Page 103
Operating Instructions
Technical data
Chapter 9
CLX490
9
Technical data 9.1
Data sheet CLX490-0010 Compact OMNI Scanner
Type
CLX490-0010
Laser diode (wave length)
Red light (λ = 650 nm)
MTBF of laser diode
20,000 h
Laser class
Class 2 pursuant to EN/IEC 60825-1 (for publication date, see the warning sign on the device), shutoff of laser diode after 10 min1)
Focus Control
Autofocus, alternatively event-controlled focus control
No. of distance configurations (DC)
Max. 8
Focus adjustment time
≤ 20 ms (typically)
Focus trigger source
"IN 0 to IN 4" switching inputs/data interface/timer
Scanning/decoding frequency
600 to 1,200 Hz
Resolution (typically)
0.30 to 1.0 mm
Reading ranges
Fig. 10-1, Page 10-2
Bar code print contrast (PCS)
≥ 60 %
Ambient light compatibility
2,000 lx (on bar code)
No. of bar codes per scan
1 to 12 (standard decoder), 1 to 5 (SMART decoder)
No. of bar codes per reading interval
2)
1 to 50 (autodiscriminating)
Bar code types
Code 39, Code 128, Code 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved
Bar code length
Max. 50 characters (max. 600 characters across all bar codes per reading interval)
Print ratio
2:1 to 3:1
No. of multiple reads
1 to 99
Optical indicators
4 x LEDs
Reading pulse
"Sensor" switching input (Option: additionally "IN 4")/Free-running/Serial interface/ Object Polling/OTS
"Host" data interface
RS 232 or RS 422/485, variable data output format
Data transmission rate
300 to 57,600 bd
Protocols
SICK Standard and 3964(R)
Physical configurations
Stand-alone
"CAN" data interface
20 kbit/s to 1 Mbit/s, CANopen protocol, CAN Scanner Network
"Auxiliary" data interface
RS 232, 9,600 bd, 8 data bits, no parity, 1 stop bit, fixed output format
Functional switching inputs
6 ( Sensor, "IN 0 to IN 4") – optodecoupled, Vimax = +30 V, non-interchangeable, can be connected to PNP outputs – "Sensor" (reading pulse): max. internal delay 30 ms, reduced max. 2 to 6 ms – "IN 0 to IN 4": focus position switching, IN 4: selectable function, max. internal delay 30 ms
Functional switching outputs
4 ("Result 1" to "Result 4") – PNP, short-circuit-proof, variable pulse duration (static; 10 to 990 ms or 100 to 9,900 ms) – Variable output function for result status
Electrical connections
1 x 15-pin D Sub HD plug, 1 x 15-pin D Sub HD socket
Operating voltage/power consumption
18 to 30 V DC/ typically 11 W, max. 16 W SELV respectively PELV pursuant to IEC 60364-4-41 (2005)
Housing
Aluminium die-cast, does not represent a problem in paint shops
Electrical safety
Pursuant to EN 61010-1 (2001-03)
Protection class
III, pursuant to EN 61140 (2002-03)
1) Default setting, in Reading mode with the Switching input sensor and Serial interface pulse types. 2) Reading interval: time window generated internally for evaluating the code.
Table 9-1: Technical specifications of the CLX490-0010
8009237/RB47/2007-08-03
© SICK AG · Division Auto Ident · Germany · All rights reserved
9-1
Page 104
Technical data
Chapter 9
Operating Instructions CLX490 Compact OMNI Scanner
Type
CLX490-0010
Enclosure rating
IP 653) pursuant to EN 60529 (1991-10); A1: (2002-02)
EMC tested
Pursuant to EN 61000-6-2 (2001-10), EN 61000-6-3 (2001-10), EN 61000-6-3/A11 (2004-07)
Vibration/shock tested
Pursuant to EN 60068-2-6 (1995) test FC/to EN 60068-2-27 (1993) test EA
Weight
Approx. 2 kg
Ambient operating/storage temperature
0 to +40 °C/–20 to +70 °C
Max. rel. humidity
90 %, non condensing
Color
SICK blue (RAL 5012)
3) With plug cover or plug cover with parameter memory
Table 9-1: Technical specifications of the CLX490-0010 (contd.)
9.2
Data sheet CLX490-0011 Compact OMNI Scanner
Technical data as CLX490-0010 with the following exceptions: Type
CLX490-0011
Design
With heater
Switching on function/temperature graph
See Chapter 10.4 Optional heating, Page 10-12
Power-on delay
35 to 40 min (at 24 V DC and min. ambient operating temperature –30 °C)
Operating voltage
24 V DC +20 %/–10 %, SELV respectively PELV pursuant to IEC 60364-4-41 (2005)
Power consumption
Typically 75 W, max 90 W
Required cross-section
Min. 0.5 mm2 (for power supply)
Weight
Approx. 2 kg
Ambient operating/storage temperature
–30 to +35 °C/–20 to +70 °C
Table 9-2: Technical specifications of the CLX490-0011
9.3
Dimensioned drawing of the CLX
CLX490-0010 CLX490-0011 175.5
114.7
152.6
208
Drilled hole, M6, 7 mm deep Blind hole thread, ∅ 3.6 mm, 6 mm deep 33 .5
10
.2 43
9-2
10
21
Fig. 9-1:
56
78 3 11
114 142
.5 0 38 1 12
All dimensions in mm
Dimensions of the CLX
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 105
Appendix
Operating Instructions
Chapter 10
CLX490
10
Appendix 10.1
Overview
The appendix contains the following additional information: •
Specification diagrams
•
Installation and operating instructions for the external parameter memory
•
Optional heating (temperature graph/ switching on function)
•
System messages
•
Installation and operating instructions for the PC-based "CLV-Setup" program
•
Configuring a CLX using command strings
•
Parameter value calculations for configuring the CLX
•
Tables
•
Special applications and procedures
•
Instructions for replacing a CLX (copying the parameter set)
•
Ordering Information
•
Dimensioned drawings of the accessories
•
Supplementary documentation
•
Glossary
•
Copy of the EC-Declaration of Conformity
•
Index
•
Scannable sample bar codes
10.2
Specification diagrams
10.2.1
Reading conditions for all diagrams
Test code
Code 128
Print ratio
> 90 %
Tilt
±45°
Ambient light
< 2,000 lx
Good Read rate
> 75 %
Table 10-1: Reading conditions for specification diagrams
Note
8009237/RB47/2007-08-03
The min. and max. reading distances are measured radially by the CLX.
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-1
Page 106
Fig. 10-1:
10-2
© SICK AG · Division Auto Ident · Germany · All rights reserved
-250
-200
-150
-100
-50
0
50
100
500
600
700
800
900
1000
1100 1200
1300 1400
Appendix
Reading distance (mm)
1500 1600 1700 1800 1900
Reading conditions: see Table 10-1, Page 10-1
Characteristics field scanning frequency as a function of reading distance and resolution: see Fig. 10-2, Page 10-3
0.50 mm
0.35 mm
0.30 mm
Resolution:
10.2.2
150
200
250
Reading field height (mm)
CLX490-0010/-0011
Chapter 10 Operating Instructions
CLX490 Compact OMNI Scanner
Reading performance data CLX490 Compact OMNI Scanner
Diagram: Reading field (reading limits)
8009237/RB47/2007-08-03
Page 107
Appendix
Operating Instructions
Chapter 10
CLX490
CLX490-0010/-0011 Scanning frequency (Hz) 1300 1200 1100 1000 900 800 700 600 500
700
900
1100
1300
1500
1700
1900
Reading distance (mm) Resolution: 0.35 mm 0.50 mm
Fig. 10-2:
Reading conditions: see Table 10-1, Page 10-1
Scanning frequency as a function of the reading distance and resolution
8009237/RB47/2007-08-03
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-3
Page 108
Chapter 10
Appendix
Operating Instructions CLX490 Compact OMNI Scanner
10.2.3
Fig. 10-3:
10-4
Reading field and system dimensions
Required mounting position of the CLX above the conveyor belt (resolution 0.30 mm, conveyor belt width 300 mm)
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 109
Operating Instructions
Appendix
Chapter 10
CLX490
Fig. 10-4:
Required mounting position of the CLX above the conveyor belt (resolution 0.35 mm, conveyor belt width 400 mm)
8009237/RB47/2007-08-03
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-5
Page 110
Chapter 10
Appendix
Operating Instructions CLX490 Compact OMNI Scanner
Fig. 10-5:
10-6
Required mounting position of the CLX above the conveyor belt (resolution 0.50 mm, conveyer belt width 400 mm)
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 111
Appendix
Operating Instructions
Chapter 10
CLX490
Modul width (mm)
Vertical focus position (mm)
Fig. 10-6:
0.35 mm
1000 1100 1200 1300 1400 1500
0.5 mm
1000 1100 1200 1300 1400 1500 1600
Reading distance (mm) 900
1000
1100
1200
1300
1400
1500
1600
1700
1800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
Depth of field as a function of module width and focus position at a belt width of 400 mm
8009237/RB47/2007-08-03
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-7
Page 112
Chapter 10
Appendix
Operating Instructions CLX490 Compact OMNI Scanner
10.3
Installing and operating the external parameter memory
The external parameter memory is available as an accessory. It is located in a connector cover and comprises a permanent, rewriteable memory (EEPROM) with 4 kByte from CLX firmware V 2.0. The connector cover covers the two connections of the CLX in the enclosure rating IP 65. The cover is shown in Fig. 10-7. Two connection cables that are secured by means of conduit thread connections supply the signals to the CLX.
22 (0.86) 88.5 (3.48) 22 (0.86)
27 (1.06) 50 (1.79)
Fig. 10-7:
27 (1.06)
External parameter memory, installed on the CLX
The external parameter memory is available in different implementations: Order no.
Two Connection cables with
CLX
Length Connection
2020307
Two 15-pin D Sub HD plug connections, (pin assignment identical to device connections)
Without heater
3m
CLX to AMV/S60 AMV30-071 and BMV10
2020981
Two open cable ends
Without heater
3m
CLX to non-SICK Power pack, free wiring
2021689
Two 15-pin D Sub HD plug connections, (pin assignment identical to device connections)
With heater
3m
CLX to AMV100/200
Table 10-2: External parameter memory variants
10.3.1
Function
When it is started, the CLX is initialized with he data stored in its internal parameter set. If this parameter set has been copied to an external memory, the device can be replaced easily. The replacement device, therefore, does not have to be configured manually. Instead, it accesses the external parameter memory automatically (assuming that the correct start option has been selected). It then imports the parameter set to its RAM. This option is set by default. The "Device Ready" and "Read Result" LEDs indicate whether the external memory was accessed successfully. The CLX also outputs plain-text messages for troubleshooting purposes on the auxiliary interface.
10-8
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03