Page 143

Operating Instructions

Appendix

Chapter 10

CLX490

10.13 Dimensioned drawings of the accessories 10.13.1 Angle bracket, no. 2022996 Enclosed to securing the CLX: 2 x cylinder head screws M6 x 10 mm, self-locking

10.9

9

50 30 6.5

6.2 Drill holes for fixation of CLX

108

40

72

6.2

142 6.2

Fig. 10-17: Dimensions of the angle bracket, single No. 2022996

8009237/RB47/2007-08-03

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-39

Page 144

Appendix

Chapter 10

Operating Instructions CLX490 Compact OMNI Scanner

10.14 Supplementary documentation Order No.

Title

Contents

8008296

"AMV/S60" Operating Instructions

Description for connecting the CLX without heater to the host/PLC/sensor via the AMV/S60 Connection Module

8008648

"AMV30-071" Operating Instructions

Description for installing two CLX without heaters to the host/PLC/sensor via the AMV30-071 connection module

8008879

"AMV100/200" Operating Instructions

Description for connecting 1 (2) CLX without/with heater to the host/PLC/ sensor via the AMV100 (AMV200) Connection Module

8007675

"Master/Slave with CLV Bar Code Scanners" Description of building a daisy-chain configuration Technical Information (master/slave or data forwarding)

8008825

"BMV/BMH10 for Profibus DP" Operating Instructions

Description for connecting the CLX to the Profibus/PLC/sensor via the BMV/BMH10 Bus Connection Module

8008972

"BMV/BMH10 für DeviceNet" Operating Instructions

Description for connecting the CLX to the DeviceNet/PLC/sensor via the BMV/BMH10 bus connection module

8007546

"BMS10/20 for Interbus-S" Technical Information

Description for connecting the CLX to the Interbus/SPS/sensor via the BMS20 Bus Connection Module

8009398

"BMV/BMH10 for Ethernet" Operating Instructions

Description for connecting the CLX to the Ethernet/PLC/sensor via the BMV/BMH10 Bus Connection Module

8008869

"Omni Tracking System OTS400" Operating Instructions

Description of the integration of the CLX490 in an omnidirectional OPS reading system

8009180

”Application of the CAN interface” Operating Instructions

Description for building a CAN network (electrical connection, configuration of the CLX, functions)

Table 10-16: Supplementary documentation in English language

10.14.1 CLV Connect (from version 1.9) Diagrams showing you how to connect the AMV/S60 Connection Module are also available in the “CLV Connect“ PC program. This software is available on the “Manuals & Software“ CD-ROM, which is included in the scope of delivery of the CLX. The software can also be downloaded from the SICK home page (www.sick.com) at “Service&Support/Downloadpool“. It can be called up using a standard HTML browser (e. g. Internet ExplorerTM).

10-40

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03

Page 145

Operating Instructions

Appendix

Chapter 10

CLX490

10.15 Glossary For further terms, please refer to the online help "CLV-Setup Help". Aspect ratio Ratio code height (bar length) to code length (numer of characters). Using the SMART Decoder even bar codes with very small code height can be read. Autofocus function Ability of the CLX to detect the distance of the objects during the reading operation without external sensors in order to adapt the focus position to the reading plane of the bar codes. Auxiliary input Special function on Ö the auxiliary interface. Used to enter bar code data subsequently in order to complete reading results sent to the host. Auxiliary interface Auxiliary data interface (RS 232) on the CLX with fixed data output format. Used to connect the "CLV-Setup" program to the CLX so that it can operate and configure the device. Also used to output Ö system and error messages. Can be assigned various functions. CAN interface Can be used for building a quick SICK specific CAN Scanner Network with several functions (e.g. multiplex function, master/slave configuration) or for the integration into an existing CAN network according to the CANopen protocol. Capture range Zone around a moving bar code created by the CLX using the increment management and reading angle comparison functions. Enables bar codes with identical contents and code type to be separated. CLV-Setup PC program that runs on Windows 95TM /98TM, Windows NT4.0TM, Windows 2000TM, Windows XPTM and is used to parameterize the CLX offline (adjust the device to the local conditions) and operate it online. The parameter set is exchanged with the CLX by Ö uploading and Ö downloading it. CLV-Setup Help Online help function that provides support for using the "CLV-Setup" program. The help function explains the CLX parameters and their permissible values and can be launched directly from CLV-Setup in an HTML browser, such as Internet ExplorerTM. Code geometry Length and height dimensions of the bar code. Code Info/Separator Data block in the reading result on the Ö host interface. Used to provide additional information about the bar codes. Can be attached to the bar code as a prefix or suffix. Contains up to 10 elements, consisting of reading diagnosis data and/or constants (control characters,

8009237/RB47/2007-08-03

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-41

Page 146

Chapter 10

Appendix

Operating Instructions CLX490 Compact OMNI Scanner letters, digits), depending on the configuration. The "Code-Info/Separator" block is empty in the default setting of the CLX. Command strings, commands CLX user interface – alternative to the "CLV-Setup" program. Basic, yet clearly structured command language for modifying the CLX parameter sets online. Accesses the CLX command interpreter directly. Special programming activities are required to use the command strings from the host. CLX490 Compact OMNI Scanner Scanner with a scan line deflected by two mirrors in the device cover. The scan line is folded and crossed which allows omnidirectional reading of bar codes. Configuration file File in the "CLV-Setup" program that archives the entire Ö parameter set of the CLX. Can also be printed out in tabular form. Data forwarding Option of forwarding data sent by the host transparently to a terminal via the CLX using an identifier. Data can also be forwarded in the opposite direction. Furthermore, this function also allows data received on one of the serial interfaces to be output again straight away on one of the same interfaces (echo). Data output string Structured data telegram in the Ö reading result output by the CLX on the Ö host interface. The structure of the data string is flexible and can be adapted to a large extent to the subsequent data processing task. The data output format of the Ö auxiliary interface, on the other hand, cannot be changed. Decoder, decoding Code-type-specific evaluation routine for reconstructing the read bar code in electronic form in order to decode its data content. Distance configuration Data record in the CLX for defining a Ö focus position for the laser beam for Ö dynamic focus control. The focus position must be entered on the READING CONFIGURATION tab in the "CLV-Setup" program for this purpose. The depths of field for the individual focus positions are shown as a function of the resolution values in the specification diagrams. Download Method of transferring the Ö parameter set that was modified with the Ö CLV-Setup program offline from the PC to the CLX. CLV-Setup either always transfers a complete copy to the memory (RAM) of the CLX (DOWNLOAD TO CLV) or just the parameter previously processed using the context menu of the right mouse button (DOWNLOAD PARAMETER) or all parameters of the displayed tab (DOWNLOAD PARAMETERS OF THIS VIEW). You can overwrite the existing parameter set in EEPROM of the CLX by choosing the "Permanent" save option.

10-42

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03

Page 147

Operating Instructions

Appendix

Chapter 10

CLX490

Dynamic focus control Function for shifting the focal point of the laser beam across a wide range in the reading plane. The dynamic focus control function is event controlled (e. g. by the distance detector) or dynamic in the Ö Autofocus function. Error messages Messages in Ö plain text or coded (3-digit) that are used to identify a malfunction on the CLX in Reading mode. The messages are output on the auxiliary interface only. Exception: ST = 3 (device error), which is also output on the host interface. The error messages can be displayed in the Terminal emulator in the "CLV-Setup" program. Error status Identifier output with the reading result by the CLX for errors that were diagnosed while the bar code was being read. The entry for the host interface is made in the "Code-Info/Separator" block of the Ö data output string and must be enabled using the parameters (for the CLX disabled by default). Focus position Distance of the focal point of the emitted laser beam in front of the reading window. Can be varied using the optical components in the CLX. Creates a distance-specific depth of field (DOF) in which he bar code can be detected. Functional interfaces Digital switching inputs and outputs on the CLX. Good Read The CLX successfully detected a bar code or the required number of bar codes specified by the evaluation parameters during the Ö reading pulse. Header Data block in the reading result on the Ö host interface. Used as a header in the Ö data output string for the subsequent data content of the bar codes. Contains up to 10 elements, consisting of reading diagnosis data and/or constants (control characters, letters, digits), depending on the configuration. The "Header" block is empty in the default setting of the CLX. Host interface Main data interface on the CLX with configurable data output format. Used to output the Ö reading result in telegram form to the host/PLC. Used as gateway in the CAN Scanner Network. Can be physically switched to RS 232 or RS 422/485. It supports various transmission protocols. Increment management Used in certain applications to separate bar codes with identical contents that move during the reading procedure and assign them to the objects. Master/slave configuration Special arrangement for connecting up to max. 10 CLX to one reading station (e. g. left/right read) using the CAN interface. Thanks to the master, the entire network appears as one device to the host.

8009237/RB47/2007-08-03

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-43

Page 148

Chapter 10

Appendix

Operating Instructions CLX490 Compact OMNI Scanner

Multiple read Variable number of reading operations that must provide identical reading results (data content) of the same bar code before the CLX outputs the result. No Read Special, parameterizable data block as a substitute for bar codes, which were expected but not detected, in the data output string on the host interface for Ö No Read. Comprises a variable combination of the error string and the Ö "Code-Info/Separator" block. No Read format Special, parameterizable data block as a substitute for bar codes, which were expected but not detected, in the data output string on the host interface for Ö No Read. Comprises a variable combination of the error string and the Ö separator. Object polling The CLX automatically detects a current object entering or leaving the reading field without any external sensors. Parameter set Data record used to initialize and activate the functions implemented in the CLX. With downloading and uploading the parameter set is transferred form CLV-Setup to the CLX or from the CLX to CLV-Setup. Parameter memory, external Optional accessory integrated in a connector cover. Enables devices to be conveniently replaced by storing a copy of the CLX parameter set (EEPROM). The replacement device then accesses this parameter set directly and does not have to be configured manually. Percentage evaluation Special operating mode in which the quality of the reads (not those of the barcodes, however) is assessed statistically. The bar codes must be stationary. The CLX carries out 100 scans and evaluates the reading quality. It then outputs the reading results on the Ö auxiliary interface every 2 s together with the reading diagnosis data. Plain text Legible form of a CLX message. The CLX outputs special messages in coded form, e. g. the result of the self-test is represented as three digits. Reading angle (RA value) Position of the first dark bar in a detected bar code along the Ö scan line. Calculated by the CLX for each scan and can be used, for example, to separate bar codes with identical data contents. The active evaluation range in the scan line can be restricted for Ö decoding purposes by specifying the maximum and minimum reading angle value for the application. Reading diagnosis data Data directly derived from the reading procedure by the CLX. This data enables the quality of the read to be assessed. The data is always output on the Ö auxiliary interface together with the reading result. Only output on the host interface if enabled on the DATA STRING tab in the "CLV-Setup" program (for the CLX disabled by default).

10-44

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03

Page 149

Operating Instructions

Appendix

Chapter 10

CLX490

Reading field height Length of the Ö scan line that is available for detecting the bar code in the reading plane. Reading interval Timeslot in which the CLX activates the laser diode and attempts to detect valid bar codes from the information read. The reading interval may be shorter than the external reading pulse, depending on the selected output mode for the reading result. Reading pulse Clock pulse applied externally to the CLX to trigger the internal Ö reading interval. Can be supplied by a photoelectric reflex switch or a command from the host on the serial interface. Reading range (DOF) Depth of field about the focal point of the laser beam on two sides. The extent of the reading range depends on the resolution and reading distance. Reading result Electronic representation of the data content of the read bar code together with the Ö reading diagnosis data in one Ö data output string that is generated after the reading pulse has elapsed. The reading result on the auxiliary interface has a fixed format (content and output format); the reading result on the host interface can be configured separately for Good Reads and No Reads. Special characters can also be added if necessary. Result status output Function of the four "Result 1" to "Result 4" switching outputs in Reading mode. Signals the status of the reading result without indicating its contents (e. g. Good Read). You can assign a status to each output on the DEVICE FUNCTION tab in CLX. The "Read Result" LED is linked to the "Result 2" output. Scan line See CLX490 Compact OMNI Scanner. Sending point Point at which the reading result is output with respect to the start of the Ö reading pulse and the internal Ö reading interval. SMART decoder Specially developed Ö decoder for reading bar codes with an extremely small code height and for poor-quality or contaminated code prints. Specification diagrams Diagrams for reading the resolution-specific depth of field (DOF) for specific focus positions. Splitter Data block in the reading result of the Ö host interface. Used to separate the data content of the bar codes. Contains up to 5 elements, consisting of constants (control characters, letters, digits), depending on the configuration. The "Splitter" block is empty in the default setting of the CLX.

8009237/RB47/2007-08-03

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-45

Page 150

Chapter 10

Appendix

Operating Instructions CLX490 Compact OMNI Scanner

Standard decoder Tried-and-tested Ö decoder from the CLV product family. Suitable for applications with an adequate code height, limited tilt, and high-quality code prints. Storage in the CLX The application-specific Ö parameter set can be stored temporarily or permanently in the CLX. If it is stored temporarily in the RAM, it is lost as soon as the power supply is switched off. Parameter sets that are stored permanently are transferred to the EEPROM in the CLX and remain active as the current data record when the power supply is switched off. The default setting is not affected by this and is stored in a read-only memory (ROM). Switching sequence Focus control function for event-controlled switching. Sequence of focus position settings with associated depths of field. The numbers of the active Ö distance configurations are entered at the required position in the assignment table for this purpose. System messages Messages Ö in plain text used to output the operating status of the CLX. The messages are output on the auxiliary interface only and can be displayed in extended mode in the TERMINAL EMULATOR of the "CLV-Setup" program. Teach-in Method of programming the information required to adjust the CLX to the reading application in Parameterization mode. Example: teaching in the background for the Autofocus function, also known as a Ö distance profile. Terminator Data block in the reading result on the Ö host interface. Used to terminate the data content of the bar code. Contains up to 10 elements, consisting of reading diagnosis data and/or constants (control characters, letters, digits), depending on the configuration. The "Terminator" block is empty in the default setting of the CLX. Upload Method of transferring the Ö parameter set from the CLX to the PC Ö using the CLV-Setup program. CLV-Setup either transfers a complete copy of the current parameter set from the memory (RAM) of the CLX (UPLOAD TO CLV) or just the parameter previously processed using the context menu of the right mouse button (UPLOAD PARAMETER) or all parameters of the displayed tab (UPLOAD PARAMETERS OF THIS VIEW). Displays the current parameter values on the tabs. Prerequisite for modifying the current parameter set. User interface Windows-based PC software "CLV-Setup" for operating and configuring the CLX.

10-46

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03

Page 151

Operating Instructions

Appendix

Chapter 10

CLX490

10.16 EC Declaration of Conformity Fig. 10-18 shows the scaled down copy of the EC Declaration of Conformity (page 1). ¾

The complete EC Declaration of Conformity with the listing of the device versions and the fullfilled standards can be requested from SICK AG.

Fig. 10-18: Reproduction of the declaration of conformity (Page 1, reduced in size)

8009237/RB47/2007-08-03

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-47

Page 152

Appendix

Chapter 10

Operating Instructions CLX490 Compact OMNI Scanner

Notes:

10-48

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03