Page 13

Operating Instructions

Notes on this document

Chapter 1

CLX490

1

Notes on this document 1.1

Purpose

This document is a guide to the operation of the CLX490 Compact OMNI Scanner with autofocus in the following variations: – CLX490-0010, resolution from 0.30 mm – CLX490-0011, resolution from 0.30 mm, with heater This document provides information on •

Mounting and connecting the device

•

Startup

•

Operating and configuring (parametrizing) the device

•

Maintenance

•

Exchanging the device without losing the parameter set

•

Special applications and procedures

The CLX490 Compact OMNI Scanner with all its variants will in this manual be referred to as the "CLX", except where a distinction is necessary.

1.2

Target audience

This document is intended for persons who are responsible for the following activities: 1.2.1

Mounting, electrical installation, maintenance and replacement

Electricians and service technicians. 1.2.2

Startup, operation and configuration

Technicians and engineers.

1.3

Information content

This document contains all the information required to mount, install, and start up the CLX with the factory default settings. A series of step-by-step instructions is provided for each of these activities. Configuration of the CLX for the application-specific reading situations is carried out with the Windows-based PC software "CLV-Setup". Further assistance is also available in the form of the online help system CLV-Setup Help. The procedure for installing and operating the software is described in the appendix. For further information on the design of the bar code scanner or on bar code technology in general, please contact the Division Auto Ident at SICK AG. Internet address: www.sick.com.

8009237/RB47/2007-08-03

© SICK AG · Division Auto Ident · Germany · All rights reserved

1-1

Page 14

Notes on this document

Chapter 1

Operating Instructions CLX490 Compact OMNI Scanner

1.4

Symbols

Some of the information in this document is marked specially so that you can access it quickly: Warning! Warnings are provided to prevent injury to operating personal or serious damage to the bar code scanners. ¾

Reference Note Explanation Recommendation Tip Default SCANNING FREQUENCY

Always read warnings carefully and observe them at all times.

Italics are used to refer to more detailed information elsewhere. Indicates special features or characteristics. Explanations provide background information on technical features. Recommendations help you carry out certain procedures more effectively. Tips explain settings in the user interface of the "CLV-Setup" program. Marks a section containing the factory defaults. This typeface is used to refer to a term in the "CLV-Setup" program. Icons refer to buttons in the "CLV-Setup" program.

"Host receive fault"

This typeface is used for messages output via the auxiliary interface of the CLX. This symbol is used to mark sections that describe steps carried out with the "CLV-Setup" program.

This symbol refers to additional technical documentation.

1-2

¾

There is a procedure which needs to be carried out. This symbol indicates operational instructions which only contain one operational step or operational steps in warning notices which do not have to be followed in any particular order. Operational instructions comprising several steps are denoted using consecutive numbers.

Ö

Here you select a function of the "CLV-Setup" user interface.

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03

Page 15

Safety information

Operating Instructions

Chapter 2

CLX490

2

Safety information 2.1

Authorized users

For the CLX to function correctly and safely, it must be mounted and operated by sufficiently qualified personnel. Repairs to the CLX should only be carried out by qualified and authorized SICK AG service staff. The end user must be supplied with the operating instructions. The end user must be provided with expert tuition and is advised to read the operating instructions. The following qualifications are required for the various tasks involved: 2.1.1

Mounting and maintenance

•

General technical training

•

Knowledge of the standard guidelines relating to safety at the workplace

2.1.2

Electrical installation and replacement

•

Practical training in electrical engineering

•

Knowledge of the standard safety guidelines relating to electrical engineering

•

Experience operating the devices in the relevant application (e. g. conveyor belt)

2.1.3

Startup, operation and configuration

•

Experience operating the devices in the relevant application (e. g. conveyor belt)

•

Knowledge of the hardware and software environment of the relevant application (e. g. conveyor belt)

•

Basic understanding of Windows 95TM/98TM, Windows NT4.0TM, Windows 2000TM or Windows XPTM

•

Ability to use an HTML browser (e. g. Internet ExplorerTM)

•

Basic understanding of data transfer methods

•

Basic understanding of bar code technology

2.2

Intended use

The CLX is designed to detect and decode bar codes automatically. It is mounted in a reading station and reads bar codes on objects positioned on a conveyor belt, for example. The CLX transfers the data content of the decoded bar codes via its host interface to a host for further processing. As an option, the CLX can be used with other devices, e. g. CLV490, in an OMNI Portal System. Note

8009237/RB47/2007-08-03

Any warranty claims against SICK AG shall be deemed invalid in the case of other system use or system modifications, this includes modifications during installation and electrical installation, changes to the SICK software, or opening the device.

© SICK AG · Division Auto Ident · Germany · All rights reserved

2-1

Page 16

Safety information

Chapter 2

Operating Instructions CLX490 Compact OMNI Scanner

2.3 ¾

General safety instructions and protection measures Always read the general safety instructions carefully and observe them at all times. Please also observe the warnings in front of the operating instructions in each chapter of this document.

Shock hazard! Depending on the type of device, the AMS60 Connection Module (accessory) for the CLX is connected to a mains voltage of 230 V AC 50 Hz or 115 V AC 50 to 60 Hz. ¾

When working with electrical equipment, always follow the relevant safety specifications.

Laser beam can cause blindness! The CLX uses a class 2 red-light laser. Looking directly at the laser beam can seriously damage your eyesight. The entire glass window acts as a laser outlet aperture. Caution – use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. ¾

As with sunlight, never look directly into the laser beam.

¾

Do not direct the laser beam at the eyes of other persons.

¾

Mount and align the CLX490 in such a way to prevent the laser beam reflecting off mirrored surfaces.

¾

Do not open the housing. (Opening the housing does not deactivate the laser diode).

¾

Observe the laser protection specifications (latest version).

Laser power The laser operates at a wave length of λ = 650 nm (visible red light). The power output at the reading window is max. 2.8 mW. The emitted radiation is not dangerous to human skin. The product is classified in laser class 2 (laser class II) in accordance with EN 60825-1, IEC 60825-1, and 21 CFR 1040.10 (for publication date, see the warning sign on the device). Note

No maintenance required to keep this product in compliance with laser class II. Laser warnings The laser warning symbols (Fig. 2-1) can be found on the CLX at the following locations: The laser warning symbol is positioned on the reading window. The GB/US laser warning is located on the side containing the electrical connections (see Fig. 3-1, Page 3-3.)

2-2

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03

Page 17

Safety information

Operating Instructions

Chapter 2

CLX490 black-yellow signed on device:

black-silver signed on device:

Fig. 2-1:

Note

Laser warning labels on the CLX

A set of laser warnings in German/US English and French/US English is included in the delivery scope. The GB English/US English warnings can be pasted over with these if necessary. If the CLX is installed in a machine/panel with the result that the laser warning labels are no longer visible, additional warnings in the same language (not included in the scope of delivery) must be provided on the machine beside the emergence aperture of the laser beam. Internal protective circuits The CLX is equipped with monitoring circuits that deactivate the laser diode in the event of a malfunction. Activation and deactivation of the laser diode is controlled by the reading pulse trigger. A timer (laser timeout) automatically deactivates the laser diode in Reading mode ("Sensor input" and "Serial interface" trigger mode) if the reading interval has not ended after 10 minutes (default setting). However, it does not end the reading interval. In this case, the CLX outputs the message "Laser safety timeout" on the auxiliary interface. The reading interval must be terminated by resetting the trigger signal. The laser diode is activated again by the next reading trigger. The laser timeout can be set in the range of 1 min to 25 h or deactivated (see Table 6-7, Page 6-11). In the "Percentage Evaluation" mode as well as in the pulse mode "Free-running", in reading mode, the laser diode is constantly activated. In the pulse mode "Object Polling" the laser diode is activated due to the parameterized search/pause ratio.

Note

8009237/RB47/2007-08-03

In Reading mode, the CLX carries out a measurement referencing at regular intervals. During referencing, it turns the laser diode on for a maximum of 10 seconds.

© SICK AG · Division Auto Ident · Germany · All rights reserved

2-3

Page 18

Chapter 2

Safety information

Operating Instructions CLX490 Compact OMNI Scanner

2.4

Quick stop and quick restart

2.4.1

Stopping the CLX

¾

Switch off the power supply or remove the cables of the CLX from the connection module.

This can result in loss of the following (at the most): •

The application-specific parameter set, if it was stored temporarily in the CLX

•

The last reading result

•

Daily operating data (operating hours counter, number of reading intervals, Good Read count, No Read count, maximum duration trigger, minimum duration trigger, matchcode 1 count, matchcode 2 count, no match count)

2.4.2 ¾

Restarting the CLX

Switch on the power supply or reattach the cables of the CLX490 to the connection module. The CLX resumes operation with the parameter set that was last stored permanently and reset the daily operating data.

2.5

Environmental information

The CLX is designed to cause minimum impact on the environment. It does not contain any silicone-based materials on the housing surface and, therefore, does not represent any problems for paint sprayers in paint shops, for example. 2.5.1

Power requirements

The power requirements depend on the variants: •

The CLX490 Compact OMNI Scanner has a typical power consumption of 11 W and max. 16 W

•

The CLX490 Compact OMNI Scanner equipped with an integrated heater has a typical power consumption of 75 W and max. 90 W

The values are given for devices with disconnected switching outputs. 2.5.2

Disposal after removal from service

Always dispose irreparable devices in a manner that is not harmful to the environment and in accordance with the applicable national waste disposal regulations. The CLX can be separated into recyclable secondary raw materials and special-category waste (electronic scrap). See also Chapter 7.4 Disposal, Page 7-3. SICK AG currently does not accept delivery of unusable or irreparable devices.