-Setup" program (parameter values are set via the serial interface)
•
Configuration via command strings (parameter values are set via the serial interface) See Chapter 10.7 Configuring a CLX with command strings, Page 10-25.
In the Parameterization mode, the CLX outputs no reading result. 6.4.1
Configuring the CLX with CLV-Setup
To be able to use CLV-Setup, a PC has to be connected and the program installed on it. The procedure for connecting the PC to the CLX is described in Chapter 5.5.6 Connecting the PC, Page 5-15. The procedures for installing and starting the "CLV-Setup" program and for starting and operating the user interface are described in the Appendix (Chapter 10.6 Installing and operating the "CLV-Setup" program, Page 10-15). Transferring a parameter set between CLV-Setup and the CLX Upload When the CLX is being parameterized, CLV-Setup runs in the offline mode. To be able to modify the current parameter set of the CLX, this first has to be loaded to CLV-Setup from the CLX. This procedure is referred to as an upload ("Upload from CLV" in the CLX490 menu or [F3] key) during which CLV-Setup always loads a complete copy of the current CLX parameter set. This parameter set remains unchanged until it is overwritten by CLV-Setup. With the help of the context menu (right mouse button), only the parameter just edited can be loaded ("Upload parameter") or from version 3.6 all parameters of one tab or one dialog box ("Upload parameters of this view") from the CLX’s memory (RAM). Download Changes made to the current parameter set in CLV-Setup do not take effect until the parameter set has been transferred to the CLX. CLV-Setup always sends a copy of the complete parameter set to the CLX, i. e. all of the existing parameter values in the CLX are overwritten. The procedure for transferring and saving the parameter values in the CLX is referred to as a download ("Download to CLV" in the CLX490 menu or [F4] key). With the help of the context menu (right mouse button), only the parameter just edited ("Download parameter") or from version 3.6 all parameters of one tab or one dialog box ("Download parameters of this view") will be temporarily loaded into the CLX’s memory (RAM). To finish the parametrization done by this way all parameters must be download again to the CLX with the "Permanent" option.
6-4
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 63
Operating Instructions
Operation
Chapter 6
CLX490
Loading a complete CLX parameter set (upload) ¾
Click in the toolbar or press [F3] key. CLV-Setup loads the current CLX parameter set from the RAM of the CLX to its database and displays the values in the tabs. The "Device Ready" LED is extinguished during the upload.
If the "CLV-Setup" program does not recognize parameters transferred during the upload, it outputs a warning message. Unknown parameters can be edited in the EXTRAS tab by following the conventions for command strings. When the parameter set is then saved, these parameters are also saved. Transfering and saving a complete CLX parameter set (download) 1.
Click in the toolbar or press [F4] key. The "Device Ready" LED is extinguished. CLV-Setup copies the parameter set to the RAM of the CLX. The DOWNLOAD PARAMETERS dialog box with the storage options is then displayed. PERMANENT: CLV-Setup copies the parameter set to the RAM and to the EEPROM of the CLX. TEMPORARY: CLV-Setup copies the parameter set to the RAM only. The changes are lost when the CLX supply voltage is switched off.
2.
Confirm the dialog box with the desired storage option. The "Device Ready" LED lights up again.
The new parameter set is stored in the CLX either permanently or temporarily. CLX with external parameter memory If the parameter set was downloaded and stored permanently, CLV-Setup opens a further dialog box for adjusting the parameter set in the external memory, if the start option is set to START WITH EXTERNAL PARAMETERS. ¾
Choose the COPY NOW INTERNAL PARAMETER SET TO EXTERNAL MEMORY option. CLV-Setup then instructs the CLX to copy the new parameter set to the external memory. The "Device Ready" LED lights up again.
The internal and external parameter sets are now identical. See also Chapter 10.3.5 Adjusting the parameter set in the external parameter memory after it has been downloaded to the CLX, Page 10-10. Saving a parameter set in CLV-Setup 1.
To save the modified parameter set as a new configuration file in CLV-Setup, or to overwrite an existing file, choose FILE and SAVE AS. The SAVE AS ... dialog box is then displayed.
2.
Enter the file name in the dialog box (file name extension "*.scl") and confirm the entry.
The new parameter set is now stored in CLV-Setup in the subdirectory "data".
8009237/RB47/2007-08-03
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-5
Page 64
Operation
Chapter 6
Operating Instructions CLX490 Compact OMNI Scanner
6.4.2
Function of the tabs in CLV-Setup (overview)
Reading Configuration This tab and further dialog boxes are used to set the following: •
Scanning frequency
•
Start/stop ratio
•
Reading area (reading angle limits or three-dimensional reading space when the conveyor is running)
•
Autofocus mode (object distance measurement, preference focus distance, delay of focus chance, depth of field optimization, autofocus space)
•
Reading distance configuration for event-controlled focus control (focus position, assignment table)
•
Trigger source for the focus control (if event-controlled)
•
Adjustment to bar code characteristics
Device Configuration This tab and further dialog boxes are used to set the following: •
Device number
•
Source of the reading trigger mode
•
Laser timeout
•
Output time of the reading result referred to the start of the reading interval
•
Scanner position parameters (position of the CLX in the space)
•
Tracking parameters
•
Object polling parameters
•
Output filter of the reading result (host interface)
•
Physical arrangement for data output via the host interface (stand-alone, master/slave)
•
Functional assignment of the "IN 4" switching input
•
Functional assignments of the "Result 1 to Result 4" switching outputs
•
Start option for accessing the parameter set
•
Match code
Code Configuration This tab and other further dialog boxes are used to set the following:
Recommendation
6-6
•
Type of active decoder (SMART, SMART/Standard or Standard decoder)
•
Evaluation routines for individual code types
•
Number of identical reads (multiple reads)
•
Minimum and maximum number of bar codes to be read/output
•
Kind of Start/Stop recognition
•
Activation of the comparison of the reading angle for the separation of identical bar codes
•
Special parameters of the SMART decoder (e. g. for OTS mode)
To enhance the reading reliability with fast applications, only activate those code types and code lengths that are actually relevant.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 65
Operation
Operating Instructions
Chapter 6
CLX490
Host Interface This tab and other further dialog boxes are used to set the following: •
Destination of the result data strings (host interface or CAN interface)
•
Active physical interface (RS 422/485 or RS 232)
•
Data format and transmission rate
•
Data transmission protocol
•
Start and stop characters of the interface protocol
Data Strings This tab and other further dialog boxes are used to set the following: •
Data output format of the host interface (telegram format)
•
Constants and reading diagnosis data in the "Header", "Code-Info/separator", "Splitter" and "Terminator" blocks
•
Arrangement of the "Code-Info/separator" blocks in the data string
•
Output format for no reads and contents of the error string
•
Test string function (heartbeat)
•
Output sequence and sort criteria for reading more than one bar code per reading pulse
•
Format mask and its structure
•
Output format of an external data string forwarded as reading result
Auxiliary Interface This tab is used to change the following: •
Operating mode of the auxiliary interface
CAN Interface This tab and other further dialog boxes are used to change the following: •
CAN interface operating mode
•
Data transfer rate
•
Type of logical data connection of the connected CLX
•
Usage of the switch inputs/outputs of the CLX as CANopen Digital I/O
Extras This tab is used to edit parameters that were not recognized by CLV-Setup after an upload. Note
8009237/RB47/2007-08-03
CLV-Setup Online Help contains a detailed description of the functions of the parameters and their valid entries (see Chapter 10.6.8 CLV-Setup Help, Page 10-22 for calling up Help).
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-7
Page 66
Chapter 6
Operation
Operating Instructions CLX490 Compact OMNI Scanner
6.4.3
Guide to parameterization menu
Overview of parameterization steps •
Adjusting the optical read properties of the scanner
•
Configuring a read pulse timing
•
Adjusting the decoder’s evaluation properties
•
Adjusting the output properties (data, result status)
•
Specifying the auxiliary interface function (auxiliary interface)
•
Indicating the source of the parameter set for starting up (only with external parameter memory)
When the CLX is switched on for the first time, it is started with the factory default settings. The following parameters must then be set: a) Adjusting the optical reading properties •
6-8
Scanning frequency Ö READING CONFIGURATION tab Ö Reading Parameters
•
Blank zone Ö READING CONFIGURATION tab Ö Start/stop ratio
•
Poor quality bar code print Ö READING CONFIGURATION tab Ö Code label characteristics
•
Relative module width Ö READING CONFIGURATION tab Ö Code label characteristics
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 67
Operation
Operating Instructions
Chapter 6
CLX490
Parameterizing the autofocus mode (Part 1): Action
Settings
1. Activate autofocus mode
Ö READING CONFIGURATION tab FOCUS CONTROL
Ö Autofocus 2. Choose autofocus mode
AUTOFOCUS Ö MODE – Minimum distance or – Differential background or – Differential background and tracking see Table 6-4
3. Set up autofocus mode
AUTOFOCUS Ö AUTOFOCUS PARAMETERS Ö ADJUSTMENTS – Preference focus distance – Focus release Ö AUTOFOCUS LIMITS PARAMETERS – Autofocus limitation – Autofocus space (see Table 6-4) Ö AUTOFOCUS OPTIMIZATIONS PARAMETERS – Delay of focus change – Depth of field optimization – Object height passing in OTS mode – Distance measurement Ö ACTIVE – Source of distance information
4. Choose time of focusing (based on reading pulse)
FOCUS CONTROL Ö Inputs/Serial/Autofocus – Immediate or Synchronous – Latched
Table 6-3: Guide: Parameterizing the autofocus mode (Part 1)
Configuring autofocus function (Part 2): •
Area parameters Ö DEVICE CONFIGURATION tab Ö Scanner Positon Parameters and Tracking Parameters (only in OTS mode)
•
Teach-in/show ambient background Ö AUXILIARY menu Ö Device function
Parameter
Minimum Distance
Differential background
Differential background and tracking
Condition
1 object in reading field per reading interval
1 object in reading field per reading interval
No. of objects in the reading field per reading interval: ≥ 1
1. Limits: autofocus limitation
✖
❍
❍
2. Limits: autofocus space
–
❍
❍
3. Scanner position parameters (angles): angle alpha, beta, gamma
–
✖
✖
4. Scanner position parameters (coordinates): coordinates x, y, z
–
✖
✖
5. Tracking parameter: focus release point
–
–
✖
6. Teach-in background
–
❍
❍
✖ : required
❍: optional
Table 6-4: Guide: Parameterizing the autofocus function (Part 2)
8009237/RB47/2007-08-03
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-9