Page 29

Installation

Operating Instructions

Chapter 4

CLX490

4

Installation 4.1

Note

Installation sequence

•

Change the language version of the laser warning label (if necessary)

•

Select the mounting location for the CLX

•

Align the CLX with the bar code and mount the CLX

•

Mount the AMV/S60 Connection Module

•

Connect the CLX to the AMV/S60 Connection Module

•

Adjust the CLX so that it is in line with the bar code

•

Mount the reading pulse sensor for external triggering the reading pulse

•

Optionally: Mount incremental transmitter (for the internal tracking mode)

•

Option with event-controlled dynamic focus control: mount the sensors for detecting the object distance

Don’t open the device. The warranty will be forfeited if the device is opened.

4.2

Preparations

4.2.1

Required components

•

CLX490 Compact OMNI Scanner

4.2.2 •

Required accessories

SICK mounting bracket for the CLX: depending on the order, angle bracket no. 2022996, or quick-clamping device no. 2016110 with securing material for the CLX

– or – Alternatively, if the bracket is supplied by the user: – Stable mounting device that allows the alignment of the CLX to be varied in the x and y axes. The weight of the CLX is approx. 2 kg. – 2 screws M6 for the CLX. The screw length depends on the wall thickness of the bracket used. Depth of engagement in CLX max. 7 mm from housing surface. •

AMV/S60 Connection Module (not included in the scope of supply of the CLX)

•

Reading pulse sensor for external reading pulse triggering, e. g. photoelectric reflex switch/ photoelectric proximity switch (not included in the scope of supply of the CLX)

•

Option with event-controlled dynamic focus control: sensors for detecting the object distance, e. g. photoelectric reflex switches/photoelectric proximity switches (not included in the scope of supply of the CLX)

4.2.3

8009237/RB47/2007-08-03

Required auxiliary parts

•

2 screws M6 for securing the SICK mounting bracket to the base. The screw length depends on the wall thickness of the base.

•

Set of laser warning labels (if necessary)

•

Tool

•

Measuring tape (up to 2,000 mm)

•

Protractor

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-1

Page 30

Chapter 4

Installation

Operating Instructions CLX490 Compact OMNI Scanner

4.2.4

Replacing the laser warning label

If necessary, replace the GB English/US English laser warning label with the required language (Fig. 4-1). The device is delivered with a set of laser warnings in: •

German/US English laser warning and

•

French/US English laser warning

See also Chapter 2.3 General safety instructions and protection measures, Page 2-2. Supplied laser warnings:

Fig. 4-1:

Replacing the laser warning labels

4.2.5

Selecting the mounting location

When you select the mounting location, the distance between the CLX and the host and between the CLX and the bar code are important. Distance between the CLX and the host The CLX can be mounted at a maximum distance of 1,200 m from the host without a connection to the SICK network or a bus. In practice, however, the distance depends on the physical configuration of the host interface and the data transfer rate (see Table 5-7, Page 5-8). Distance between the CLX and the AMV/S60 Connection Module The AMV/S60 Connection Module should not be located further than 10 m from the CLX, since the "CLV-Setup" program on the PC accesses the auxiliary interface (RS 232) of the CLX via this module.

4-2

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03

Page 31

Operating Instructions

Installation

Chapter 4

CLX490

4.2.6

Mounting accessories

The CLX is secured in position using the two tapped blind holes (M6) above the electrial connections. Fig. 4-2 shows the location of the threads near the CLX. The dimensions of the CLX housing are shown in Fig. 9-1, Page 9-2.

114.7

175.5

Drilled hole, ∅ 3.6, 6 mm deep Blind hole thread, M6, 7 mm deep 33 .5

10

.2 43 56

78 3 11

8.5

3

10 10

21 12

Fig. 4-2:

Position of the securing threads on the CLX

The CLX can be mounted using the SICK bracket: •

Angle bracket no 2022996.

•

Quick-clamping device no. 2016110

The brackets are designed to support the mounting of the CLX to horizontal and vertical surface. Fig. 4-3 shows two mounting examples for angle bracket no. 2022996.

Fig. 4-3:

Mounting possibilities of the CLX with angle bracket no. 2022996

The dimensions of the angle bracket is shown in Chapter 10.13 Dimensioned drawings of the accessories, Page 10-39.

8009237/RB47/2007-08-03

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-3

Page 32

Chapter 4

Installation

Operating Instructions CLX490 Compact OMNI Scanner

4.2.7

Distance between the CLX and the object

Basic alignment between the CLX and bar code The CLX is used for reading omnidirectionally oriented bar codes on the lateral or upper sides of objects. Fig. 4-4 shows the basic alignment of the CLX. Reading distance to the object The distance between the reading window of the CLX and the object must not exceed the technical limits. The height of the reading field is shown as a function of the reading distance for various resolutions (module widths) in Chapter 10.2.2 Reading performance data CLX490 Compact OMNI Scanner, Page 10-2. Fig. 4-4 shows the definition of the reading distance "a" (radial measured) from the reading window.

Reading distance a

Fig. 4-4:

Definition of the reading distance a to bar code and convoyer direction

Due to the X-principle of beam deflection, the reading field height (for evaluating the useful length of the scan line) depends on the readling distance. Angular alignment of the CLX All possible reading angles that can occur between the scan line and the bar code must be taken into consideration (Fig. 4-5 and Table 4-1). α :Azimuth angle (tilt) β: Angle of inclination (pitch) γ: Angle of rotation (skew)

Reading range

Object distance Fig. 4-5:

Reading angles between the scan line and the bar code

Angle

Limit value

Tilt α (azimuth)

Omnidirectional

Pitch β

Max. 45°

Skew γ

Max. 45°

Table 4-1: Permissible reading angles between the scan lines and bar code

4-4

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03

Page 33

Installation

Operating Instructions

Chapter 4

CLX490

Note

If reading from the front, mount the CLX above the conveyor belt in such a way against the conveying direction that the scan line hits the object under a skew of approx. 10°. 4.2.8

Explanation

Count direction of the reading angle RA

The CLX can scan and decode several bar codes with each read. In doing so, it determines the specific local reading diagnosis data for each bar code the reading angle (RA value) of the center of the bar code within the scan. Fig. 4-6 shows the count direction of the reading angle. The count direction of the reading angle is marked by a cross in the reading window. By determining this data, the device can separate identical bar codes.

Fig. 4-6:

Tip

100

0

50

51

100

0

Count direction of the reading angle RA in the scan line

In the default setting, the CLX does not output the "RA" value in the reading result on the host interface. If this is required to evaluate the result in the host, the values can be included in the "Code-Info/Separator" block of the output string using the "CLV-Setup" program. Configuring the Code-Info/Separator:

8009237/RB47/2007-08-03

1.

Choose the DATA STRINGS tab.

2.

Click the CODE-INFO/SEPARATOR field. The EDIT PARAMETER TFS dialog box is displayed.

3.

In the list field, click the RA parameter. RA then appears in the top line.

4.

Confirm your selections with OK.

5.

Download the data to the CLX by clicking in the toolbar. The DOWNLOAD PARAMETERS dialog box is then displayed.

6.

The CLX490 outputs the RA value on the host interface for each bar code in the reading result. The values are displayed as a 3-digit number in the associated "Code-Info/Separator" block.

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-5

Page 34

Installation

Chapter 4

Operating Instructions CLX490 Compact OMNI Scanner

4.3

Mounting and adjusting the device

4.3.1

Mounting the CLX

1.

Prepare the base for mounting the bracket as described in Chapter 4.2.2 Required accessories, Page 4-1.

2.

Place the object containing the bar code within the reading field of the CLX (in the position at which it is to be read) with the conveyor belt switched off.

3.

Allign the CLX reading window in parallel to bar code surface. Consider the positioning of the CLX in relation to the conveyor direction (see Fig. 4-4, Page 4-4). All of the possible reading angles must be taken into consideration (see Fig. 4-5, Page 4-4).

4.

If it is relevant for the evaluation, note the count direction of the reading angle (see Fig. 4-6, Page 4-5).

5.

Mount the CLX bracket on the base.

Risk of damage to the device! The maximum depth of engagement of the two blind hole threads M6 is 7 mm. Longer screws will damage the device. ¾

Use screws with the correct length.

6.

Screw the screws M6 through the bracket into the blind hole threads of the CLX.

7.

Tighten the screws slightly.

8.

Adjust the CLX as described below.

4.3.2

Adjusting the CLX

The CLX can be adjusted in Percentage Evaluation mode. In this mode, the CLX displays the quality of the bar code reads that enter the CLX reading field statically (the object is not moved on the conveyor belt). In the Free-running mode the CLX performs 100 scans and evaluates the reading quality statistically. It then outputs the reading results every 2 s on the auxiliary interface. Note

In default setting, the CLX operates in the autofocus mode "Minimum distance“. As a result, the CLX focuses on the object that is nearest in Percentage Evaluation mode. The view on the object with the scan line must be unobstructed, i. e. any other objects must not protude into the autofocus space. If they do so, the autofocus mode "Differential background“ must be selected. Alternatively a fixed focus position can be set. The behavior of the "Read Result" LED also indicates the reading quality. –

The LED is extinguished if reading quality is < 30 %

–

The LED flashes twice per second if the reading quality is 30 % to 70 %

–

The LED flashes five times per second if the reading quality is 70 % to 90 %

–

The LED is lit continuously if the reading quality is > 90 %

The scanning frequency in the default setting is 800 Hz. 1.

4-6

Connect the CLX to the AMV/S60 Connection Module and switch on the power supply (see Chapter 5.5.3 Connecting the supply voltage, Page 5-13). After it has started, the CLX confirms that the self-test was successfuly and switches to reading mode ("Device Ready" LED lights up).

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03

Page 35

Operating Instructions

Installation

Chapter 4

CLX490

2.

Connect the PC to the auxiliary interface of CLX. To do so, connect a 3-core RS 232 data cable (null modem cable) to the internal 9-pin "Service" plug of the AMV/S60 (see Chapter 5.5.6 Connecting the PC, Page 5-15).

3.

Start Windows and the "CLV-Setup" program (see Chapter 10.6.3 Starting CLV-Setup, Page 10-18).

Choosing the standard decoder: 4.

Choose the CODE CONFIGURATION tab.

5.

Click the STANDARD option in the DECODER section.

6.

Download the settings to the CLX. To do so, click the STANDARD option again with the right mouse button and choose DOWNLOAD PARAMETER in the context menu. CLV-Setup copies the parameter to the CLX temporarily. The CLX then operates with the standard decoder (until the CLX is switched off).

Activating Percentage Evaluation mode: 7.

From the VIEW menu, choose PERCENTAGE EVALUATION. The dialog box for entering the distance configuration appears.

8.

Click the relevant distance configuration for the reading distance: – with autofocus mode the distance configuration no. 1 – with event-controlled dynamic focus control the distance configuration that matches the reading distance of the object (default: no. 1, focus position F = 1,200 mm).

9.

Confirm the dialog box with OK. The Terminal Emulator is launched and displays the reading result continuously (see Chapter 6.5.2 Percentage evaluation, Page 6-17). Monitor the reading quality (%) during each of the subsequent steps!

Fine adjustment: 10. Align the CLX in such a way that the angle between the scan line and the bars on the bar code CLX is almost 90°. 11. To avoid interfering reflections, align the CLX reading window in parallel to the bar code surface. Consider the positioning of the CLX in relation to the convoyer direction (see Fig. 4-4, Page 4-4). 12. If necessary, align the intersecting point of folded scanline exactly with the bar code. 13. Move objects carrying bar codes into the CLX reading field manually under realistic conditions and check the reading result. If the objects are aligned randomly, or if the bar code is located at different positions (angles), ensure that the limit values of the permissible reading angles are not exceeded. 14. Adjust the CLX in such a way that the good read rate is between 70 to 100 %. With event-controlled dynamic focus control, for each defined reading range (distance configuration), check the selected focus position and correct the parameter settings if necessary (see Chapter 6.4.3 Guide to parameterization menu, Page 6-8). 15. Tighten the screws on the CLX. The CLX is aligned with the bar code.

8009237/RB47/2007-08-03

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-7

Page 36

Installation

Chapter 4

Operating Instructions CLX490 Compact OMNI Scanner

4.4

Mounting the external components

4.4.1

Mounting the AMV/S60 Connection Module

1.

Mount the AMV/S60 Connection Module near the CLX. The distance between the AMV/S60 and CLX should not exceed max. 10 m.

2.

Mount the AMV/S60 in such a way that accessed to the open device is always possible. The auxiliary interface of the CLX is accessed via the internal "Service" plug.

Detailed information on the mounting and electrical installation procedures is provided in the Operating Instructions for the "AMV/S60 Connection Module" (order no. 8008296). 4.4.2

Mounting the external reading pulse sensor

If the CLX is triggered by an external reading pulse sensor, the sensor must be mounted in the vicinity of the CLX. The "Sensor" switching input is selected as the default trigger source for this trigger type. The default debounce time of the input is 30 ms. Depending on the application, you may need to mount the sensor in such a way that bar codes on objects of different sizes can be read completely during the reading interval. The exact position fo the external sensor in relation to the scanner can be seen in Fig. 10-3 to Fig. 10-5 onwards page 10-4. Note

4-8

In default setting, the CLX operates in the autofocus mode "Minimum distance“. As a result, the CLX focuses on the object that is nearest. The view on the object with the scan line must be unobstructed, i. e. any other objects must not protude into the autofocus space. If they do so, the autofocus mode "Differential background“ must be selected. Alternatively a fixed focus position can be set. 1.

Mount the reading pulse sensor.

2.

Connect the reading pulse sensor to the "Sensor" switching input of the CLX via the AMV/S60 Connection Module (see Chapter 5.5.7 Connecting the switching inputs, Page 5-16).

3.

Connect the CLX to the AMV/S60 Connection Module and switch on the power supply to the module (see Chapter 5.5.3 Connecting the supply voltage, Page 5-13). After it has started, the CLX confirms that the self-test was successfull and switches to Reading mode ("Device Ready" LED lights up).

4.

Connect the PC to the auxiliary interface of CLX. To do so, connect a 3-core RS 232 data cable (null modem cable) to the internal 9-pin "Service" plug of the AMV/S60 (see Chapter 5.5.6 Connecting the PC, Page 5-15).

5.

Start Windows and the "CLV-Setup" program (see Chapter 10.6.3 Starting CLV-Setup, Page 10-18).

6.

From the VIEW menu, choose READING MODE. The Terminal Emulator is launched. The CLX is in Reading mode (default: SMART/ Standard Decoder). Monitor the reading result during each of the subsequent steps!

7.

Move objects with bar codes into the CLX reading field manually under realistic conditions and check whether the reading result and trigger pulse are correct.

8.

Repeat the procedure with the conveyor switched on. Check whether the reading procedure is synchronized with the objects.

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03

Page 37

Operating Instructions

Installation

Chapter 4

CLX490

Parameterizing an external sensor as a trigger source: These settings are not required if the CLX is operated with the default configuration. 1.

Choose the DEVICE CONFIGURATION tab.

2.

In the section READING TRIGGER SOURCE click the option SENSOR INPUT (ACTIV HIGH).

3.

Download the settings to the CLX by clicking in the toolbar. The DOWNLOAD PARAMETERS dialog box is then displayed.

4.

Confirm the dialog box by choosing PERMANENT. The CLX operates with the "Sensor" switching input as an external trigger source. The reading pulse starts when the input is energized (high).

4.4.3

Mounting the sensors for detecting the object distance

If the dynamic focus control function of the CLX is triggered by external sensors, suitable sensors must be mounted in the vicinity of the CLX. Fig. 4-7 shows an example of a read operation from above. The sensors must be arranged in such a way that all of the potential object heights are classified uniquely and overlapping reading ranges occur that can be formed with the depths of field of the CLX. A maximum of five switching inputs are available for this purpose. A max. of 32 switching states for 8 distance configurations (reading ranges) can be implemented using the internal assignment table (combinations). Photoelectric reflex switches, for example, can be used to detect the object distance. In the default setting, all five "IN 0 to IN 4" switching inputs are selected for dynamic focus control.

;

Object distance

DC 8

LS7 h7

Reading distance

DC 2

LS2

DC 1 h2 h1

LS1

DC = Distance Configuration

Fig. 4-7:

8009237/RB47/2007-08-03

Mounting example for object distance detection

1.

The depths of field of the CLX for the bar code resolution in question is shown in the graph in Chapter 10.2.2 Reading performance data CLX490 Compact OMNI Scanner, Page 10-2. Find and note suitable focus positions for overlapping reading ranges.

2.

Mount distance sensors (e. g. photoelectric reflex switches) one above the other in a row at the mounting location to measure the object distance (see also assignment Table 5-20, Page 5-18). It is advisable to mount these distance sensors opposite the direction of motion of the conveyor belt at approx. 100 mm in front of the reading pulse sensor.

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-9

Page 38

Installation

Chapter 4

Operating Instructions CLX490 Compact OMNI Scanner

3.

Connect the distance sensors to the "IN 0 to IN 4" switching inputs on the CLX via the AMV/S60 Connection Module (see Chapter 5.5.7 Connecting the switching inputs, Page 5-16).

4.

Set the focus positions for the required reading ranges on the READING CONFIGURATION tab in the CLV-Setup program. To do so, choose the INPUTS/SERIAL option in the drop down list of the FOCUS CONTROL section.

5.

Click the DISTANCE CONFIGURATION button and edit the required entries in the dialog box that is then displayed (default: Focus position F 1 up to F 8 = 1,200 mm).

6.

As described in Chapter 4.3.2 Adjusting the CLX, Page 4-6, choose the standard decoder.

7.

Perform a temporarily download to the CLX.

8.

Start Percentage Evaluation mode

9.

Check the reading quality in all distance configurations while the conveyor bel stationary.

10. Then check the distance detection function in Reading mode under realistic conditions. To do so, monitor the reading result in the Terminal Emulator as described in Chapter 4.4.2 Mounting the external reading pulse sensor, Page 4-8. 11. If the distance detection function operates correctly, reset the decoder to the SMART/ STANDARD option and perform a permanently download to the CLX. Note

The CLX can switch between a maximum of 8 distance ranges for slow search runs using the integrated timer reversal points. The CLX can be switched between a maximum of 8 distance ranges synchronously to the reading process using command strings.

4.5

Dismantling the device

1.

Switch off the power supply to the AMV/S60 Connection Module.

2.

Undo the screws for the cable connections on the CLX and disconnect the cables. With mounted external parameter memory (in connector cover)(optional): Undo both screws and remove the cover.

3.

Unscrew the CLX from the mounting device.

When removing the device from service for the last time, please dispose of it in an environmentally-friendly manner, as described in Chapter 7.4 Disposal, Page 7-3.

4-10