Page 141

Symbologies

BC412 Usage: Definition:

Serial Cmd: Default: Options:

Widely used in semiconductor manufacturing. Particularly useful where speed, accuracy, and ease of printing are required. BC412 (Binary Code 412), a proprietary IBM symbology since 1988, is an alphanumeric symbol with a set of 35 characters, each encoded by a set of 4 bars in 12 module positions. All bars have a single width; it is the presence (1) or absence (0) of bars in each of the twelve module positions that make BC412 binary. This symbology is also bi-directional and self-clocking, with a start character and a stop character. <K481,status,check character output,fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled

Check Character Output (BC412) Usage: Definition: Serial Cmd: Default: Options:

Check Character Output, added to the symbol, provides additional security. When enabled, the check character character is read and compared along with the symbol data. When disabled, symbol data is sent without the check character. <K481,status,check character output,fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length Status (BC412) Definition: Serial Cmd: Default: Options:

When enabled, the imager will check the symbol length against the symbol length field. If disabled, any length will be considered valid. <K481,status,check character output,fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length (BC412) Definition: Serial Cmd: Default: Options:

When enabled, the check character character is read and compared along with the symbol data. When disabled, symbol data is sent without the check character. <K481,status,check character output,fixed symbol length status,fixed symbol length> 10 1 to 64

MINI Hawk High Performance Imager User Manual

6-15

Page 142

Interleaved 2 of 5

Interleaved 2 of 5 Usage:

Definition:

Serial Cmd: Default: Options:

I-2/5 has been popular because it is the most dense symbology for printing numeric characters less than 10 characters in length; however, Omron Microscan does not recommend this symbology for any new applications because of inherent problems such as truncation. A dense, contimuous, self-checking, numeric symbology. Characters are paired together so that each character has five elements, two wide and three narrow, representing numbers 0 through 9, with the bars representing the first character and the interleaved spaces representing the second character. (A check character is highly recommended). Important: You must set Symbol Length in order to decode I-2/5 symbols, unless Range Mode is enabled. <K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> Enabled 0 = Disabled 1 = Enabled

Check Character Status (Interleaved 2 of 5) Usage: Definition: Serial Cmd: Default: Options:

This option is not typically used, but it can be enabled for additional security in applications where the host requires redundant check character verification. An error correcting routine in which the check character character is added. <K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> Disabled 0 = Disabled 1 = Enabled

Check Character Output Status (Interleaved 2 of 5) Definition: Serial Cmd: Default: Options:

6-16

When enabled, a check character character is sent along with the symbol data for added data security. <K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> Disabled 0 = Disabled 1 = Enabled

MINI Hawk High Performance Imager User Manual

Page 143

Symbologies

Symbol Length #1 (Interleaved 2 of 5) Usage: Definition: Serial Cmd: Default: Options:

Useful in applications where I 2/5 symbols of a specific length are required. The Symbol Length # 1 field is one of two fields against which the decoded symbol is compared before accepting it as valid or rejecting it. <K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 16 0 to 64, even only Important: If Range Mode is disabled, the length of the symbol must match either Symbol Length # 1 or Symbol Length # 2 to be considered a valid symbol. If Range Mode is enabled, Symbol Length # 1 and Symbol Length # 2 form a range into which the length of the symbol must fall to be considered valid.

Symbol Length #2 (Interleaved 2 of 5) Usage: Definition: Serial Cmd: Default: Options:

Useful in applications where I 2/5 symbols of a specific length are required. The Symbol Length # 2 field is one of two fields against which the decoded symbol is compared before accepting it as valid or rejecting it. <K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 6 0 to 64, even only Important: If Range Mode is disabled, the length of the symbol must match either Symbol Length # 2 or Symbol Length # 1 to be considered a valid symbol. If Range Mode is enabled, Symbol Length # 2 and Symbol Length # 1 form a range into which the length of the symbol must fall to be considered valid.

MINI Hawk High Performance Imager User Manual

6-17

Page 144

Interleaved 2 of 5

Guard Bar Status (Interleaved 2 of 5) Note: Whenever Guard Bar is enabled, the presence of guard bars (also called “bearer bars”) is required for decoding to take place. Usage: Definition: Serial Cmd: Default: Options:

Useful when I-2/5 multisymbols are enabled to prevent false data output. This typically occurs with highly tilted or skewed symbols. A guard bar is a heavy bar, at least twice the width of the wide bar, surrounding the printed I-2/5 symbol and helping to prevent false reads. <K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> Disabled 0 = Disabled 1 = Enabled

Range Mode Status (Interleaved 2 of 5) Usage: Definition:

Serial Cmd: Default: Options:

6-18

Useful in applications where I 2/5 symbols of a specific length are required. When Range Mode is disabled, the imager checks the value of the symbol length against the values set in Symbol Length # 1 and Symbol Length # 2. If the symbol length does not match either of the preset values, then it is rejected as invalid. When Range Mode is enabled, Symbol Length # 1 and Symbol Length # 2 are combined to form a range of valid symbol lengths. Any symbol length that does not fall into this range is rejected as an invalid symbol. Either of the preset symbol length values in the Symbol Length # 1 and Symbol Length # 2 fields can form the start or end of the range. <K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> Enabled 0 = Disabled 1 = Enabled

MINI Hawk High Performance Imager User Manual

Page 145

Symbologies

Code 93 Usage: Definition: Serial Cmd: Default: Options:

Sometimes used in clinical applications. Code 93 is a variable-length, continuous symbology employing four element widths. Each Code 93 character has nine modules that may be either black or white. Each character contains three bars and three spaces. <K475,status,fixed symbol length status,symbol length> Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length Status (Code 93) Definition:

Serial Cmd: Default: Options:

When disabled, the imager will accept any Code 93 symbol provided is doesn’t exceed the system’s maximum capabilities. When enabled, the imager will reject any Code 93 symbol that doesn’t match the fixed symbol length. <K475,status,fixed symbol length status,symbol length> Disabled 0 = Disabled 1 = Enabled

Symbol Length (Code 93) Definition: Serial Cmd: Default: Options:

This is the symbol length value against which all Code 93 symbols will be compared. <K475,status,fixed symbol length status,symbol length> 10 1 to 64

MINI Hawk High Performance Imager User Manual

6-19

Page 146

Codabar

Codabar Usage: Definition: Serial Cmd: Default: Options:

Used in photo-finishing and library applications. Previously used in medical applications, but not typically used in newer medical applications. Codabar is a 16-bit character set (0 through 9, and the characters $, :, /, ., +, and –) with start/stop codes and at least two distinctly different bar widths. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> Disabled 0 = Disabled 1 = Enabled

Start/Stop Match (Codabar) Definition:

Serial Cmd: Default: Options:

When disabled, the imager will decode Codabar symbols whether or not the start and stop characters are the same. When enabled, the imager will not decode Codabar symbols unless the start and stop characters are the same. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> Enabled 0 = Disabled 1 = Enabled

Start/Stop Output (Codabar) Definition:

Serial Cmd: Default: Options:

6-20

When disabled, the start and stop characters will not be present in the data output of the decoded symbol. When enabled, the start and stop characters will be present in the data output of the decoded symbol. Note: Because the start and stop characters are included as part of the data, the characters must be included as part of the length in a fixed length mode of operation. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> Enabled 0 = Disabled 1 = Enabled

MINI Hawk High Performance Imager User Manual

Page 147

Symbologies

Large Intercharacter Gap (Codabar) Definition:

Serial Cmd: Default: Options:

When disabled, the spaces between characters, or the “intercharacter gap”, are ignored during the decode process. Note: If the intercharacter space is large enough to be considered a margin, the symbol will not decode, regardless of this parameter’s setting. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length Status (Codabar) Definition:

Serial Cmd: Default: Options:

When disabled, the imager will accept any Codabar symbol provided it doesn’t exceed the system’s maximum capabilities. When enabled, the imager will reject any Codabar symbol that doesn’t match the fixed length. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> Disabled 0 = Disabled 1 = Enabled

Symbol Length (Codabar) Definition: Serial Cmd: Default: Options:

This is the value against which all Codabar symbol lengths will be compared. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 10 1 to 64

MINI Hawk High Performance Imager User Manual

6-21

Page 148

Codabar

Check Character Type (Codabar) Definition:

Serial Cmd: Default: Options:

When disabled, the imager will not perform any character checking calculations on decoded Codabar symbols. When set to Mod 16, the imager will perform a modulus 16 check character calculation on the symbol. If the symbol does not pass this calculation, it will not be decoded. When set to NW7, The imager will perform an NW7 modulus 11 check character calculation on the symbol. If the symbol does not pass this calculation, it will not be decoded. When set to Both, the imager will perform both the Mod 16 and NW7 modulus 11 check character calculations on the symbol. If the symbol does not pass either calculation, it will not be decoded. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> Disabled 0 = Disabled 1 = Mod 16 2 = NW7 (Mod 11) 3 = Mod 16 and NW7

Check Character Output (Codabar) Definition:

Serial Cmd: Default: Options:

6-22

When this field is disabled and a check character calculation is enabled, the imager will strip the verified check character from the symbol data output. This condition must be accounted for if a fixed length is also being used. When enabled, the imager will output the check character as part of the symbol data. This condition must be accounted for if a fixed length is also being used. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> Disabled 0 = Disabled 1 = Enabled

MINI Hawk High Performance Imager User Manual

Page 149

Symbologies

UPC/EAN Usage:

Definition:

Serial Cmd: Default: Options:

Used primarily in point-of-sale applications in the retail industry. It is commonly used with Omron Microscan readers in applications in combination with Matchcode when there is a need to verify that the right product is being placed in the right packaging. UPC (Universal Product Code) is a fixed length, numeric, continuous symbology. UPC can have two- or five-digit supplemental bar code data following the normal code. The UPC Version A (UPC, A) symbol is used to encode a 12 digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character. When enabled, the imager will read UPC Version A and UPC Version E only. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Enabled 0 = Disabled 1 = Enabled

EAN Status Usage: Definition:

Serial Cmd: Default: Options:

EAN is the European version of the UPC symbology and is used in European market applications. Note: UPC must be enabled for EAN to take effect. EAN is a subset of UPC. When enabled, the imager will read UPC Version A, UPC Version E, EAN 13, and EAN 8. It also appends a leading zero to UPC Version A symbol information and transmits 13 digits. If transmitting 13 digits when reading UPC Version A symbols is not desired, disable EAN. Note: The extra character identifies the country of origin. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Enabled 0 = Disabled 1 = Enabled

MINI Hawk High Performance Imager User Manual

6-23

Page 150

UPC/EAN

Supplementals Status (UPC/EAN) Usage: Definition: Serial Cmd: Default: Options:

Reads Supplementals typically used in publications and documentation. A supplemental is a 2 to 5 digit symbol appended to the main symbol. When set to Enabled or Required, the imager reads supplemental code data that has been appended to the standard UPC or EAN codes. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled 1 = Enabled 2 = Required

Disabled UPC Supplementals will not be decoded.

Enabled When enabled, the imager will try to decode a main and a supplemental. However, if a supplemental is not decoded, the main will be sent by itself at the end of the read cycle.

Required When set to Required, both the main and the supplemental symbols must be read or a single No Read condition results. For example, if Supplementals is set to Required, Separator is enabled, and an asterisk is defined as the UPC separator character. Then the data is displayed as: MAIN * SUPPLEMENTAL. Note: Under no circumstances will the supplemental symbol data be sent without a main symbol. Note: If additional symbols - other than the main or supplemental - will be read in the same read cycle, Number of Symbols should be set accordingly.

Separator Status (UPC/EAN) Usage: Definition: Serial Cmd: Default: Options:

6-24

Allows users to distinguish between the main and Supplemental symbols. A character can be inserted between the standard UPC or EAN symbology and the supplemental symbology when Supplementals is set to Enabled or Required. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled 1 = Enabled

MINI Hawk High Performance Imager User Manual