Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of MINI Hawk High Performance Imager User Manual

Manual · Microscan

MINI Hawk High Performance Imager User Manual

Manual380 pagesPDF 5.2 MB

User manual for the Omron Microscan MINI Hawk High Performance Imager, a fixed-mount barcode reader set up with ESP or serial commands.

Download the PDF5.2 MB

Covers · 1 model

The models it covers

Summary

What is in it

The full user manual for the MINI Hawk High Performance Imager from Omron Microscan. It starts with an eleven-step quick start, then explains the ESP (Easy Setup Program) software, host and auxiliary port communications including USB HID, calibration, read cycle and trigger settings, the linear and 2D symbologies, I/O parameters, symbol quality output, matchcode, camera and IP setup, the configuration database, terminal, utilities and output format.

Its parts

  1. Quick Start
  2. Using ESP
  3. Communications
  4. Calibration
  5. Read Cycle
  6. Symbologies
  7. I/O Parameters
  8. Symbol Quality
  9. Matchcode
  10. Camera and IP Setup
  11. Configuration Database
  12. Terminal
  13. Utilities
  14. Output Format

From the manual

Key facts from this manual

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

The Omron Microscan user manual (2019) for the MINI Hawk High Performance Imager in its 3 Megapixel, High Resolution and High Speed versions. It walks through setup with the EZ Button, ESP software and serial commands, and covers communications, calibration, read cycles, symbologies, I/O, symbol quality, matchcode and output format. Appendices give general and electrical specifications, connector pin assignments, trigger wiring and the USB virtual COM port driver.

Read for this summary: pages 2, 8 to 11, 13 to 18, 22 to 24, 185 to 186, 341 to 349 and 367 to 369 of 380.

Device
Compact imager with X-Mode decoding for direct part marks, linear and 2D symbols; High Density (SXGA), High Speed (WVGA) and 3 Megapixel (QXGA) options p. 8
Resolution
MINI Hawk 3: 2048 x 1536 (QXGA); HR: 1280 x 1024 (SXGA); HS: 752 x 480 (WVGA) p. 342
Interfaces
USB, RS-232 and RS-422/485 p. 8
Connector
3 ft. cable with High Density 15-pin D-Sub socket or USB Type A connector p. 342
Power
4.0 Watts max.; 5VDC +/– 5%, 200 mV p-p max. ripple, 554 mA at 5VDC (typ.); optional 10-28V accessory p. 346
Size and weight
1" (25.4 mm) high, 1.8" (45.7 mm) wide, 2.10" (53.3 mm) deep; 2 oz. (57 g) p. 342
Focus and speed
Autofocus, focal range 2 to 6” (50.8 to 152.4 mm); up to 10 decodes per second p. 342
Environment
Operating 0° to 40°C (32° to 104°F); storage -50° to 75° C; humidity up to 90% non-condensing; enclosure IP54, category 2 p. 342
Discrete I/O
Trigger and New Master inputs 5 to 28VDC rated (.16 mA); outputs 1, 2, 3 5V TTL compatible; optoisolated I/O with IC-332 accessory p. 342
Setup hardware
Quick start system: MINI Hawk, IC-332 Adapter, IB-131 Interface Box, power supply (90-264 VAC, 24VDC), object detector and communication cable p. 14
Model options
FIS-6300 numbers in 3 Megapixel, High Resolution and High Speed versions, each with RS-232/422/485 or USB + I/O, 5VDC p. 345
Setup software
ESP (Easy Setup Program); needs a 233 MHz Pentium PC, Windows 8, 7, Vista or XP, 128 MB RAM, 160 MB free disk p. 17
Symbologies
Data Matrix (ECC 0-200), Aztec Code, QR Code, Micro QR Code, PDF417, MicroPDF417, GS1 DataBar, Code 39, Code 128, BC412, Interleaved 2 of 5, Pharmacode, UPC/EAN, Codabar, Code 93, Postal p. 342
Indicators
Read performance, power and read status LEDs; green flash for good read; blue target pattern; beeper p. 342

What this manual walks you through

  • Connecting the imager, host, object detector and power through the IB-131 and IC-332 p. 15
  • Positioning the imager and symbol p. 16
  • Installing ESP and selecting the model p. 17, 18
  • Calibrating by EZ Button, ESP or serial command p. 23
  • Testing the read rate p. 24
  • Setting up the EZ Button functions p. 185, 186
  • Reading the read range tables for each model p. 344
  • Wiring the host connector p. 346
  • Wiring an external trigger to 5 volt and 10-28 volt devices p. 368
  • Installing the USB-to-Serial Virtual COM Port Driver p. 369

Good to know

  • A USB model must be connected to the host computer before it is powered on, or it is not recognized. p. 15
  • Connect all cables before applying power, and power down before disconnecting any cable. p. 14
  • Clean the hard-coated window only with 100% isopropyl alcohol. p. 367
  • Do not insulate the stand mount: the bottom panel needs metal-to-metal contact to shed heat. p. 367
  • A 5 volt device used with an IC-332 must be connected as a 10-28 volt device. p. 368

Questions this manual answers

How do I calibrate the Microscan MINI Hawk?

Hold the EZ Button about two seconds until two short beeps, click Calibrate in ESP, or send <@CAL> from a terminal program. p. 23

What power supply does the MINI Hawk need?

A UL-listed direct plug-in power unit marked Class II, rated 5 VDC at 3.5 Watts or more if electrical accessories are used. p. 9

How do I restore the MINI Hawk default configuration from the connector?

Connect pin 8 to ground pin 4 of the 15 pin host connector. p. 346

Can a USB MINI Hawk send serial data?

Yes. The USB-to-Serial Virtual COM Port Driver lets a USB MINI Hawk send serial data on Windows 7, Vista and XP (32-bit) and 2000. p. 369

What does the MINI Hawk EZ Button do?

Holding it until one, two or three beeps locates the symbol, calibrates, or tests the read rate; it can also be set to act as a trigger. p. 22, 23, 24, 185

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. MINI Hawk High Performance Imager User Manual1
    1. About the MINI Hawk High Performance Imager8
    2. MINI Hawk Communications8
    3. Warning and Caution Summary9
    4. Statements of Compliance10
    5. Statement of RoHS Compliance11
    6. 1 Quick Start13
    7. 2 Using ESP27
    8. 3 Communications45
    9. 4 Calibration79
    10. 5 Read Cycle99
    11. 6 Symbologies127
    12. 7 I/O Parameters169
    13. 8 Symbol Quality217
    14. 9 Matchcode233
    15. 10 Camera and IP Setup245
    16. 11 Configuration Database279
    17. 12 Terminal297
    18. 13 Utilities303
    19. 14 Output Format327
    20. Appendices341

From the PDF’s own bookmarks.

The whole text · 38 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 101-10
  2. Pages 11 to 2011-20
  3. Pages 21 to 3021-30
  4. Pages 31 to 4031-40
  5. Pages 41 to 5041-50
  6. Pages 51 to 6051-60
  7. Pages 61 to 7061-70
  8. Pages 71 to 8071-80
  9. Pages 81 to 9081-90
  10. Pages 91 to 10091-100
  11. Pages 101 to 110101-110
  12. Pages 111 to 120111-120
  13. Pages 121 to 130121-130
  14. Pages 131 to 140131-140
  15. Pages 141 to 150141-150
  16. Pages 151 to 160151-160
  17. Pages 161 to 170161-170
  18. Pages 171 to 180171-180
  19. Pages 181 to 190181-190
  20. Pages 191 to 200191-200
  21. Pages 201 to 210201-210
  22. Pages 211 to 220211-220
  23. Pages 221 to 230221-230
  24. Pages 231 to 240231-240
  25. Pages 241 to 250241-250
  26. Pages 251 to 260251-260
  27. Pages 261 to 270261-270
  28. Pages 271 to 280271-280
  29. Pages 281 to 290281-290
  30. Pages 291 to 300291-300
  31. Pages 301 to 310301-310
  32. Pages 311 to 320311-320
  33. Pages 321 to 330321-330
  34. Pages 331 to 340331-340
  35. Pages 341 to 350341-350
  36. Pages 351 to 360351-360
  37. Pages 361 to 370361-370
  38. Pages 371 to 380371-380

The file

Revision and size

RevisionP/N 84-006303-02 Rev D
PublisherOmron Microscan Systems, Inc.
Pages380
PDF5.2 MB
TextText from the PDF itself; pages 1, 347, 348 and 349 are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 380

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 380
Page 2
Page 2of 380
Page 3
Page 3of 380

More documents · 1

For the same models