The text of a manual · part 24 of 38
MINI Hawk High Performance Imager User Manual, pages 231 to 240
Pages 231 to 240 of 380
The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan Mini Hawk
Page 231
Symbol Quality
Quiet Zone (Data Matrix Only) Definition: Serial Cmd: Default: Options:
When this feature is enabled, the size of the quiet zone is evaluated and a PASS or FAIL message is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
Symbol Angle (Data Matrix Only) Definition: Serial Cmd: Default: Options:
When this feature is enabled, the symbol orientation is appended to data output as a degree value representing the angle of the Data Matrix symbol’s L-shaped finder pattern relative to the imager. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
MINI Hawk High Performance Imager User Manual
8-15
Page 232
Omron Microscan Symbol Quality Output by ESP
Omron Microscan Symbol Quality Output by ESP ESP’s Symbol Quality interface allows you to evaluate Data Matrix symbols for compliance with a rigorous set of standards, such as Locate Time, Capture Time, and Decode Time. First, determine which parameters you want to evaluate, using the Symbol Quality tree control.
Once you have set these Data Matrix evaluation parameters, go to the Preferences Tab and set your Data Matrix Grading Report output preferences.
After your output preferences are set, click the Data Matrix Grading button.
There will be a wait of a few seconds, and then the evaluation results will appear in the Symbol Quality view, in a format similar to the one shown below.
If you want to view the results in a report format, click the Save Report button. The report will be output in the format you chose in the Preferences dialog.
8-16
MINI Hawk High Performance Imager User Manual
Page 233
9 Matchcode Contents Matchcode by ESP ....................................................................................................................... 9-2 Matchcode Serial Commands ...................................................................................................... 9-3 Overview of Matchcode ................................................................................................................ 9-4 Matchcode Type ........................................................................................................................... 9-5 Match Replace............................................................................................................................ 9-10 Mismatch Replace ...................................................................................................................... 9-11 New Master Pin .......................................................................................................................... 9-12
This section explains the MINI Hawk’s matchcode output functions and the master symbol database setup.
MINI Hawk High Performance Imager User Manual
9-1
Page 234
Matchcode by ESP
Matchcode by ESP
Click the Parameters button and then the Matchcode tab.
To open nested options, single-click the +.
9-2
To change a setting, double-click the setting and use your cursor to scroll through the options.
MINI Hawk High Performance Imager User Manual
Page 235
Matchcode
Matchcode Serial Commands Matchcode Type Number of Master Symbols New Master Pin Enter Master Symbol Data Request Master Symbol Data Delete Master Symbol Data Match Replace Mismatch Replace
<K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> <K224,number of master symbols> <K225,status> <K231,master symbol number,master symbol data> <K231?,>[for all] or <K231?,master symbol number> <K231,master symbol number,> <K735,status,match replacement string> <K736,status,mismatch replacement string>
MINI Hawk High Performance Imager User Manual
9-3
Page 236
Overview of Matchcode
Overview of Matchcode Definition:
Usage:
Matchcode allows the user to store master symbol data in the imager’s memory, compare that data against other symbol data, and define how symbol data and/or discrete signal output will be directed. A master symbol database can be set up for up to 10 master symbols. Note: Matchcode will function with multiple symbols; however, if Matchcode Type is set to Sequential or if Triggering Mode is set to Continuous Read 1 Output, the imager will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration. Matchcode is used in applications to sort, route, or verify data based on matching the specific symbol in a variety of ways as defined in this section. For example, a manufacturer might sort a product based on dates that are embedded in the symbol.
Steps for Entering and Using Master Symbols 1. Set Triggering Mode to External or Serial. 2. Choose the method of symbol comparison that fits your application. 3. Define the output you want to achieve with your matchcode setup: a. Symbol data output b. Discrete output 4. Select the number of master symbols you want to create. 5. Decide which of 4 ways you want to enter your master symbol(s): a. Use ESP to type master symbol data directly. b. Send a serial command with symbol data in the form of <M231,master symbol#, data>. c. Send a <G> (Read Next Symbol as Master Symbol) command. d. Enable the New Master Pin command and activate the discrete input to store the next symbol read as the master symbol.
9-4
MINI Hawk High Performance Imager User Manual
Page 237
Matchcode
Matchcode Type Definition:
Allows the user to choose the way that master symbols will be compared with subsequently read symbols. Note: First set Triggering Mode to External or Serial.
ESP:
Serial Cmd: Default: Options:
Disabled: Enabled: Wild Card: Sequential:
<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on No Read,sequence on mismatch> Disabled 0 = Disabled 1 = Enabled 2 = Wild Card 3 = Sequential Has no effect on operations. Instructs the imager to compare symbols or portions of symbols with the master symbol. Allows the user to enter user-defined wild card characters in the master symbol. Instructs the imager to sequence after each match (numeric only) and compare symbols or portions of symbols for sequential numbers. Note: If Matchcode Type is set to Sequential, the imager will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration.
MINI Hawk High Performance Imager User Manual
9-5
Page 238
Matchcode Type
Sequential Matching Usage: Definition: Serial Cmd: Default: Options:
Useful in tracking product serial numbers that increment or decrement sequentially. With Sequential enabled, Sequential Matching determines if a count is in ascending (incremental) or descending (decremental) order. <K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> Increment 0 = Increment 1 = Decrement
Match Start Position Usage:
Match Start Position is useful in defining specific portions of a symbol for comparison. For example, if a symbol contains a part number, manufacturing date, and lot code info, but you are only interested in the part number information, you can set the imager to sort only the part number and ignore the other characters. Definition: Match Start Position determines the portions of symbols that will be matched by defining the first character in the symbol (from left to right) that will be compared with those of the master symbol, when Matchcode Type is set to Enabled or Sequential. Function: For example, if Match Start Position is set to 3, the first 2 characters read in the symbol will be ignored and only the 3rd and subsequent characters to the right will be compared, up to the number of characters specified by Match Length. Serial Cmd: <K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on No Read,sequence on mismatch> Default: 0 Options: 0 to 3000 Note: Match Start Position must be set to 1 or greater to enable this feature. A 0 setting will disable this feature.
Match Length Usage: Definition: Serial Cmd: Default: Options: 9-6
Example: If Match Length is set to 6 in a 10-character symbol, and Match Start Position is set to 2, only the 2nd through 7th characters (from left to right) will be compared. Defines the length of the character string that will be compared with that of the master symbol when Match Start Position is set to 1 or greater. When Match Start Position is set to 0, no comparison will occur. <K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> 1 1 to 3000 MINI Hawk High Performance Imager User Manual
Page 239
Matchcode
Wild Card Character Usage:
Definition: Serial Cmd: Default: Options:
Example: With Wild Card Character defined as the default asterisk, defining CR*34 as the master symbol will result in matches for CR134 and CR234, but not CR2345. Entering URGENT** as your master symbol will result in matches for URGENT, URGENT1, and URGENT12 but not for URGENT123. This means any wild cards appended to the master symbol data will result in matches of symbols in variable lengths up to the master symbol lengths but not over. However, wild cards in the beginning or center of a symbol (e.g., UR**NT) do not allow for variable symbol lengths. Wild Card Character allows a user to define a wild card character as part of the master symbol. <K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> * (asterisk) Any ASCII character.
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K223h,,,,,3C> For >: <K223h,,,,,3E> For , : <K223h,,,,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.
MINI Hawk High Performance Imager User Manual
9-7
Page 240
Matchcode Type
Sequence on No Read Usage: Definition: Serial Cmd: Default: Options:
Sequence on No Read is useful when the imager needs to stay in sequence even if no decode occurs. When Sequence on No Read is Enabled and Matchcode is set to Sequential, the imager sequences the master symbol on every match or No Read. When disabled, it does not sequence on a No Read. <K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> Enabled 0 = Disabled 1 = Enabled
As an example of Sequence on No Read Enabled, consider the following decodes: Master Symbol 001 002 003 004 005 006 007
Decoded Symbol 001 002 No Read 004 No Read No Read 007
Master Symbol after Decode 002 003 004 (sequenced on No Read) 005 006 (sequenced on No Read) 007 (sequenced on No Read) 008
As an example of Sequence on No Read Disabled, consider the following series of decodes: Master Symbol 001 002 003 003 004 004 004
9-8
Decoded Symbol 001 002 No Read 003 No Read No Read 004
Master Symbol after Decode 002 003 003 (not sequenced) 004 004 (not sequenced) 004 (not sequenced) 005
MINI Hawk High Performance Imager User Manual