The text of a manual · part 21 of 38
MINI Hawk High Performance Imager User Manual, pages 201 to 210
Pages 201 to 210 of 380
The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan Mini Hawk
Page 201
I/O Parameters
Power On/Reset Counts Note: Power On/Reset Counts is a read-only command.
Power-On Serial Cmd:
<K406,power-on,resets,power-on saves,power-on flash saves>
Power-On uses a 16-bit counter that increments each time the imager is powered-on.
Resets Serial Cmd:
<K406,power-on,resets,power-on saves,power-on flash saves>
Resets uses a 16-bit counter that increments each time the imager is reset. This value is reset at power-on.
Power-On Saves Serial Cmd:
<K406,power-on,resets,power-on saves,power-on flash saves>
Power-On Saves uses a 16-bit counter that increments each time an imager setting is saved for power-on with a <Z> command.
Power-On Flash Saves Serial Cmd:
<K406,power-on,resets,power-on saves,power-on flash saves>
Power-On Flash Saves uses a 16-bit counter that increments each time an imager setting is saved to the customer parameter section of flash memory with a <Zc> command.
MINI Hawk High Performance Imager User Manual
7-33
Page 202
Time Since Reset
Time Since Reset Note: Time Since Reset is a read-only command.
Hours Serial Cmd: Default:
<K407,hours,minutes> 16-bit counter (0 to 65535)
Hours uses a 16-bit counter that increments every 60 minutes.
Minutes Serial Cmd: Default:
<K407,hours,minutes> 16-bit counter (0 to 60)
Minutes uses a 16-bit counter that increments every 60 seconds. Note: Time counts are reset at power-on, but not with an <A> or <Z> command.
7-34
MINI Hawk High Performance Imager User Manual
Page 203
I/O Parameters
Service Message When Service Message is enabled, a message of up to 10 ASCII characters is sent whenever the system detects that the service timer’s limit has been reached. The service timer is reset at power-on, meaning that the service timer’s limit is the amount of time since last reset. Service timer increments can be set in seconds or minutes. Serial Cmd: Default: Options:
<K409,status,service message,threshold,resolution> 0 0 = Disabled 1 = Enabled
Service Message Serial Cmd: Default: Options:
<K409,status,service message,threshold,resolution> SERVICE An ASCII string between 1 and 10 characters.
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K409h,,3C> For >: <K409h,,3E> For , : <K409h,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.
Threshold Serial Cmd: Default: Options:
<K409,status,service message,threshold,resolution> 300 (5 minutes) 1 to 65535
Resolution Serial Cmd: Default: Options:
<K409,status,service message,threshold,resolution> Seconds 0 = Seconds 1 = Minutes
MINI Hawk High Performance Imager User Manual
7-35
Page 204
Frame Information
Frame Information Output Frame Number Serial Cmd: <K734,output frame number,output coordinates> Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Disabled When Output Frame Number is set to Disabled, the frame number is not output as part of the symbol data.
Enabled When Output Frame Number is set to Enabled, the number of the frame in which the symbol was first decoded is attached to the symbol output information. The output format is “Fnnn”, where “nnn” is a 3-digit decimal value from 0 to 255. The frame number rolls over to 0 once it passes 255. If this feature is enabled, the frame information will follow the symbol data, and it will precede any symbol quality data (if symbol quality settings are enabled - see Symbol Quality Separator on page 8-8). The symbol quality separator is located between the end of the already-formatted data and the “F” that precedes the frame number.
Output Coordinates Serial Cmd: <K734,output frame number,output coordinates> Default:
Disabled
Options:
0 = Disabled
1 = Enabled
Disabled When Output Coordinates is set to Disabled, the coordinates are not output as part of the symbol data.
Enabled When Output Coordinates is set to Enabled, the four sets of object coordinates for the first successfully decoded symbol are attached to the symbol data output in the following format: “(nnn,mmm)”, where “nnn” is a 3-digit X-coordinate and “mmm” is a 3-digit Y-coordinate. The validation separator is located between the end of the already formatted data and the first coordinate point. The point with the lowest X + Y sum will be output first, followed by the next three points in a clockwise direction. Example: (032,040)(287,056)(287,279)(048,271)
7-36
MINI Hawk High Performance Imager User Manual
Page 205
I/O Parameters
Image Output Usage: Definition:
Serial Cmd: Default: Options:
This feature allows the user to select what read cycle condition triggers the image file output. Used to output an image file when a specified read cycle condition has been met, such as No Read or Good Read. When the read cycle is complete, the normal read cycle output will occur, including any configured postamble or preamble data. The read cycle will the check if image output is enabled, and if the specified read cycle condition has been met. If both these conditions are true, the image file will be output to the user-specified communication port in the user-specified image file format. <K739,image output mode,communication port,file format,JPEG quality> Disabled 0 = Disabled 1 = Good Read 2 = No Read 3 = No Read or Good Read 4 = Mismatch
Good Read If a Good Read condition is met during the read cycle, the image file corresponding with the first Good Read will be output. The image file will immediately follow the read cycle output and postambles. For a Good Read condition to occur, all symbols in the read cycle must qualify.
No Read If a No Read condition occurs during the read cycle, the image file corresponding with the first No Read will output. The image file will immediately follow the read cycle output and postambles. There are conditions in which the read cycle may have a No Read condition but the image will not be output. For example, if the read cycle is looking for two No Read symbols in the same image capture but one is a Good Read, the image will not be output, because it is not considered a No Read image.
No Read or Good Read If a No Read condition or a Good Read condition occurs, the first image of either kind will be output.
Mismatch If a Good Read occurs during the read cycle but the image is a Mismatch condition, the first Mismatch image will be output.
MINI Hawk High Performance Imager User Manual
7-37
Page 206
Image Output
Communication Port Definition: Serial Cmd: Default: Options:
This setting selects the communication port through which the image file will be transferred to the host. <K739,image output mode,communication port,file format,JPEG quality> Host 0 = Host 1 = Auxiliary 2 = USB
File Format Definition:
Serial Cmd: Default: Options:
This setting selects the format of the image file to be output. Note: If JPEG is the chosen image file format, the resolution of the image will be determined by the setting in the JPEG Quality field. <K739,image output mode,communication port,file format,JPEG quality> JPEG 0 = Bitmap 1 = JPEG 2 = Binary
JPEG Quality Definition: Serial Cmd: Default: Options:
7-38
This setting determines the quality of JPEG image compression. The user may select a value from 1 (lowest) to 100 (highest). <K739,image output mode,communication port,file format,JPEG quality> 90 1 to 100 (percent)
MINI Hawk High Performance Imager User Manual
Page 207
I/O Parameters
Image Output Example The following example assumes that the imager is set to output on No Read, and that it is in a rapid capture mode of 3 captures. Number of Symbols: Frame # 1: Frame # 2: Frame # 3: Read Cycle Result: Output Frame:
1 No Read No Read No Read No Read Frame # 1
Number of Symbols: Frame # 1: Frame # 2: Frame # 3: Read Cycle Result: Output Frame:
1 No Read No Read Good Read Good Read None
Number of Symbols: Frame # 1: Frame # 2: Frame # 3: Read Cycle Result: Output Frame:
2 No Read No Read Good Read, Symbol # 1 No Read Frame # 1
MINI Hawk High Performance Imager User Manual
7-39
Page 208
Database Identifier Output
Database Identifier Output Usage: Serial Cmd: Default: Options:
Useful in keeping track of which database entries read which symbols. <K759,status,separator> 0 0 = Disabled 1 = Enabled
Output Status Disabled When this command is disabled, no database identifier information will be output.
Enabled When this command is enabled, the imager will append a two-digit number and the characters “DB” to the data output following the separator for each symbol decoded using Configuration Database. For example, if the separator is an underscore character and the second database entry reads a symbol encoded with “data capture” during the read cycle, the symbol data output will be “data capture_DB02”. If the database is not active, no identifiers will be attached to output.
Separator Usage: Serial Cmd: Default: Options:
The separator character separates the symbol data from the database identifier. <K759,status,separator> <space> Any ASCII character.
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K759h,,3C> For >: <K759h,,3E> For , : <K759h,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.
7-40
MINI Hawk High Performance Imager User Manual
Page 209
I/O Parameters
Quality Output Separator Definition: Serial Cmd: Default: Options:
The separator character separates quality output data from symbol data. <K704,separator,decodes per trigger status> , Any ASCII character.
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K704h,3C> For >: <K704h,3E> For , : <K704h,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.
Decodes per Trigger Status Definition:
Serial Cmd: Default: Options:
When this feature is enabled, the imager enters a state where it processes frames as configured until the end of a read cycle, with or without a successful symbol decode. When the read cycle ends, the imager outputs any decoded symbol data along with the decodes per trigger count. <K704,separator,decodes per trigger status> 0 0 = Disabled 1 = Enabled
MINI Hawk High Performance Imager User Manual
7-41
Page 210
Configuring EZ Trax Output
Configuring EZ Trax Output After you have set up your imager for EZ Trax, you can configure the software in three different ways: using the EZ Trax interface, using the tree controls in ESP, and using serial commands. For detailed information about how to use the EZ Trax user interface for configuration, refer to the Help menu in EZ Trax software, or the EZ Trax Quick Start Guide, available on the Omron Microscan Tools Drive.
Configuring EZ Trax Output by ESP To configure EZ Trax using ESP, first click the I/O tab in App Mode to display the I/O Parameters tree control.
7-42
MINI Hawk High Performance Imager User Manual