Page 11
Introduction
Statement of RoHS Compliance All Omron Microscan readers with a ‘G’ suffix in the FIS number are RoHS-Compliant. All compliant readers were converted prior to March 1, 2007. All standard accessories in the Omron Microscan Product Pricing Catalog are RoHS-Compliant except 20-500013-01 and 98-000039-02. These products meet all the requirements of “Directive 2002/95/EC” European Parliament and the Council of the European Union for RoHS compliance. In accordance with the latest requirements, our RoHS-Compliant products and packaging do not contain intentionally added Deca-BDE, Perfluorooctanes (PFOS) or Perfluorooctanic Acid (PFOA) compounds above the maximum trace levels. To view the document stating these requirements, please visit: http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=CELEX:32002L0095:EN:HTML and http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2006:372:0032:0034:EN:PDF
Please contact your sales manager for a complete list of Omron Microscan’s RoHSCompliant products. This declaration is based upon information obtained from sources which Omron Microscan believes to be reliable, and from random sample testing; however, the information is provided without any representation of warranty, expressed or implied, regarding accuracy or correctness. Omron Microscan does not specifically run any analysis on our raw materials or end product to measure for these substances. The information provided in this certification notice is correct to the best of Omron Microscan’s knowledge at the date of publication. This notice is not to be considered a warranty or quality specification. Users are responsible for determining the applicability of any RoHS legislation or regulations based on their individual use of the product. In regards to “RoHS Directive 2011_65_EU” Omron Microscan produces Monitoring and Control Instruments as well as Industrial Monitoring & Control Instruments as defined within the directive. Omron Microscan has developed and is implementing a RoHS2 compliance plan with the intention of bringing all active products listed in our current marketing literature within full compliance as per the directive deadlines. Key milestones for the transition plan are as follows: • Complete internal product audit by July 2014. • Initial “Monitoring and Control Instruments” RoHS2 compliant products available by December 2014 • Initial “Industrial Monitoring & Control Instruments” RoHS2 compliant products available by July 2015 • All new products introduced in 2015 are expected to be WEEE & RoHS2 compliant. Omron Microscan will mark the products with the ‘CE’ marking that complies with the RoHS2 process to acquire ‘CE’ certification per the example given: Example >> Machinery directive + EMC directive + RoHS2 = Declaration of Conformity.
MINI Hawk High Performance Imager User Manual xi
Page 12
Statement of RoHS Compliance xii
MINI Hawk High Performance Imager User Manual
Page 13
1 Quick Start Contents Step 1 Check Hardware................................................................................................................ 1-2 Step 2 Connect the System .......................................................................................................... 1-3 Step 3 Position Imager and Symbol.............................................................................................. 1-4 Step 4 Install ESP ......................................................................................................................... 1-5 Step 5 Select Model...................................................................................................................... 1-6 Step 6 Select Protocol and Connect ............................................................................................. 1-7 Step 7 Locate the Symbol in the Field of View ............................................................................. 1-9 Step 8 Calibrate ......................................................................................................................... 1-11 Step 9 Test Read Rate .............................................................................................................. 1-12 Step 10 Configure the Imager in ESP........................................................................................ 1-13 Step 11 Save Configuration in ESP ........................................................................................... 1-14
This chapter is designed to get your MINI Hawk up and running quickly, using the EZ button or ESP (Easy Setup Program). Following these steps will allow you to get a sense of the imager’s capabilities and to test sample symbols. Detailed setup information for installing the imager into your actual application can be found in the subsequent chapters.
MINI Hawk High Performance Imager User Manual
1-1
Page 14
Check Hardware
Step 1, Check Hardware Item 1 2 3 4 5 6
Description
Part Number FIS-6300-XXXXG FIS-0001-0035G 99-000018-01 97-100004-15 99-000017-01 61-300026-03
MINI Hawk IC-332 Adapter IB-131 Interface Box Power Supply (90-264 VAC, 24VDC, USA/Euro plug) Object Detector Communication Cable
1
2
Host
4
3
Network
Scanner
6
5
Hardware Required
Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.
1-2
MINI Hawk High Performance Imager User Manual
Page 15
Quick Start
Step 2, Connect the System Connecting by RS-232/RS-422/RS-485 • Connect the imager (1) to the IB-131/IC-332 interface (2) and (3). • Connect the host cable (6) to the host and to the host port on the IB-131 (3). • Connect the object detector (5) to the IB-131 (3). • Connect the power supply (4) to the IB-131 (3). • Apply power to the imager. Important: If you are using a USB model, you must connect the device to the host computer before powering-on. Otherwise the unit will not be recognized as a USB device.
1
2
Host
3
4
Network
Scanner
6
5
Hardware Configuration
Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.
MINI Hawk High Performance Imager User Manual
1-3
Page 16
Position Imager and Symbol
Step 3, Position Imager and Symbol • Position the imager at a focal distance between 2 and 6 inches from the symbol. • Tip the imager relative to the symbol to avoid the glare of direct (specular) reflection. The case parting line should be perpendicular to the plane of the symbol by either pitching the symbol or the imager as shown. • Position the imager in a place with as little ambient light as possible. • Symbols can be rotated (tilted) at any angle; however, for best results symbols should be aligned with the FOV (field of view).
Imager and Symbol Orientation • In the case of linear symbols, aligning the bars in the direction of their movement (“ladder” orientation) will minimize the chances of blurring, and will produce better reads. Important: Avoid excessive skew or pitch. Maximum skew is ±30°; maximum pitch is ±30°. The illustration below shows skew axis, pitch axis, and tilt axis. Bar code label axis Skew
Tilt axis Tilt
Symbol Scanner
Reader
Scan line
Pitch Pitch axis
Note: For accuracy of testing and performance, Omron Microscan recommends using a mounting arm adapter kit. Contact your Omron Microscan sales manager for details about mounting arm adapter kits and other accessories. 1-4
MINI Hawk High Performance Imager User Manual
Page 17
Quick Start
Step 4, Install ESP ESP Software can be found on the Omron Microscan Tools Drive that is packaged with the reader. 1. Follow the prompts to install ESP from the Tools Drive. 2. Click on the ESP icon to run the program.
Note: ESP can also be installed from the Download Center at www.microscan.com.
Minimum System Requirements • 233 MHz Pentium PC • Windows 8, 7, Vista, or XP operating system (32-bit or 64-bit) • Internet Explorer 6.0 or higher • 128 MB RAM or greater • 160 MB free disk space • 800 x 600 256 color display (1024 x 768 32-bit color recommended)
MINI Hawk High Performance Imager User Manual
1-5
Page 18
Select Model
Step 5, Select Model When you start ESP, the following menu will appear:
1. Click the button showing the MINI Hawk. 2. Click OK. Note: You can also double-click the MINI Hawk button to make your selection. 3. Click Yes when this dialog appears:
Note: If you need to select another model later, click the Switch Model button near the top of the screen or use Model > New Model in the menu toolbar.
1-6
MINI Hawk High Performance Imager User Manual
Page 19
Quick Start
Step 6, Select Protocol and Connect • Choose the connection protocol you are using and click Connect.
• Once you select your communications mode, follow the simple prompts to establish your connection.
MINI Hawk High Performance Imager User Manual
1-7
Page 20
Select Protocol and Connect (cont.)
Step 6, Select Protocol and Connect (cont.) When you are connected, you will see the green connection indicator in the status bar at the bottom right of your screen. RS-232: USB: • If your RS-232 connection attempt fails, click the Autoconnect button, select a different communications port, and try again. Note: If your RS-232 host settings cannot be changed to match the imager’s settings, check the Force Connect box in the RS-232 dialog and click the Connect.
1-8
MINI Hawk High Performance Imager User Manual