Page 85

Maintenance

Operating Instructions

Chapter 7

CLX490

7

Maintenance 7.1

Maintenance during operation

The CLX functions maintenance free. Maintenance is not required to guarantee laser class 2 of the CLX. Note

Don’t open the device. The warranty will be forfeited if the device is opened. The CLX indicates any faults or malfunctions by outputting coded system and error messages (e. g. "CLV SYS-Failure: 071") via its auxiliary interface. The messages are displayed in the "CLV-Setup" program window in the fourth field from the left on the bottom, in the status line (see also Chapter 8.3 Error messages, Page 8-2). CLV-Setup logs the messages in a file.

7.2 Recommendation

Cleaning the CLX

In order to make use of the full optical reading capacity of the CLX, the reading window should be checked regularly (e. g. weekly) for soiling. This is especially recommended when operating the device in harsh conditions (dust, abrasion, humidity, finger prints, etc.). 7.2.1

Cleaning the front window

Laser beam can cause blindness! The CLX uses a class 2 red-light laser. Looking directly at the laser beam can seriously damage your eyesight. ¾

As with sunlight, never look directly into the laser beam.

¾

Switch off the device while it is being cleaned.

¾

Never look directly into the reading window while the device is in operation.

Damage on the reading window! The reading window is made of glass. Scratches and streaks on the window will reduce the reading performance. ¾

Do not use aggressive cleaning agents.

¾

Do not use cleaning agents which cause increased abrasion (e. g. powder).

¾

Avoid cleaning motions at the reading window which could cause scratches or abrasion.

Cleaning the reading window Note

8009237/RB47/2007-08-03

Electrostatic charges cause dust particles to stick to the reading window. This effect can be combated by using anti-static SICK synthetic cleaner (no. 5600006) in combination with a SICK lens cloth (no. 4003353). ¾

Use a clean, soft brush to free the reading window (Fig. 7-1, Page 7-2) from dust.

¾

If necessary, additionally clean the reading window with a clean, damp, lint-free cloth and a mild, anti-static window cleaning fluid.

© SICK AG · Division Auto Ident · Germany · All rights reserved

7-1

Page 86

Chapter 7

Maintenance

Operating Instructions CLX490 Compact OMNI Scanner

Clean here

Fig. 7-1:

Cleaning the reading window

If the reading window is scratched or damaged (cracked, broken), it must be replaced. Please contact the SICK Service. Cleaning the housing In order to ensure sufficient cooling for the CLX, make sure that the housing is always clean. ¾

Use a soft brush to free the housing from dust.

¾

If necessary, clean the LEDs on the rear of the device.

7.2.2

Cleaning other optical surfaces

If an external reading pulse generator and/or object-height detection sensors are used (e.g. photoelectric reflex switches), further sensors with optical effective surfaces can be installed. Soiling of these surfaces can cause incorrect switching behaviour. ¾

In order to prevent incorrect switching behaviour, remove soiling from the optical effective surfaces of the external sensors.

Clean here

Fig. 7-2:

7-2

Cleaning the external optical sensors (reading pulse generator, object-height detector)

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03

Page 87

Operating Instructions

Maintenance

Chapter 7

CLX490

7.3

Checking the incremental encoder

If an incremental encoder is used, check the correct position on the conveyor. ¾

7.4

Ensure that the incremental encoder always contact the conveyor so that the friction wheel turns without slipping.

Disposal

Irreparable devices or devices that are no longer required must be disposed of in an environmentally-friendly manner: 1.

Always observe the applicable national waste disposal regulations.

2.

Remove the CLX housing.

3.

Remove the electronic modules.

4.

Send the chassis and cover (aluminium) to be recycled.

5.

Send the electronic modules for disposal as problem waste.

At present, SICK AG does not accept any unusable or irreparable devices.

8009237/RB47/2007-08-03

© SICK AG · Division Auto Ident · Germany · All rights reserved

7-3

Page 88

Maintenance

Chapter 7

Operating Instructions CLX490 Compact OMNI Scanner

Notes:

7-4

© SICK AG · Division Auto Ident · Germany · All rights reserved

8009237/RB47/2007-08-03