Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 16 of 18

Operating Instructions CLX490 Compact OMNI Scanner for Bar Codes, pages 133 to 142

Pages 133 to 142 of 158

The original document is the PDF (3.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick CLX490

Page 133

Operating Instructions

Appendix

Chapter 10

CLX490

10.10 Special applications and procedures 10.10.1 Auxiliary input via auxiliary interface If the CLX cannot read a bar code in Reading mode (e. g. if there is no bar code on the object), the data content of the bar code can be sent subsequently to the host by using the "Auxiliary input" function. In this way, the sequence of reading results can be completed if necessary. The auxiliary input function uses the auxiliary interface of the CLX exclusively and features two options: • manual entry of the data content on the keyboard of a connected terminal or PC (Terminal Emulation function)

• entry of the bar code using a hand-held reader. The data is then forwarded to the CLX via an internal or external decoder

Fig. 10-15 shows the basic auxiliary input principle.

Data contents + Status ST = 7

Data contents

Fig. 10-15: Auxiliary input via the auxiliary interface of the CLX

The CLX sends the data content of the bar code that it receives via the auxiliary interface to the host in the same format as the other reading results on the host interface. Each string can contain the data from a bar code with a maximum length of 50 characters. The CLX automatically enters the status ST = 7 if the error status has been enabled for transmission. The values of the other reading diagnosis data in the data string do not have any significance. To enable the CLX to receive the data content of the bar code on the auxiliary interface, you must switch the operating mode on the interface to auxiliary input . 1.

Connect the PC to the auxiliary interface on the CLX using a 3-core RS 232 data cable (null modem cable) (AMV/S60: connect the PC to the internal 9-pin "Service" plug). See Chapter 5.5.6 Connecting the PC, Page 5-15.

2.

Start CLV-Setup on your PC. See Chapter 10.6.3 Starting CLV-Setup, Page 10-18.

3.

Choose the AUXILIARY INTERFACE tab.

4.

Choose the AUXILIARY INPUT option from the drop-down list.

5.

Download the changes to the CLX. To do so, click the AUXILIARY INPUT option again with the right mouse button and choose DOWNLOAD PARAMETER in the context menu. CLV-Setup copies the parameter to the CLV temporarily.

The auxiliary interface then operates temporarily in "Auxiliary input" mode.

8009237/RB47/2007-08-03

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-29

Page 134

Chapter 10

Appendix

Operating Instructions CLX490 Compact OMNI Scanner

Entering the bar code using the Terminal Emulator function in CLV-Setup 1.

Click on the toolbar. The Terminal Emulator is launched. The CLX is in Reading mode.

2.

Click the EXTENDED radio button in the TERMINAL MODE section. The start and stop characters used by the Terminal Emulator are displayed at the top of the screen, on the left and right of the text input field. Fig. 10-16 shows the Terminal Emulator window in extended mode.

3.

Use the drop-down lists to set the start and stop characters to NUL.

4.

Enter the data content of the bar code (character string) on the keyboard. Use the backspace key to correct any input errors. The data content must not contain control characters.

5.

Press the [RETURN] or [ENTER] key. The CLX then interprets all further characters as a new data string. CLV-Setup sends the character string to the CLX and deletes the entry in the text field. The CLX does not send an echo.

6.

Once the active reading pulse has ended, the CLX sends the data received from the PC to the host via the host interface.

Fig. 10-16: CLV-Setup: auxiliary input on the Terminal Emulator

10-30

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03

Page 135

Operating Instructions

Appendix

Chapter 10

CLX490

Entering a bar code using a terminal/PC keyboard 1.

Connect the terminal /PC with Terminal Emulation program to the auxiliary interface on the CLX (via AMV/S60). For the pin assignment, see Chapter 5.5.6 Connecting the PC, Page 5-15.

2.

Set the communication parameters and data output format as shown in Table 10-7.

Parameter

Value

Data transmission rate

9,600 bd

Data bits

8

Parity

None

Stop bits

1

Data output format

Data e. g. 1234 terminator CR

Table 10-7: Communication parameters on the terminal/PC for the auxiliary input

3.

Enter the data content of the bar code on the keyboard. The terminal sends the individual characters to the CLX immediately. Use the backspace key to correct input errors.

4.

Terminate the data content with the control character <CR>. The CLX then interprets all further characters as a new data string and ignores other control characters. The data content itself must not contain any control characters.

5.

Once the active reading pulse has ended, the CLX sends the data received from the PC to the host via the host interface.

Entering bar codes using a handheld scanner with decoder 1.

Connect the handheld scanner with decoder to the auxiliary interface of the CLX (via AMV/S60). For the pin assignment, see Chapter 5.5.6 Connecting the PC, Page 5-15.

2.

Set the data format and communication parameters on the handheld scanner as shown in Table 10-7.

3.

Read the bar code with the handheld scanner. Once the active reading pulse has ended, the CLX sends the data received from the PC to the host via the host interface.

If you connect a SICK Hand-held Scanner from the IT 38xx/46xx/48xx/58xx series, set the communication parameters and data output (data + terminator) as shown in Table 10-8. Parameter

Value

Data transmission rate

9,600 bd

Data bits

8

Parity

No

Stop bits

1

Data interface

RS 232

Prefix (Header)

Clear all Prefixes

Suffix (Terminator)

CR

Table 10-8: Communication parameter settings for the SICK Hand-held Scanner from the IT 38xx/46xx/48xx/58xx series

8009237/RB47/2007-08-03

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-31

Page 136

Chapter 10

Appendix

Operating Instructions CLX490 Compact OMNI Scanner

10.10.2 Connection to the Profibus DP See Operating Instructions "BMV/BMH10 for Profibus DP" (order no. 8008825, English edition). 10.10.3 Connection to the DeviceNet See Operating Instructions "BMV/BMH10 for DeviceNet" (Order no. 8008972, English edition). 10.10.4 Connection to Interbus-S See Technical Information "BMS10/20 for Interbus-S" (Order no. 8007546, English edition). 10.10.5 Connection to Ethernet TCP/IP See Operating instructions "BMV/BMH10 for Ethernet" (Order no. 8009398, English version) 10.10.6 Building a CAN Scanner Network See Operating Instructions "Using the CAN interface" (Order no. 8009180, English edition). 10.10.7 Integration in an OPS reading system See Operating Instructions "Omni Tracking System OTS400" (Order no. 8008869, English edition).

10-32

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03

Page 137

Operating Instructions

Appendix

Chapter 10

CLX490

10.11 Replacing a CLX (copying the parameter set) There are two methods of replacing a CLX and transferring the current parameter set to the new device: • by downloading the parameters from CLV-Setup

• by importing the parameter set from the external memory

The parameter set can only be transferred between identical device types (e. g. from one CLX490-0010 to another CLX490-0010, etc.). 10.11.1 Downloading the parameter set To download the parameter set, you must connect a PC running the "CLV-Setup" software to the replacement device. The parameter set of the CLX that is to be replaced must be available as a configuration file in CLV-Setup, otherwise the device must be parameterized from scratch. 1.

Disconnect the power supply to the AMV/S60 Connection Module (of the CLX).

2.

Disconnect all cable connectors from the CLX.

3.

Remove the CLX from the bracket. Before doing so, mark the position and alignment on the bracket/station.

4.

Mount, align, and connect the replacement device.

5.

Connect the PC to the auxiliary interface on the CLX using a 3-core RS 232 data cable (null modem cable)(AMV/S60: connect the PC to the internal, 9-pin "Service" plug). See Chapter 5.5.6 Connecting the PC, Page 5-15.

6.

Switch on the power supply to the AMV/S60. Once the CLX has started, the "Device Ready" LED lights up.

7.

Switch on your PC and start Windows.

8.

Start CLV-Setup. If the communication parameters on the PC and CLX are identical, CLV-Setup uploads the parameter set from the CLX and displays the values on the tabs.

9.

Open the archived parameter set as a configuration file "*.scl" in CLV-Setup and download it to the CLX.

10. Confirm the dialog box by choosing the TEMPORARY storage option. 11. Check whether the CLX reads the bar codes correctly. Correct the parameter settings if necessary. 12. Finally, download the tested parameter set to the CLX and save it with the PERMANENT storage option. The parameter set is transferred permanently to the replacement device. 13. Save the modified parameter set as a new configuration file in CLV-Setup. Troubleshooting If the software version on the replacement device is older than the version on the old device (e. g. new device is from warehouse stock), the parameter set transferred may contain coded parameters or parameter values that cannot be interpreted by the older software. The new device, however, outputs an error message in CLV-Setup for each of these parameters/values when the parameter set is downloaded.

8009237/RB47/2007-08-03

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-33

Page 138

Chapter 10

Appendix

Operating Instructions CLX490 Compact OMNI Scanner

¾

Check whether all of the parameter settings used are necessary to configure the CLX for the current reading application. If necessary, replace the software version in the new device.

If the software version on the new device is more recent than that on the old one, the default settings in the imported parameter set will include parameters that were not contained in the old version. ¾

Upload the parameter set and check whether the new parameters are relevant for configuring the CLX for the current reading application. If necessary, change the parameter values and download the parameter set to the CLX again. Save the new parameter set as a configuration file in CLV-Setup.

See also Chapter 10.6.10 Unknown parameters, Page 10-23. 10.11.2 Importing the parameter set from the external memory A PC does not have to be connected to import the parameter set from the external memory. The parameter set in the external memory must contain an up-to-date copy of the set used by the CLX that is to be replaced. Otherwise, the replacement device will import a different parameter set to its RAM when it is started. The start option in the device must be set to START WITH EXTERNAL PARAMETERS. This is the default setting. 1.

Switch off the power supply to the AMV/S60 Connection Module (of the CLX).

2.

Remove the connector cover (containing the parameter memory) from the CLX.

3.

Remove the CLX from the bracket. Mark the position and alignment of the CLX on the bracket/station.

4.

Mount the connector cover on the terminals correctly and screw it into place.

5.

Mount and align the replacement device.

6.

Switch on the power supply to the AMV/S60. The CLX starts and loads the parameter set from the external memory to the RAM. The "Device Ready" LED blinks for approx. 10 s and then lights up constantly.

The parameter set is transferred temporarily to the replacement device. It is lost when the device is switched off but is loaded again from the external memory the next time the CLX starts. See also Chapter 10.3.8 Replacing a CLX, Page 10-11. Troubleshooting If the software version on the replacement device is older than that of the parameter set in the external memory (e. g. if the replacement device originated from the warehouse), the loaded parameter set may contain parameters or parameter values that cannot be interpreted by the older software. In this case, the "Device Ready" and "Read Result" LEDs blink together for approx. 10 s, after which the "Device Ready" LED lights up constantly. See also Chapter 10.6.10 Unknown parameters, Page 10-23. If the software on the replacement device is newer than that of the parameter set in the external memory, the parameter set loaded from the external parameter memory to the replacement device will contain new parameters that are set to the default values.

10-34

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03

Page 139

Operating Instructions

Appendix

Chapter 10

CLX490

10.12 Ordering information 10.12.1 CLX490 Compact OMNI Scanner Order no.

Type (red light)

Scanning method

Resolution

Heater

1019318

CLX490-0010

CLX490 Compact OMNI Scanner from 0.30 mm no

1019319

CLX490-0011

CLX490 Compact OMNI Scanner from 0.30 mm yes

Table 10-9: CLX variants

10.12.2 Accessories: Mounting accessories Order No.

Description

See figure

2016110

Quick-clamping device, complete with securing material

–

2022996

Angle bracket, with 2 screws M6 x 10 mm, self-locking

Fig. 10-17, Page 10-39

Table 10-10: Accessories: mounting accessories

10.12.3 Accessories: Connection modules Order No.

Type

Description

1017134

AMV60-011

Connection Module for a CLX490 without heater, with 1 x 15-pin D Sub HD device socket/plug, terminal strips (signal distributor) for connecting the data and function interfaces, internal 9-pin D Sub "Service" plug, strain-relief clamps, polycarbonate housing, enclosure rating IP 30 (max. IP 54), operating voltage 18 to 30 V DC, operating temperature 0 to +40 °C

1017139

AMS60-013

As AMV60-011, with integrated power pack: 230 V AC 50 Hz/24 V DC

1017140

AMS60-012

As AMV60-011, with integrated power pack: 115 V AC 50 to 60 Hz/24 V DC

1017387

AMS60-023

As AMS60-013, with 2-row LCD

1017391

AMV30-071

Connection Module for two CLX490 without heater, with 2 x 15-pin D Sub HD device socket/plug, terminal strips (signal distributor) for connecting the data and function interfaces, two 9-pin D Sub "Service" plugs, strain-relief clamps, polycarbonate housing, enclosure rating IP 30 (max. IP 54), operating voltage 18 to 30 V DC, operating temperature 0 to +40 °C

6021105

AMV100-011

Universal Connection Module for one CLX 490 with/without heater, for the CLX490 with 1 x 15-pin D Sub HD device socket/plug, terminal strips (signal distributor) for connecting the data and function interfaces, internal 9-pin D Sub "Service" plug, strain-relief clamps, cast aluminum housing, enclosure rating IP 54 (enclosure rating IP 65 with connector cover), operating voltage 18 to 30 V DC, operating temperature 0 to +40 °C

6021106

AMV100-012

As AMV100, but for two CLX490 with/without heater

6007655

–

Power cable for AMS60, 3-wire, length 2 m, with 3-pin connector (grounding) and one open end (stripped)

Table 10-11: Accessories: connection modules

8009237/RB47/2007-08-03

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-35

Page 140

Appendix

Chapter 10

Operating Instructions CLX490 Compact OMNI Scanner

10.12.4 Accessories: Bus connection modules Order No.

Type

Description

6020896

BMV10-0111

Bus Connection Module for connecting a CLX490 to a Profibus DP, for the CLX490 with 1 x 15-pin D Sub HD device socket/plug, bus connector, terminal strips (signal distributor) for connecting the RS 232 and function interfaces, internal 9-pin D Sub "Service" plug, strain-relief clamps, cast aluminum housing, enclosure rating max. IP 54 (enclosure rating max. IP 65 with connector cover), operating voltage 20 to 30 V DC, operating temperature 0 to +40 °C

6020893

BMH10-0111

Bus Module for connecting a CLX490 to a Profibus DP, with screw terminals, 9-pin D Sub plug for the bus, without housing, for DIN rail mounting, enclosure rating max. IP 20, operating voltage 10 to 30 V DC

6021190

BMV10-0311

Bus Connection Module for connecting a CLX490 to a DeviceNet, with screw terminal for the bus, see BMV10-0111

6021188

BMH10-0111

Bus Module for connecting a CLX490 to a DeviceNet, see BMH10-0111

1012683

BMS20-0113

Bus Connection Module for connecting a CLX 490 to an Interbus-S, for the CLX490 without heater, 15-pin D Sub HD device socket/plug. With 9-pin D Sub plug/socket (in/out) for the bus, terminal strips (signal distributor) for connecting the data and function interfaces, internal 9-pin D Sub "Service" plug, integrated power pack 230 V AC 50 Hz/ 24 V DC, strain-relief clamps, enclosure rating IP 30 (max. IP 54), operating temperature 0 to +40 °C

1012684

BMS20-0112

As BMS20-0113, with integrated power pack 115 V AC 50 to 60 Hz/ 24 V DC

6025757

BMV10-0411

Bus connection module for connecting a CLX490 to Ethernet. TCP/IP. TCP/IP communication, data transmission rate 10 MBit/s. For the CLX 490 with a 15-pin D Sub HD device plug/socket. With a 8-pin RJ-45 bus socket, terminal strips (signal distributors) for wiring the RS 232 data interface and the functional interfaces, a internal 9-pin D Sub "Service" plug, cable grips, die-cast aluminum housing, enclosure rating max. IP 54 (enclosure rating max. IP 65 with a plug hood), operating voltage 20 to 30 V DC, operating temperature 0 to +40 °C

6025756

BMH10-0411

Bus module for connecting a CLX490 to Ethernet TCP/IP. TCP/IP communication, data transmission rate 10 MBit/s. With terminal screws, a 8-pin RJ-45 bus socket, no housing, for top-hat-rail installation, enclosure rating max. IP 20, operating voltage 10 to 30 V DC, operating temperature 0 to +40 °C

6022140

BMV10-0431

As BMV10-0411, but with FTP communication, data transmission rate 10/100 MBit/s

6025748

BMH10-0431

As BMH10-0411, but with FTP communication, data transmission rate 10/100 MBit/s

6007655

–

Power cable for BMS20, 3-wire, length 2 m, with 3-pin connector (grounding) and one open end (stripped)

Table 10-12: Accessories: bus connection modules

10-36

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03

Page 141

Appendix

Operating Instructions

Chapter 10

CLX490

10.12.5 Cables, external parameter memories and plug cover a) CLX without heater Temperature range of connection material: Stationary: –30 to +70 °C; moving: 0 to +70 °C Order No.

Description

Wires

Length Connection

2020302

Connection cable for data interfaces ("Host/Term") or function interfaces ("I/O"), ∅ 8 mm, shielded, with 15-pin D Sub HD socket and 15-pin D Sub HD plug. Required: 2 per CLX

15 x 0.25 mm

2021815

As no. 2020302, but longer

15 x 0.25 mm2

2020303

2

3m

CLX to AMV/S60 AMV30-071 BMV10/BMS20

10 m as above

Connection cable for data interfaces ("Host/Term"), ∅ 8 mm, shielded, with 15-pin D Sub HD socket and one open end (stripped). Required: 1 per CLX

15 x 0.25 mm

2

3m

CLX to host

2020264

Connection cable for function interfaces and power supply ( "I/O"), ∅ 8 mm, shielded, with 15-pin D Sub HD plug and one open end (stripped). Required: 1 per CLX

15 x 0.25 mm2

3m

CLX to sensors PLC and non-SICK Power pack

2020307

Connector cover with parameter memory (EEPROM), enclosure rating IP 65, with two connection cables, each ∅ 8 mm, shielded, with 15-pin D Sub HD socket and 15-pin D Sub HD plug. Required: 1 per CLX each 15 x 0.14 mm2

3m

CLX to AMV/S60 AMV30-071 BMV10

2020981

Connector cover with parameter memory (EEPROM), enclosure rating IP 65, with two connection cables, each ∅ 8 mm, shielded, two open ends (stripped). Required: 1 per CLX each 15 x 0.14 mm2

3m

CLX to host, sensors, PLC and nonSICK Power pack

2020308

Connector cover with parameter memory (EEPROM), enclosure rat- each ing IP 65, with two connection cables ∅ 8 mm each, shielded, 10 x 0.2 mm2 with 9-pin D Sub HD plug and one open end (stripped). Required: 1 per CLX

3 mm

CLX to BMS20

2014054

RS 232 data cable (null modem cable), ∅ 5 mm, shielded, with two 9- 3 x 0.34 mm2 pin D Sub sockets (Pin2 (RxD) and Pin 3 (TxD) crossed)

3m

PC to AMV/S BMV10/BMS20

6010088

Data cable, ∅ 6.6 mm, shielded, for connection cables up to 3 m

15 x 0.09 mm2

Meter ware

Free wiring

6007508

Data cable, ∅ 8.5 mm, twisted pair, shielded

2 x 2 x 0.23 mm2 Meter ware

SICK network (RS 485)

Table 10-13: Accessories: cables and connector covers for the CLX without heater

Note

8009237/RB47/2007-08-03

Other cable lengths/types for CLX without heater available on request.

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-37

Page 142

Appendix

Chapter 10

Operating Instructions CLX490 Compact OMNI Scanner b) CLX with heater Temperature range of connection material: Stationary: –50 to +70 °C; moving: –40 to +70 °C Order No.

Description

Wires

Length Connection

2021689

Connector cover with with parameter memory (EEPROM), enclosure rating IP 65, with 2 connection cables, each ∅ 8 mm, shielded, with 15-pin D Sub HD socket and 15-pin D Sub HD plug Required: 1 per CLX each 15 x 0.14 mm2

3m

CLX490 an AMV100/200

2021298

2 x connector cover, enclosure rating IP 65, with 2 connection cables, each ∅ 6.7 mm, shielded. Required: 1 per CLX each 13 x 0.14 mm2 + 2 x 0.75 mm2

3m

CLX490 an AMV100/200

2021299

As no. 2021298, but longer connection cables as above

10 m as above

2021267

Connector cover, enclosure rating IP 65, with 2 connection cables, each ∅ 6.7 mm, shielded, two open ends (stripped). Required: 1 per CLX

1 x 18 x 0.14 mm2 + 1 x 2 x 0.75 mm2

3m

CLX490 to host, sensors, PLC and nonSICK Power pack

Table 10-14: Accessories: cables and connector covers for the CLX with heater

Note

Other cable lengths/types for CLX with heater available on request. 10.12.6 Plug-in connections

Order No.

Description

6009438

D Sub connector housing (metal) for 9-pin or 15-pin HD inserts

6007335

D Sub connector insert, 9-pin socket connector

6010019

D Sub connector insert, 15-pin HD socket connector

6010020

D Sub connector insert, 15-pin HD pin connector

Table 10-15: Accessories: plug-in connections

10.12.7 Reading pulse generators The SICK catalog "SENSICK Sensors for Automation" (order no. 8006530, English edition) contains a large selection of photoelectric switches and photoelectric proximity switches as well as the associated accessories (brackets, connection cables).

10-38

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03