Page 49
Operating Instructions
Electrical installation
Chapter 5
CLX490
Cable 1 ("Host/Term" connection) 15-pin D Sub HD socket in the connector cover and open cable end Pin
Signal
Wire color
1 1)
VS
Red and pink
2
RxD (RS 232), Auxiliary
White
3
TxD (RS 232), Auxiliary
Brown
4
Term (RS 422/485)
Violet
5
GND
Blue and grey-brown
6
RD+ (RS 422/485), Host
Green
7
RD– (RS 422/485), Host RxD (RS 232), Host
Yellow
8
TD+ (RS 422/485), Host
Grey
9
TD– (RS 422/485), Host TxD (RS 232), Host
Black
10
CAN H
Grey-pink
11
Reserved
Red-blue
12
CAN2 H
White-green
13
CAN2 L
Brown-green
14
Reserved
White-yellow
15
CAN L
Yellow-brown
–
Shield
Orange
1) Pin 1 is jumpered with Pin 1 of the" I/O" connection in the CLX
Table 5-12: Wire color assignment of cable 1 for external parameter memory no. 2020981
Cable 2 ("I/O" connection) 15-pin D Sub HD plug in the connector cover and open cable end Pin 1
1)
2
Signal
Wire color
VS
Red and pink
IN 1
White
3
Sensor
Brown
4
Result 1
Violet
5
GND
Blue and grey-brown
6
IN 0
Green
7
IN 2
Yellow
8
Result 2
Grey
9
INGND
Black
10
Result 3
Grey-pink
11
IN 3
Red-blue
12
IN 4
White-green
13
I2C SDA
–
14
I2C SCL
–
15
Result 4
Yellow-brown
–
Shield
Orange
1) Pin 1 is jumpered with Pin 1 of the "Host/Term" connection in the CLX
Table 5-13: Wire color assignment of cable 2 for external parameter memory no. 2020981
8009237/RB47/2007-08-03
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-11
Page 50
Chapter 5
Electrical installation
Operating Instructions CLX490 Compact OMNI Scanner c) Connections with connector cover no. 2021267 ¾
Cover the "Host/Term" and "I/O" connections on the CLX with the connector cover no. 2020267 and connect the free cable ends accordingly. The wire color assignments are shown in Table 5-14 and Table 5-15.
CLX with heater: The connector cover can be used with temperatures up to max. –50 °C if the CLX is stationary and the cables are not moved. If the cables are moved due to changes in the position of the CLX, the temperature must not drop below max. –40 °C. Cable 1 (power supply) 15-pin D Sub HD socket in the connector cover and open cable end Pin
Plug cover
Signal
Wire color
1
Socket
VS
Red
5
Socket
GND
Black
Table 5-14: Wire color assignment cable 1 for connector cover no. 2021267
Cable 2 (data and function interfaces) 15-pin D Sub HD socket/plug in the connector cover and open cable end Pin
Plug cover
Signal
Wire color
2
Plug
IN 1
White
3
Plug
Sensor
Brown
4
Plug
Result 1
Green
6
Plug
IN 0
Yellow
7
Plug
IN 2
Grey
8
Plug
Result 2
Pink
9
Plug
INGND
Blue
10
Plug
Result 3
Red
11
Plug
IN 3
Black
12
Plug
IN 4
Violet
15
Plug
Result 4
Grey-pink
2
Socket
RxD (RS 232), Auxiliary
Red-blue
3
Socket
TxD (RS 232), Auxiliary
White-green
4
Socket
Term (RS 422/485)
Brown-green
6
Socket
RD+ (RS 422/485), Host
White-yellow
7
Socket
RD– (RS 422/485), Host RxD (RS 232), Host
Yellow-brown
8
Socket
TD+ (RS 422/485), Host
White-grey
9
Socket
TD– (RS 422/485), Host TxD (RS 232), Host
Grey-brown
–
–
Shield
Orange
Table 5-15: Wire color assignment cable 2 for connector cover no. 2021267
5-12
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 51
Operating Instructions
Electrical installation
Chapter 5
CLX490
5.5
Electrical installation procedur
5.5.1
Individual steps
•
Connect the power supply
•
Connect the host interface
•
Connect the PC (connect the auxiliary interface)
•
Connect the "Sensor" and "IN 0 to IN 4" switching inputs
•
Connect the "Result 1 to Result 4" switching outputs
5.5.2
Tools
•
Tool
•
Digital measuring device (current/voltage measurement)
5.5.3
Connecting the supply voltage a) SICK AMV/S and BMV10 Connection Modules If the CLX is powered via the SICK Connection Modules, the supply voltage does not have to be wired separately. Connecting the CLX without external parameter memory: 1.
Make sure that the power supply to the Connection Module is switched off.
2.
Connect the "Host/Term" and "I/O" connections on the CLX to the corresponding connections on the Connection Module using two cables no. 2020302 and secure them tightly on both sides.
Connecting the CLX with external parameter memory: 1.
Mount the connector cover with the external parameter memory no. 2020307 on the "Host/Term" and "I/O" connections of the CLX and screw it tightly into position.
2.
Connect the two free plug connections on the cables to the corresponding connections on the Connection Module and secure them tightly.
The data and function interfaces of the CLX are connected to the Connection Module. b) Power supply via non-SICK Power pack Connecting the CLX without external parameter memory: 1.
Connect the cable socket on cable no. 2020303 on the "Host/Term" connection and screw it tightly into position.
2.
Connect the cable plug on the cable no. 2020264 to the "I/O" connection and screw it tightly into position.
3.
Connect the power supply to the red wire (Pin 1, VS) and blue wire (Pin 5, GND) on cable no. 2020303. See also Table 5-10, Page 5-9
Connecting the CLX with external parameter memory: 1.
Connect the "Host/Term" and "I/O" connections on the CLX to the corresponding connections on the Connection Module using two cables no. 2020981 and secure them tightly on both sides.
2.
Connect the power supply to the red/pink wire (Pin 1, VS) and the blue/grey-brown wire (Pin 5, GND) of cable 1. See also Table 5-12, Page 5-11.
The CLX is connected to the supply voltage.
8009237/RB47/2007-08-03
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-13
Page 52
Electrical installation
Chapter 5
Operating Instructions CLX490 Compact OMNI Scanner
5.5.4
Connecting the host interface AMV60-011/AMS60-012, -013 Terminal assignment
RS 232
( )=9-pin Sub D plug on PC
RS 422
CAN-Network: Connection diagram for SICK CAN Scanner Network see "CLV Connect" program on CD-ROM
Fig. 5-2:
Connecting the host interface
Risk of damage to the interface module! Electrical components in the CLX may be damaged if the host interface is connected incorrectly. This also applies when the host interface connections are changed in the Connection Modules (configuration).
Default
¾
Connect the host interface as shown in Fig. 5-2.
¾
Check the connections carefully before you switch on the CLX.
¾
Connect the host interface on the CLX to the host using shielded cables (EMC requirements). Ensure that the maximum cable lengths are not exceeded (see Table 5-7, Page 5-8).
In the default setting, the CLX communicates with the host via the host interface using the values shown in Table 5-16. Parameter
Value
Physical design
RS 422/485
Data transfer rate
9.600 bd
Data bits
8
Parity
None
Stop bits
1
Protocol
SICK (start character: STX, stop character: ETX, no request for repeat: none, timeout: 50 ms)
Table 5-16: Communication parameters for the host interface (default setting)
5-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 53
Electrical installation
Operating Instructions
Chapter 5
CLX490
For connecting the host interface via the AMV/S60 Connection Module, see the Operating Instructions for the "AMV/S60 Connection Module" (no. 8008296). Terminating the RS 422 interface The interface can be terminated in the Connection Module. See "Operating Instructions for the AMV/S60, AMV30-071, AMV100/200", or "BMS20 Connection Modules". Activating the RS 232 interface: The RS 232 interface can be activated with the CLV-Setup program:
Tip
1.
Choose the HOST INTERFACE tab.
2.
Choose the RS 232 option from the HARDWARE drop-down list under DATA FORMAT.
3.
Download the data to the CLX by clicking in the toolbar. The DOWNLOAD PARAMETERS dialog box is displayed.
4.
Confirm the dialog box by choosing PERMANENT. The CLX uses the RS 232 version of the host interface.
The communication parameters can be changed, if necessary, on the HOST INTERFACE tab. To do so, change the values under DATA FORMAT and INTERFACE PROTOCOL. 5.5.5
Connecting the CAN interface
For information on the connection and parameterization of the CLX for use in a SICK scanner network or in a CANopen network, see the Operating Instructions "Using the CAN interface" (no. 8009180, English version) 5.5.6
Connecting the PC
The CLX is operated and configured with the PC-based "CLV-Setup" program. In order to do so, you must connect the device to the PC via the auxiliary interface (auxiliary interface). Unlike the host interface, the auxiliary interface has a permanent data format and a fixed data transfer rate. Fig. 5-3 shows how the auxiliary interface is connected. The cable length should not be more than 10 m. AMV60-011/AMS60-012, -013 Terminal assignment or 9-pin "Service" plug
RS-232
( ) = 9-pin Sub D plug at PC Fig. 5-3:
Connecting the auxiliary interface
1.
Switch off the PC and power supply to the SICK Connection Module.
2.
Connect the PC to the internal, 9-pin "Aux" plug on the Connection Module. To do so, use a 3-core RS 232 data cable (null modem cable), e. g. no. 2014054 (RxD and TxD crossed). – or – Without the SICK Connection Module: Connect the PC as shown in Fig. 5-3.
8009237/RB47/2007-08-03
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-15
Page 54
Electrical installation
Chapter 5
Operating Instructions CLX490 Compact OMNI Scanner
3.
Switch on the PC and power supply to the SICK Connection Module.
4.
Set the communication parameters (see Chapter 10.6.3 Starting CLV-Setup, Page 10-18).
In the default configuration, the auxiliary interface outputs the reading result in reading diagnosis mode.
Tip
You can change the operating mode to MONITOR HOST INTERFACE, to MONITOR HOST INTERFACE 2 or AUXILARY INPUT on the AUXILARY INTERFACE tab in the "CLV-Setup" program. 5.5.7
Connecting the switching inputs
"Sensor" switching input If a reading procedure is to be triggered on the CLX by an external sensor, the reading pulse sensor must be connected to the "Sensor" switching input. This trigger type is selected in the default setting of the CLX. Fig. 5-4 shows the connections for the "Sensor" switching input. Table 5-17 contains the characteristic data for this input.
PNP sensor
VS
VS
1
2k6
3
VS
VS
OUT
Switch
AMV60-011/ AMS60-012, -013 Terminal assignment
1
VS / 24 V
T. 27
3
SENSOR
T. 19
9
(IN) GND
5
GND
Sensor IN GND
9
GND
5
CLX
GND
GND
T. 20 T. 36
VS= +18 to +30 V DC for CLX without heater, 24 V DC +20 % /–10 % for CLX with heater Fig. 5-4:
Connections of the "Sensor" switching input
¾
Connect the reading pulse sensor as shown in Fig. 5-4.
Switching mode
Current at the input starts the reading interval on the CLX. (default: active high, debouncing: max. 30 ms (standard))
Properties
– optodecoupled, non-interchangeable – can be connected to PNP output on a sensor
Electrical values
Low: –30 V ≤ Vin ≤ +2 V
High: +7 V ≤ Vin ≤ +13 V
Table 5-17: Characteristic data of the "Sensor" switching input
Tip
You can change the switching mode (polarity, debouncing, response for first pulse after power-up) of the "SENSOR" switching input on the DEVICE CONFIGURATION tab in the CLV-Setup program. ¾
Click the READING TRIGGER PARAMETERS button. Enter the values in the dialog box displayed.
For connecting the host interface via the AMV/S60 Connection Module, see the Operating Instructions for the "AMV/S60 Connection Module" (no. 8008296). Note
5-16
An external pulse is not required for Percentage Evaluation mode.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 55
Electrical installation
Operating Instructions
Chapter 5
CLX490
"IN 0 to IN 4" switching inputs If the Autofocus function is not used and the CLXs dynamic focus control function is to be triggered by external sensors, the sensors are connected to the five "IN 0 to IN 4" inputs. Together with the internal assignment table, these can be used to configure a maximum of 32 switching states for up to 8 distance configurations. The dynamic focus control function is selected for all inputs by default. Additional function IN 4: The "IN 4" input can alternatively be used as an input for a belt increment signal or for the reading pulse end. In this case, a maximum of 16 switching statuses can be used for dynamic focus control. Fig. 5-5 shows the connections for the "IN 0 to IN 4" switching inputs. Table 5-18 shows the pin assignment on the CLX and the terminal assignment in the AMV/S 60. Table 5-19, Page 5-18 contains the characteristic data for these inputs. Table 5-20, Page 5-18 shows the input combinations based on the distance configurations.
PNP sensor
VS
VS
1
VS
2k6
Y
OUT
VS
Switch
AMV60-011 AMS60-012, -013 Terminal assignment
1
VS / 24 V
T. 28
Y
IN X
Z
9
(IN) GND
5
GND
T. 20
IN X IN GND
9
GND
5
GND
CLX
GND
VS= +18 to +30 V DC for CLX without heater, 24 V DC +20 % /–10 % for CLX with heater Fig. 5-5:
T. 37
Pin and terminal assignment for IN X see Table 5-18
Connections of the "IN 0 to IN 4" switching inputs Input IN X
CLX "I/O" connection Pin Y
AMV/S60 Terminal Z
N0
Pin 6
T. 22
N1
Pin 2
T. 23
N2
Pin 7
T. 24
N3
Pin 11
T. 25
N4
Pin 12
T. 26
Table 5-18: Pin and terminal assignment for "IN 0 to IN 4" switching inputs
¾
Connect the sensors as shown in Fig. 5-5.
For connecting the host interface via the AMV/S60 Connection Module, see the Operating Instructions for the "AMV/S60 Connection Module" (no. 8008296).
8009237/RB47/2007-08-03
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-17
Page 56
Chapter 5
Electrical installation
Operating Instructions CLX490 Compact OMNI Scanner
Function
Switching mode Properties Electrical values
Trigger source for dynamic focus control "IN 4" alternative: – belt increment input – Reading puls end (Active High) – Reading puls end (Active Low) Default setting "IN 4": dynamic focus control Active when input energized (high) – Optodecoupled, non-interchangeable – Can be connected to PNP output on a sensor Low: –30 V ≤ VI ≤ +2 V
High: +7 V ≤ VI ≤ +13 V
Table 5-19: Characteristic data of the "IN 0 to N 4" switching inputs
Switching inputs 1)
Logic state "IN 4 to IN 0" inputs 00000 00001 00010 00011 00100 00101 00110 00111 01000 01001 01010 01011 01100 01101 01110 01111 10000 10001 10010 10011 10100 10101 10110 10111 11000 11001 11010 11011 11100 11101 11110 11111
Assignment table index
Content Assignment Table– Distance Config.2) Default setting Example: Photoelectric switches (bright switching)
N1 N2 N3 N4 N5 N6 N7 N8 N9 N 10 N 11 N 12 N 13 N 14 N 15 N 16 N 17 N 18 N 19 N 20 N 21 N 22 N 23 N 24 N 25 N 26 N 27 N 28 N 29 N 30 N 31 N 32
DC 1 DC 2 DC 3 DC 4 DC 5 DC 6 DC 7 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8 DC 8
DC 6 DC 5 DC 4 DC 4 DC 3 DC 3 DC 3 DC 3 DC 2 DC 2 DC 2 DC 2 DC 2 DC 2 DC 2 DC 2 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1 DC 1
1) 1 = energized (active); 0 = deenergized (inactive) 2) Distance configuration (DC): data record for focus position
Table 5-20: Dynamic focus control: switching inputs/distance configuration assignment table
5-18
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 57
Electrical installation
Operating Instructions
Chapter 5
CLX490
Parameter settings of switching inputs "IN 3"
Effects
"IN 4"
Focus control
Focus control1)
"IN 3" switches the focus position in combination with "IN 0" to "IN 2" and "IN 4"
Focus control1)
Increment counter
"IN 4" receives increment signals "IN 3" switches the focus position in combination with "IN 0" to "IN 2"
Focus control1)
End of reading interval
"IN 4" triggers the end of reading interval "IN 3" switches the focus position in combination with "IN 0" to "IN 2"
1)
1) depending on the assignment table
Table 5-21: Combination of the functions of the "IN 0" to "IN 4" switching inputs
Tip
The function assigned to the "IN 4" input can be modified on the DEVICE CONFIGURATION tab in the CLV-Setup program. ¾
Click the FUNCTION IN 4 drop-down list and choose the required function. Perform a download to the CLX.
5.5.8
Connecting the "Result 1 to Result 2" switching outputs
The four switching outputs can be assigned different functions for outputting result statuses independently of each other. If the assigned event occurs during the reading procedure, the corresponding switching output becomes live at the end of the reading pulse for the selected pulse duration. The pulse duration can be set individually for each output. The "Read Result" LED is linked to the "Result 2" output and lights up in Reading mode for the selected pulse duration and function of the result status display (default: Good Read, 100 ms). Fig. 5-6 shows the connections for the "Result 1 to Result 4" switching outputs. Table 5-22 shows the pin assignment on the CLX and the terminal assignment in the AMV/S 60. Table 5-23, Page 5-20 contains the characteristic data for these outputs. The four outputs have the same characteristic data.
AMV60-011/ AMS60-012, -013 Terminal assignment
Fuse
VS
Logic
Result X Y Temperature sensor
GND
5
VS= +18 to +30 V DC for CLX without heater, 24 V DC +20 %/–10 % for CLX with heater Fig. 5-6:
RL
Result X
Z
GND
T. 35
Pulse duration depending on setting: – 10 ms to 900 ms – 100 ms to 9,900 ms – 00: static (to the end of next reading pulse)
Pin and terminal assignment for Result X see Table 5-22
Connections of the "Result 1 to Result 4" switching outputs
8009237/RB47/2007-08-03
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-19
Page 58
Electrical installation
Chapter 5
Operating Instructions CLX490 Compact OMNI Scanner
Output Result X
CLX "I/O" connection Pin Y
AMV/S60 Terminal Z
Result 1
Pin 4
T. 31
Result 2
Pin 8
T. 32
Result 3
Pin 10
T. 33
Result 4
Pin 15
T. 34
Table 5-22: Pin and terminal assignment for "Result 1 to Result 4" switching outputs
¾
Connect the outputs as shown in Fig. 5-6.
Switching mode
PNP-switching with respect to the supply voltage VS
Properties
The current in the event of a short-circuit is limited to 0.7 A
Function assignment (default)
Result 1: Device Ready (static), polarity: not inverted Result 2: Good Read (100 ms), polarity: not inverted Result 3: No Read (100 ms), polarity: not inverted Result 4: Match 1 (100 ms), polarity: not inverted
Electrical values
0 V ≤ Voutr ≤ 30 V Iout ≤ 100 mA
Guaranteed: Vout ≤ VS –1.3 V with Iout ≤ 100 mA
Table 5-23: Characteristic data of the "Result 1 to Result 4" switching outputs
Note
If the "Device Ready" function is chosen, the CLX outputs a static pulse in Reading mode. For connecting the host interface via the AMV/S60 Connection Module, see the Operating Instructions for the "AMV/S60 Connection Module" (no. 8008296).
Tip
Recommondation
5-20
The output function, pulse duration (timer), and polarity of the signals can be changed on the DEVICE CONFIGURATION tab in the "CLV-Setup" program. ¾
Click the RESULT OUTPUT PARAMETERS button and enter the values in the dialog box displayed. Perform a download to the CLX.
¾
To check the switching functions using a high-impedance digital voltmeter, connect a load to the outputs to prevent incorrect voltage values/switching statuses from being displayed.
© SICK AG · Division Auto Ident · Germany · All rights reserved