Page 68
Chapter 6
Operation
Operating Instructions CLX490 Compact OMNI Scanner
Parameterization the event-controlled focus control (alternative): Action
Settings
1. Activate focus control function (choose trigger source)
Ö READING CONFIGURATION tab Ö FOCUS CONTROL – Inputs/Serial or – Timer or – Static/No Trigger
2. Choose focus switchover point (referred to reading pulse)
FOCUS CONTROL
Ö Inputs/Serial – Immediate or Synchronous – Latched
3. Set up focus control
DISTANCE CONFIGURATION Ö Distance Configuration – Focus Position Ö Assignment Table – Index – Valid Configurations
4. In INPUTS/SERIAL trigger mode: choose function for "IN 4" switching input
Ö DEVICE CONFIGURATION tab Ö ASSIGNMENT IN 4 – Focus Control
Table 6-5: Guide: Parameterizing the event-controlled focus control
6-10
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 69
Operating Instructions
Operation
Chapter 6
CLX490 b) Parameterizing the reading trigger source: Action
Settings
1. Reading trigger: choose source for start
Ö DEVICE CONFIGURATION tab Ö Section READING TRIGGER SOURCE – Sensor Input (Active High) or – Sensor Input (Active Low) or – Serial Interface or – Free-running with Timeout or – OPC-Trigger (special application) or – OTS-Trigger (special application)
2. Trigger source "Sensor Input": Choose debouncing and response with firsttrigger
Ö READING TRIGGER PARAMETERS Ö DEBOUNCING SENSOR – Standard or – Fast Ö FIRST TRIGGER SENSOR – Dynamic or – Static
3. Trigger source "Serial Interface": choose trigger character
Ö READING TRIGGER PARAMETERS Ö SERIAL INTERFACE – Standard Trigger or – Single Character
4. Trigger source "Free-running": choose timeout
Ö READING TRIGGER PARAMETERS Ö END OF LABEL/FREE-RUNNING – Timeout
5. Reading trigger: choose source for end
Ö READING TRIGGER PARAMETERS Ö END OF READING INTERVAL – Generated by Trigger Source or – Timer or – Generated by "IN 4" switching input
Table 6-6: Guide: Parameterizing the reading trigger source
Parameterizising the laser timeout: Action
Settings
1. Choose laser timeout duration – or –
Ö DEVICE CONFIGURATION tab Ö READING TRIGGER PARAMETERS Ö LASER TIMEOUT – Duration
2. Deactivate laser timeout (The laser diode is always active, when triggered, independent of the pulse duration)
Ö LASER TIMEOUT – Click (deactivate) the control box INTERVAL ACTIVE
Table 6-7: Guide: Parameterizing the laser timeout c) Parameterizising the evaluation characteristics
8009237/RB47/2007-08-03
•
Choose decoder type Ö CODE CONFIGURATION tab Ö Decoder
•
Activate code types for evaluation Ö CODE CONFIGURATION tab Ö Codes and Edit Codes
•
Activate code comparison Ö DEVICE CONFIGURATION tab Ö Match Codes Parameters
•
Define output time of reading result Ö CODE CONFIGURATION tab Ö Output on Good Read
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-11
Page 70
Operation
Chapter 6
Operating Instructions CLX490 Compact OMNI Scanner
Separation of identical bar codes (same code type/identical contents) Number of bar codes per object
Stationary conveyor object
Moving conveyor object
Number n > 1: – Same code type – Contents different or identical
Ö CODE CONFIGURATION tab Ö CODE SUMMARIZATION section – Activate "Seperate codes
Ö CODE CONFIGURATION tab Ö CODE SUMMARIZATION section dependent on reading angle" – Min. distance between labels Ö NUMBER OF CODES section – Minimum – Maximum
– Activate "Seperate codes dependent on reading angle" – Min. distance between labels Ö NUMBER OF CODES section – Minimum – Maximum
Ö DEVICE CONFIGURATION tab Ö SCANNER POSITION PARAMETERS button Ö ANGLES section – Angle alpha Ö DISTANCE PER ENCODER PULSE section – value
Table 6-8: Guide: Parameterizing the separation of identical bar codes
Note
If the number n > 1, minimum distance between the bar codes on the object must be provided in the following cases: •
The SMART decoder is to read bar codes that originate from the same code type and have identical or different data contents
•
The standard decoder is to read and distinguish bar codes with the same name (identical code type and data content)
The necessary calculations are provided in Chapter 10.8.1 Calculating the necessary capture area for the bar code if several bar codes are read on each object, Page 10-27. d) Parameterizing the output characteristics Result status: Switching outputs/"Read Result" LED: •
Define function of result status output of "Result 1" to "Result 4" switching outputs ("Read Result" LED): DEVICE CONFIGURATION tab Ö RESULT OUTPUT PARAMETERS button
Main data interface general: •
Destination result data strings Ö HOST INTERFACE tab Ö DESTINATION OF RESULT DATA STRINGS section
•
Filter reading result Ö DEVICE CONFIGURATION tab Ö ODETTE FILTER section
•
Sort reading result Ö DATA STRINGS tab Ö OUTPUT SEQUENCE SORT section
•
Mask reading result Ö DATA STRINGS tab Ö FORMAT MASK section
Host Interface:
6-12
•
Arrangement in data network Ö DEVICE CONFIGURATION tab Ö SCANNER ARRANGEMENT section
•
Physical interface Ö HOST INTERFACE tab Ö DATA FORMAT section
•
Communication parameters Ö HOST INTERFACE tab Ö DATA FORMAT section
•
Protocol Ö HOST INTERFACE tab Ö INTERFACE PROTOCOL section
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 71
Operating Instructions
Operation
Chapter 6
CLX490
Function of the CAN interface (alternative): See the operating instructions ”Using the CAN interface” (no. 8009180, English version) Data output string of host interface: •
Choose contents of "Header", "Code Info/Separator", "Splitter" and "Terminator" blocks Ö DATA STRINGS tab Ö OUTPUT FORMAT section
•
Position of "Code Info/Separator" blocks in data output string Ö DATA STRINGS tab Ö POSITION OF CODE INFO/SEPARATOR section
•
Set wrong read format Ö DATA STRINGS tab Ö READING DATA IN CASE OF ERROR section, CHARACTER COUNT section and ERROR STRING section
•
If necessary, parameterize/activate test string Ö DATA STRINGS tab Ö TEST STRING section
•
Parameterize special functions Ö DATA STRINGS tab Ö SPECIAL PARAMETERS button
•
Output external data string as reading result Ö DATA STRINGS tab Ö EXTERNAL DATA STRING PARAMETERS button e) Parameterizing the auxiliary interface (auxiliary interface) •
AUXILIARY INTERFACE tab f) Defining the start option for accessing the parameter set •
8009237/RB47/2007-08-03
On the DEVICE CONFIGURATION tab Ö choose START WITH ...
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-13
Page 72
Chapter 6
Operation
Operating Instructions CLX490 Compact OMNI Scanner
6.5
Operating modes and outputing the reading result
The following CLX operating modes/functions can be selected in CLV-Setup: Standard operating mode: •
Reading mode
For setup: •
Percentage evaluation
For adapting the device to the application at hand: •
Configuring (parameterizing ) the CLX See Chapter 6.4.1 Configuring the CLX with CLV-Setup, Page 6-4
•
Background teach-in
•
Background analysis
For monitoring purposes/troubleshooting: •
Display and edit operating data
•
Reading diagnosis
•
Monitor host interface
•
Auxiliary input
•
Self-test
6.5.1
Reading mode (standard operating mode)
The CLX performs a self-test after it has been switched on. It switches to Reading mode ("Device Ready" LED lights up). In the default setting the "Sensor" switching input is the (external) trigger source of the reading pulse. The reading result is output by the CLX at the end of the reading pulse via the host interface (default setting) and auxiliary interface. Depending of the configuration, the "Result 1" to "Result 4" switching outputs become live for the predefined pulse length when defined events occur during the reading process (e. g. Good Read). The reading result of the auxiliary interface can be displayed in the CLV-Setup Terminal Emulator. The CLX auxiliary interface must be set to the READING DIAGNOSIS mode for this purpose. This mode is selected for the default setting. The reading result of the auxiliary interface has a fixed, invariable format. The Reading mode can be called up by choosing VIEW in the menu bar or via the Terminal Emulator. Displaying the reading result in the Terminal Emulator:
6-14
1.
Click in the toolbar. The Terminal Emulator window is then displayed.
2.
In the DEVICE MODE section, choose READING MODE.
3.
Present the bar code pattern from Fig. 6-1 to the CLX and activate the reading pulse. The scan line must not hit any object in a distance closer to the CLX than the represented bar code (default setting: autofocus mode "Minimum distance"). The "Sensor" LED lights up and the red scan line appears. Also refer to Chapter 6.3.1 Switching the CLX on for the first time with the factory default settings, Page 6-3.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 73
Operation
Operating Instructions
Chapter 6
CLX490
4.
Ending the reading pulse. The CLX displays the reading result in the output window of the terminal emulator. The "Read Result" LED lights up for a duration of 100 ms (default setting).
Fig. 6-2, Page 6-15 shows two examples of the output of a reading result: Good Read and No Read. The reading result comprises the data contents of the bar code(s) and the reading diagnosis data. Fig. 6-3, Page 6-16 explains the structure and function of the reading diagnosis data for Good Read, and Fig. 6-4, Page 6-16 for No Read. Note
The CLX only outputs several bar codes in the reading result of the host interface if the parameterized minimum and maximum number of bar codes is > 1, and several bar codes have been presented to it. The number of bar codes to be read/output for each reading interval can be selected in the CODE CONFIGURATION tab in the NUMBER OF CODES section. The reading result of the host interface can also be displayed. Chapter 6.5.6 Monitor Host Interface, Page 6-22 describes the procedure for this and the structure of the reading result in the default setting.
Fig. 6-2:
8009237/RB47/2007-08-03
CLV-Setup: Displaying the reading result of the auxiliary interface in the Terminal Emulator
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-15
Page 74
Chapter 6
Operation
Operating Instructions CLX490 Compact OMNI Scanner
Good Read: TT=_ _200 ms MG=_25 % n=_1 AK=1 0123412345 C39 100% ST=0 CL=10 RA=_44 OD=_431 CS=_65 CA=_65 CK=_65 DI=X PO=·-_ 44 OW=+_ _0 FC=_334 ON=__0 With: 1st. line:
TT = MG = n = AK = 2nd. line: 0123412345= 3rd. line: C39 = 100% = ST = CL = RA = OD = CS = CA = CK = DI = 4th line
PO OW FC ON
Duration of the reading interval Temporal mean value of the identification quality Number of detected bar codes No. of the used distance configuration1) Data contents of the bar code ID: Code type Code 39 Identification quality Read status (ST = 0: Good Read) Code length (number of characters) Reading angle Object distance, radial measured (mm) Code reliability Scan effort Code continuity Decoding direction (F = in scanning direction, R = against scanning direction) Exact reading angle (3-digit, in °)(unit 0,1°) Exact oscillating angle (3-digit, in °)(unit 0,1°), not for CLX Current focus position (4-digit) in mm Consecutive object number
= = = =
1) not relevant for autofocus function
Fig. 6-3:
Reading result of the auxiliary interface: structure for "Good Read" No Read: TT=_ _ 260 ms MG=_56 % n=_0 AK=1 no code!
1st. line:
TT MG n AK 2nd. line: no code!
= = = = =
Duration of the reading interval Temporal mean value of the identification quality Number of codes detected No. of the distance configuration used1) No bar codes found!
1) not relevant for autofocus function
Fig. 6-4:
6-16
Reading result of the auxiliary interface: structure for "No Read"
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 75
Operation
Operating Instructions
Chapter 6
CLX490
Triggering the reading pulse via the Terminal Emulator In the default setting the "Sensor" switching input is the (external) trigger source of the reading pulse. The reading pulse can also be triggered directly via the Terminal Emulator of CLVSetup for test purposes. To do so, a different trigger source must be selected temporarily in the CLX. 1.
Choose DEVICE CONFIGURATION tab.
2.
In the READING TRIGGER MODE section click the SERIAL INTERFACE option.
3.
Perform a download to the CLX. To do so, click the SERIAL INTERFACE option again with the right mouse button and choose DOWNLOAD PARAMETER in the context menu. CLV-Setup copies the parameter to the CLX temporarily. The serial interface has been activated as the trigger source of the reading pulse and is ready to receive appropriate commands (until the CLX is switched off).
4.
Click in the toolbar. The Terminal Emulator window is then displayed. The CLX is in the Reading mode.
5.
Click the SW-TRIGGER ON button or press [F7]. CLV-Setup sends a start command to the CLX. The "Sensor" LED lights up and the red scan line appears as a cross.
6.
Present the bar code pattern from Fig. 6-1, Page 6-3 to the CLX.
7.
Click the SW-TRIGGER OFF button or press [F8]. CLV-Setup sends a stop command to the CLX. The "Sensor" LED is extinguished. The CLX switches off the laser diode. The CLX displays the reading result in the output window of the Terminal Emulator. The "Read Result" LED lights up for a duration of 100 ms (default setting).
6.5.2
Percentage evaluation
In the Percentage evaluation mode, the quality of the reading function is assessed (no conveyor movement). The CLX performs 100 scans in the free running mode and evaluates the reading quality. It outputs the reading result continuously every 2 s via the auxiliary interface. The reading results can be displayed in the terminal emulator of CLV-Setup. The standard decoder has to be set temporarily for the percentage evaluation. The "Result 1" to "Result 4" switching outputs do not become live in the Percentage evaluation mode. The Percentage evaluation mode can be called up by choosing VIEW in the menu bar, as a device function via CLX490 (interactively), or via the Terminal Emulator. Note
Autofocus mode: If the CLX operates with autofocus in stand-alone configuration, the Percentage evaluation mode can only be started in the Autofocus mode "Minimum distance" or "Differential background". The CLX fixes the timeout of the automatic focus position switchover to 30 ms, the preferred focus position is set to the last recognised object. If the CLX operates with autofocus in OTS mode ("Differential background and tracking"), the CLX switches automatically to the autofocus mode "Differential background“ during the the Percentage evaluation mode. The standard decoder has to be set temporarily for the percentage evaluation.
8009237/RB47/2007-08-03
1.
Choose the CODE CONFIGURATION tab.
2.
In the DECODER section, choose STANDARD.
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-17
Page 76
Operation
Chapter 6
Operating Instructions CLX490 Compact OMNI Scanner
3.
Perform a download to the CLX. To do so, click the STANDARD option again with the right mouse button and choose DOWNLOAD PARAMETER in the context menu. CLV-Setup copies the parameter to the CLX temporarily. The CLX then operates with the standard decoder (until the CLX is switched off).
4.
Click in the toolbar. The Terminal Emulator window is displayed. The CLX is in the Reading mode.
5.
In the DEVICE MODE section, choose PERCENTAGE EVALuation The dialog box for choosing the distance configuration is then displayed.
6.
Choose the appropriate distance configuration for the reading distance: – with autofocus mode the distance configuration no. 1 – with event-controlled focus control the distance configuration that corresponds to the reading distance of the object (default setting: no. 1, focus position F1 = 1,200 mm).
7.
Confirm the dialog box with OK. The ”Device Ready” LED is extinguished. The CLX initiates the percentage evaluation and outputs the reading results continuously. An example shows Fig. 6-5.
Fig. 6-5:
8. Note
CLV-Setup: Displaying the percentage evaluation in the Terminal Emulator
Present the bar code pattern from Fig. 6-1, Page 6-3 and monitor the reading results in the Terminal Emulator window.
In default setting, the CLX operates in the autofocus mode "Minimum distance“. As a result, the CLX focuses on the object that is nearest in Percentage Evaluation mode. The view on the object with the scan line must be unobstructed, i. e. any other objects must not protude into the autofocus space. If they do so, the autofocus mode "Differential background“ must be selected. Alternatively a fixed focus position can be set. The ”Read Result” LED also provides information on the reading quality:
6-18
–
The LED is extinguished if reading quality is < 30 %
–
The LED blinks twice per second if the reading quality is 30 % to 70 %
–
The LED blinks five times per second if the reading quality is 70 % to 90 %
–
The LED is lit continuously if the reading quality is > 90 %