The text of a manual · part 4 of 18
Operating Instructions CLX490 Compact OMNI Scanner for Bar Codes: 3 Product description
Pages 19 to 28 of 158, from Operating Instructions CLX490 Compact OMNI Scanner for Bar Codes
The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick CLX490
Page 19
Product description
Operating Instructions
Chapter 3
CLX490
3
Product description 3.1
Design
3.1.1
Scope of delivery
The CLX is supplied with the following in the packing: • an information sheet (notes on device) with terminal diagram and Quick Start instructions
• an additional set of Class 2 laser warning labels (self-adhesive) in German/US English and French/US English
•
CD-ROM (no. 2029112) with – "CLV-Setup" program for WindowsTM and the "CLV-Setup Help" online help system (HTML files) – "CLV Connect" PC software (HTML files showing terminal diagrams) – CLX490 Operating Instructions in English and German as PDF edition as well as additional publications (connections module, other SICK bar code scanners) – freely available "Acrobat Reader" PC software for reading PDF files
Note
The latest versions of all the current publications/programs on the CD-ROM can also be downloaded from www.sick.com. Depending on the number of copies ordered, the delivery includes (optional): •
CLX490 Operating Instructions in English and/or German (printed edition)
Chapter 10.12 Ordering information, Page 10-35 contains an overview of the available accessories, connection modules, cables, and connectors, as well as sensors for generating the reading pulse. 3.1.2
Variants
The CLX is currently available in the following variants: Type (red light)
Part. no.
Scanning method
Resolution
Heater
CLX490-0010
1019318
CLX490 Compact OMNI Scanner from 0.30 mm no
CLX490-0011
1019319
CLX490 Compact OMNI Scanner from 0.30 mm yes
Tab. 3-1: CLX variants
3.1.3 CLX without heater
System requirements
The following are required to start up and operate the CLX without heater: 1.
A SICK Connection Module to provide the power supply and connect the data and function interfaces. Available types: – For connecting one CLX: AMV60-011 (no. 1017134) for 18 to 30 V DC, enclosure rating max. IP 54 AMS60-013 (no. 1017139) for 230 V AC 50 Hz/24 V DC, enclosure rating max. IP 54 AMS60-012 (no. 1017140) for 115 V AC 50/60 Hz/24 V DC, enclosure rating max. IP 54 AMV100-011 (no. 6021105) for 18 to 30 V DC, enclosure rating max. IP 65
8009237/RB47/2007-08-03
© SICK AG · Division Auto Ident · Germany · All rights reserved
3-1
Page 20
Product description
Chapter 3
Operating Instructions CLX490 Compact OMNI Scanner
– For connecting two CLX: AMV30-071 (no. 1017391) for 18 to 30 V DC, enclosure rating max. IP 54 AMV200-011 (no. 6021106) for 18 to 30 V DC, enclosure rating max. IP 65 – or – Alternatively, a non-SICK Power pack with a voltage output of 18 to 30 V DC (functional extra-low voltage pursuant to IEC 364-4-41) and a minimum power output of 20 W. Cable no. 2020264 (3 m) with 15-pin D Sub HD connector and one open end for connecting the CLX to the non-SICK Power pack (supply voltage). 2.
The following operating voltages/power output values: – AMV60-011: 18 to 30 V DC (to IEC 364-4-41), min. 20 W – AMV30-071: 18 to 30 V DC (to IEC 364-4-41), min. 40 W – AMV100-011: 18 to 30 V DC (to IEC 364-4-41), min. 20 W – AMV200-011: 18 to 30 V DC (to IEC 364-4-41), min. 40 W – AMS60-013: 230 V AC ±10 % 50 Hz – AMS60-012: 115 V AC ±10 % 50 to 60 Hz
3.
Fitting cables see Chapter 5.2.2 Prefabricated cables (overview), Page 5-2.
4.
Appropriate incremental transmitter for tracking.
5.
With external clock pulse supply via the "Sensor" switching input: a suitable reading pulse sensor for signaling an object with a bar code, e.g. a photoelectric reflex switch.
6.
With object distance detection via the "IN 0 to IN 4" switching inputs: suitable sensors for multi-stage dynamic focus control, e. g. photoelectric reflex switches.
7.
A higher-level computer (host) with a data interface of type RS 422/485 or RS 232.
8.
A PC (min. Pentium II, 350 MHz, 64 MB RAM, CD drive, a serial port (COM x), mouse (recommended)) with Windows 95TM/98TM, Windows NTTM, Windows 2000TM or Windows XPTM.
9.
A 3-core RS 232 data cable (null modem cable) with two 9-pin D Sub sockets for connecting the PC to the auxiliary interface of the CLX in the connection module, e. g. no. 2014054. Pin 2 (RxD) and Pin 3 (TxD) are crossed.
10. An HTML browser, e. g. Internet ExplorerTM, for using the online help system CLV-Setup Help. 11. The appropriate bus connection module BMV/BMH10 (available on request) for connecting the CLX to the Interbus-S, Profibus DP, Device Net or the Ethernet. 12. For connection of the CLX to the CAN bus: the operating instructions "Using the CAN interface" (no. 8009180, English version) CLX with heater
The following are required to start up and operate the CLX with heater: 1.
A SICK Connection Module from the AMV100 or AMV200 series to provide the power supply and connect the data and function interfaces. Available types: – For connecting one CLX: AMV100-011 (no. 6021105) for 24 V DC, max. IP 65 – For connecting two CLXs: AMV200-011 (no. 6021106) for 24 V DC, max. IP 65 – or – Alternatively, a non-SICK Power pack with a voltage output of 24 V DC +20 %/–10 % (functional extra-low voltage pursuant to IEC 364-4-41) and a minimum power output of 100 W. Cable no. 2020264 (3 m) with 15-pin D Sub HD connector and one open end for connecting the CLX to the non-SICK Power pack (supply voltage).
3-2
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 21
Operating Instructions
Product description
Chapter 3
CLX490
2.
The following operating voltages/power output values: – AMV100-011: 24 V DC +20 %/–10 % (pursuant to IEC 364-4-41), min. 100 W – AMV200-011: 24 V DC +20 %/–10 % (pursuant to IEC 364-4-41), min. 200 W
3.
See pos. 3 under CLX without heater
3.1.4
Design
➊ ➋ ➌
➒
➋ ➑ ➍ ➐ ➎ ➏
Legend ➊ Reading window
➍ Blind hole thread M6, 7 mm deep,
➋ Laser warning label ➌ Mark for counting direction for the reading angle
➐ "Host/Term" connector for securing the device
➎ Drilled hole, Ø 3.6 mm, 6 mm deep
➏ Blind hole thread M4, 10 mm deep,
15-pin D Sub HD plug
➑ "I/O" connector, 15-pin D Sub HD socket
➒ LED (status indicators)
for the connector cover Fig. 3-1:
Design of the CLX
8009237/RB47/2007-08-03
© SICK AG · Division Auto Ident · Germany · All rights reserved
3-3
Page 22
Chapter 3
Product description
Operating Instructions CLX490 Compact OMNI Scanner
3.2
Method of operation
The CLX first scans the bar code with a folded scan line (resulting in a cross) and then decodes it. The data is forwarded via the main data interface (serial host interface) to a host/ PC for further processing. An overview of the CLX functions is provided in Fig. 3-2. CLX490 PC Operation Parameterization, etc.
Scanner Decoder
Photoelectric switch Reading pulse
Signal1) Focal control Conveyer increment
Interface "Host" "IN 0" "IN 1"
"Result 1"
"IN 2"
"Result 2"
"IN 3"
"Result 3"
"IN 4"
"Result 4"
1) if requered
Fig. 3-2:
"Terminal"
"Sensor"
HOST Further processing of the reading result Status display e. g. Device Ready e. g. Good Read e. g. No Read e. g. Match 1
VS
Block diagram: CLX functions
The CLX is equipped with two decoders: •
The SMART decoder (SICK Modular Advanced Recognition Technology) for decoding bar codes with small code height, bar codes that are dirty or damaged, as well as bar codes that are tilted excessively (azimuth angle)
•
The tried-and-tested standard decoder of the CLV series
The CLX derives useful diagnosis data from the reading process and can transfer it also to the host. It also records operating data that can be interrogated at any time. The quality of the read can be checked in percentage evaluation mode. To start the reading process when an object is located in the reading field, the CLX requires a suitable trigger. This opens an internal time window ("reading interval") in the CLX. In the default configuration, this trigger is supplied by an external reading pulse sensor. Alternative trigger sources include free-running mode or a command via the host interface (for more complex applications: OTC trigger). With small object distances (object distance < reading gate length) the bar code has to be allocated to the right object with the help of the internal tracking of the CLX. The current operating status is indicated by four LEDs. If the trigger is supplied externally, the "Sensor" switching input instructs the CLX to start the reading process. The five "IN 0 to IN 4" switching inputs switch the focus position in response to certain events, as an alternative to the autofocus function. The "IN 4” input can also be assigned to special functions. The four "Result 1 to Result 4" switching outputs can be assigned to different functions alternativly for displaying the result status and also control external devices, such as a PLC. The CLX is operated and configured via the auxiliary interface (serial auxiliary interface) using the CLV-Setup software or via the host interface/auxiliary interface using command strings. System, warning, and error messages help you configure the device and locate the source of errors during startup and reading mode.
3-4
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 23
Operating Instructions
Product description
Chapter 3
CLX490
3.2.1
Autofocus function
The autofocus function enables the CLX to detect the distance of an object without the need for external sensors, and then adjust the focus position automatically. In order to do so, the CLX measures the object distance in its reading field in front of the reading window and internally creates a distance profile. Following this, it positions the focus on the object. 3 operating modes are provided for various applications: •
Minimum distance: the CLX focuses on the minimum distance in the distance profile and ignores the background in the reading field. Application: with unobstructed view of the object without any surrounding objects protruding into the reading plane. One object with bar code(s) only is inside the reading field during one reading pulse.
•
Differential background: the distance profile of the reading field background is programmed (teach-in) in the CLX without any objects present. The CLX focuses on the object which it recognizes by comparing the object with the background. Application: with unobstructed view of the object restricted by other objects that protrude into the reading plane. One object with barcode(s) only is inside the reading field during one reading pulse.
•
Differential background and tracking: if several objects with different distances are positioned in the reading field at the same time (distance conflict), the CLX focuses on the object that is nearest to but has not exceed its internal focus switchover point. Application: in OTS operation (applications with tracking by the OMNI Tracking Controller OTC 400), or stand alone in internal tracking mode.
The distance profile of the background can also be displayed in the "CLV-Setup" program. The reading field is defined by the autofocus range. The park setting of the focus position, from which the device focuses for each read, can be specified in addition to a time and/or position-related delay (timeout or hysteresis). If necessary, an offset can be defined for the focus position to be set by the measurement. The depth of field, which radiates in the direction of the scan line and is caused by the V-principle of the beam deflection, is optimized as a result (Fig. 3-3).
Measured distance Optimum focus position: measured distance plus offset for maximum Depth of field (DOF)
Fig. 3-3:
8009237/RB47/2007-08-03
Optimization the depth of field for the object
© SICK AG · Division Auto Ident · Germany · All rights reserved
3-5
Page 24
Chapter 3
Product description
Operating Instructions CLX490 Compact OMNI Scanner
3.2.2
Event-controlled dynamic focus control
As an alternative to the autofocus function, the CLX can switch its focus position in response to certain events and thus dynamically cover a large reading range. A maximum of eight reading ranges can be defined as distance configurations for this purpose and approached consecutively in reading mode (see Fig. 3-4). Reading field height 1
2
3
4
5
6
7
8
Focus position
Reading distance DC 8 DC 6
Focus position
DC 7
DC 5 DC 4 DC 3 DC 2 DC 1 Reading distance DC = Distance Configuration
Fig. 3-4:
Dynamic focus control: classification of the reading range in distance configurations
The switch over takes place in response to changes in the object distance (with reads from above: object height detection). The trigger source for the switchover is a signal combination at the "IN 0 to IN 4" switching inputs, a command on the host interface/auxiliary interface or the integrated timer (e. g. for search mode). The distance configurations are assigned to the swichover sequence by means of a programmable assignment table. The object distance measurement of the autofocus function can additionally be used to define the distance configurations. 3.2.3
Additional components
Heater The CLX can be permanently equipped with a heater for applications involving temperatures up to max. –30 °C (e. g. in a freezer). The design, technical data, and power-up behavior of the CLX are described in Chapter 10.4 Optional heating, Page 10-12. External parameter memory The external parameter memory is located in a connector cover which, when mounted, covers the two electrical terminals on the CLX (IP 65). The parameter memory saves you time when a CLX is replaced locally by providing a copy of the current parameter set. In other words, you do not have to configure the new device. For information on applications and operating procedures, see Chapter 10.3 Installing and operating the external parameter memory, Page 10-8.
3-6
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 25
Operating Instructions
Product description
Chapter 3
CLX490
3.3
Indicators and control elements
3.3.1
Control elements
The CLX is operated and configured via the auxiliary interface using the CLV-Setup program or using command strings sent via the host interface/auxiliary interface. A variety of parameter options allow you to adapt the device to a wide range of applications. The following can be defined: •
The configuration of the code types
•
The read, evaluation, and output properties
•
The communication parameters of the host interface
•
The structure of the data output string for Good Read and No Read on the host interface
•
The function of the auxiliary interface
Chapter 10.6 Installing and operating the "CLV-Setup" program, Page 10-15 describes the procedure for installing the "CLV-Setup" program and explains how to use it. The parametrization (configuration) procedure is explained in Chapter 6.4 Configuring (parameterization) the CLX, Page 6-4. 3.3.2
Function of the LEDs
Four LEDs indicate the operating status, activity of the laser diode, reading result status, and data transfer on the host interface. The LEDs are located on the rear of the device (Fig. 3-5). If the optional external parameter memory is connected, the LEDs also indicate whether the memory was successfully accessed.
Device Ready Sensor Read Result Data
Fig. 3-5:
LEDs
The meaning of the LEDs in the various operating modes/functions is shown in Table 3-2, Page 3-8 and Table 3-3, Page 3-9.
8009237/RB47/2007-08-03
© SICK AG · Division Auto Ident · Germany · All rights reserved
3-7
Page 26
Product description
Chapter 3
Operating Instructions CLX490 Compact OMNI Scanner
CLX without external parameter memory Operating mode LED Start
Display
Device Ready Green
Function • Lights up after power-up if the self-test was successful Subsequent behavior depends on selected start option
Start option: START WITH EXTERNAL PARAMETERS (DEFAULT) • Lights up constantly (CLX has loaded internal parameter set) Start option: START WITH INTERNAL PARAMETERS: • Lights up constantly (CLX has loaded internal parameter set) Start option: START WITH COPY INTERN -> EXTERN: • Blinks constantly together with the "Read Result" LED1) (CLX has loaded internal parameter set) Read Result
Green
Start option: START WITH COPY INTERN -> EXTERN: • Blinks constantly together with the "Device Ready" LED1)
Device Ready Green
• Lights up constantly • Extinguishes with new operating mode/function
Sensor
Green
• Lights up if reading diode is active (The laser diode is activated/deactivated by reading pulse) • Lights up constantly in Free-running mode, since laser diode is always active
Read Result
Green
LED is linked to the "Result 2" switching output and indicates the selected result status for the defined pulse duration of the output. • Lights up after a successful read (default: Good Read) • Lights up if the match code comparison is active, the bar code read matches the specified match code(s) and the corresponding result status output is selected for the "Result 2" output
Data
Yellow
• Flickers when the CLX transfers data to the host on the host interface
Percentage
Sensor
Green
• Lights up constantly, as Free-running mode is active evaluation
Read Result
Green
Behavior depends on the reading quality: • Extinguishes if reading rate < 30 % • Blinks twice a second if reading rate 30 % to 70 % • Blinks five times a second if reading rate 70 % to 90 % • Lights up constantly if reading rate > 90 %
Reading mode
1) Set the start option to START WITH THE INTERNAL PARAMETERS on the DEVICE CONFIGURATION tab in the "CLV-Setup" program. Download to CLX!
Table 3-2: Meaning of LEDs: CLX without external parameter memory
3-8
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03
Page 27
Operating Instructions
Product description
Chapter 3
CLX490
CLX with external parameter memory connected Operating mode LED Start
Display
Device Ready Green
Function • Lights up after power-up if the self-test was successful Subsequent behavior depends on selected start option: Start option: START WITH EXTERNAL PARAMETERS (default): • Blinks for approx. 10 s before lighting up constantly (CLX has loaded the parameter set from the external parameter memory and starts reading mode straight away) • Blinks for approx. 10 s together with the "Read Result" LED, then lights up constantly. (CLX has loaded the parameter set from the external parameter memory with tolerated errors1) and starts reading mode straight away) • Lights up constantly (CLX could not find an external parameter memory and loads the internal parameter set instead) • Blinks constantly together with the "Read Result" LED2) (The external parameter memory contains the parameter set for another CLX type, or is corrupt.) CLX has loaded the internal parameter set. It starts Reading mode but does not output data over the host interface) Start option: START WITH INTERNAL PARAMETERS: • Lights up constantly (CLX has loaded internal parameter set) Start option: START WITH COPY INTERN -> EXTERN: • Blinks alternately with the "Read Result" LED for approx. 10 s before lighting up constantly (CLX has successfully copied the internal parameter set to the external memory and has reset the start option to START WITH EXTERNAL PARAMETERS) CLX has loaded the internal parameter set. • Blinks constantly together with the "Read Result" LED2) (The external parameter memory is either not connected or corrupt, or the parameter set is too large to be copied). CLX has loaded the internal parameter set.
Read Result
Green
Start option: START WITH EXTERNAL PARAMETERS (Default): • Blinks for approx. 10 s together with "Device Ready" LED1) (see above) or • Blinks constantly together with the "Device Ready" LED2) (see above) Start option: START WITH COPY INTERN -> EXTERN: • Blinks alternately with "Device Ready" LED for approx. 10 s (see above) or • Blinks constantly together with the "Device Ready" LED2) (see above)
Reading mode
Device Ready Green
• Lights up constantly • Extinguishes with new operating mode/function
Sensor
Green
• Lights up if reading diode active. (The laser diode is activated/deactivated by the reading pulse) • Lights up constantly in Free-running mode, since the laser diode is constantly active
Read Result
Green
LED is linked to the "Result 2" output and indicates the selected result status for the defined pulse duration of the output. • Lights up after a successful read (default: Good Read) • Lights up if the match code comparison is active, the bar code read matches the specified match code(s) and the corresponding result output is selected for the "Result 2" output
1) We recommend that you check the parameter set manually, e. g. by printing out the entire configuration. For troubleshooting, see also Chapter 8.3.2 LED error messages for the external parameter memory, Page 8-3 2) Stops blinking when you switch from Reading mode to Parameterization mode
Table 3-3: Meaning of LEDs: CLX with external parameter memory
8009237/RB47/2007-08-03
© SICK AG · Division Auto Ident · Germany · All rights reserved
3-9
Page 28
Product description
Chapter 3
Operating Instructions CLX490 Compact OMNI Scanner
Operating mode LED
Display
Function
Reading mode
Data
Yellow
• Flickers when the CLX transmits data to the host over the host interface
Percentage
Sensor
Green
• Lights up constantly, since Free-running mode is active evaluation
Read Result
Green
Behavior dependent on the reading quality: • Extinguishes if reading rate < 30 % • Blinks twice a second if reading rate 30 % to 70 % • Blinks five times a second if reading rate 70 % to 90 % • Lights up constantly if reading rate > 90 %
(contd.)
Table 3-3: Meaning of LEDs: CLX with external parameter memory (contd.)
3-10
© SICK AG · Division Auto Ident · Germany · All rights reserved
8009237/RB47/2007-08-03