For the Microscan Mini Hawk

Page 241

Matchcode

Sequence on Mismatch Note: Matchcode must be set to Sequential for this command to function. Usage:

Definition:

Serial Cmd: Default: Options:

Enable this parameter if every trigger event should have a decode and more than one consecutive mismatch may occur. Disable this parameter if every trigger event should have a decode but no more than one consecutive mismatch may occur. When set to Enabled, the master symbol sequences on every decode, match, or mismatch. When set to Disabled, the master symbol will not sequence whenever consecutive mismatches occur. <K223,matchcode type,sequential matching,match start position,match length,wild card character,sequence on No Read,sequence on mismatch> Disabled 0 = Disabled 1 = Enabled

The imager will sequence the master to one more or one less than the decoded symbol. As an example of Sequence on Mismatch Enabled, consider the following decodes: Master Symbol 001 002 003 004 005 006 007

Decoded Symbol 001 002 abc 004 def ghi 007

Master Symbol after Decode 002 003 004 (sequenced on mismatch) 005 006 (sequenced on mismatch) 007 (sequenced on mismatch) 008

As an example of Sequence on Mismatch Disabled, consider the following decodes: Master Symbol 001 002 003 004 005 006 006

Decoded Symbol 001 002 abc 004 def ghi 006

MINI Hawk High Performance Imager User Manual

Master Symbol after Decode 002 003 004 (sequenced because of previous match) 005 006 (sequenced because of previous match) 006 (not sequenced) 007

9-9

Page 242

Match Replace

Match Replace Usage: Definition: Serial Cmd: Default: Options:

Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol matches a master symbol. Outputs a user-defined data string whenever a match occurs and Matchcode is enabled. <K735,status,replacement string> Disabled 0 = Disabled 1 = Enabled

Replacement String Definition: Serial Cmd: Default: Options:

User-defined data string that, when enabled, replaces symbol data whenever a match occurs. <K735,status,replacement string> MATCH An ASCII string up to 64 characters.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K735h,,3C> For >: <K735h,,3E> For , : <K735h,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.

9-10

MINI Hawk High Performance Imager User Manual

Page 243

Matchcode

Mismatch Replace Usage: Definition: Serial Cmd: Default: Options:

Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol does not match a master symbol. Outputs a user-defined data string whenever a mismatch occurs and Matchcode is enabled. <K736,status,replacement string> Disabled 0 = Disabled 1 = Enabled

Replacement String Definition: Serial Cmd: Default: Options:

User-defined data string that, when enabled, replaces symbol data whenever a mismatch occurs. <K736,status,replacement string> MISMATCH An ASCII string up to 64 characters.

Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K736h,,3C> For >: <K736h,,3E> For , : <K736h,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.

MINI Hawk High Performance Imager User Manual

9-11

Page 244

New Master Pin

New Master Pin Definition:

Serial Cmd: Default: Options:

If Matchcode and New Master Pin are enabled and the new master pin is momentarily connected to ground (must be held low for a minimum of 10 ms) master symbol information will be loaded into the database based on the next read cycle that achieves a Good Read, starting with Index 1. The Master Symbol Database will be loaded with all symbols decoded in the read cycle as long as it does not exceed the Number of Master Symbols parameter. <K225,status> Disabled 0 = Disabled 1 = Enabled

New Master Load Status Definition:

Serial Cmd:

9-12

The new master status responds with the number of the next master position to be loaded, where 0 represents “idle” or “no master to be loaded.” Example: If the user has the Number of Master Symbols set to 1, and then either sends a <G> or toggles an active New Master Pin, the state will be 1, and prior to reading and effectively loading position 1, the response to <NEWM> would be <NEWM/1>. Once a symbol has been read and loaded, the status will be cleared: <NEWM/0>. <NEWM>

MINI Hawk High Performance Imager User Manual

Page 245

10 Camera and IP Setup Contents Camera and IP Setup by ESP .................................................................................................... 10-2 Camera and IP Setup Serial Commands.................................................................................... 10-3 Video........................................................................................................................................... 10-4 Evaluation ................................................................................................................................... 10-5 Calibration................................................................................................................................... 10-8 Window of Interest ...................................................................................................................... 10-9 Configuration Database ............................................................................................................ 10-13 Dynamic Setup ......................................................................................................................... 10-14 X-Mode™.................................................................................................................................. 10-15 Pixel Sub-Sampling .................................................................................................................. 10-16 Camera Settings ....................................................................................................................... 10-18 Camera Settings (3 Megapixel) ................................................................................................ 10-19 Focal Distance .......................................................................................................................... 10-20 Focal Distance (3 Megapixel) ................................................................................................... 10-21 Focal Distance Table (Read-Only) ........................................................................................... 10-22 Focal Distance Table (Read-Only) (3 Megapixel)..................................................................... 10-23 Increment Focus Position ......................................................................................................... 10-24 Decrement Focus Position........................................................................................................ 10-24 Increment Focus Position (3 Megapixel) .................................................................................. 10-25 Decrement Focus Position (3 Megapixel)................................................................................. 10-25 Illumination Brightness.............................................................................................................. 10-26 Color Filter ................................................................................................................................ 10-27 Skew Correction ....................................................................................................................... 10-28 Morphological Pre-Processing.................................................................................................. 10-31 Morphological Operation and Operator Size ............................................................................ 10-32

This section provides adjustment parameters for the physical controls of the camera, image acquisition, database settings, and image diagnostics.

MINI Hawk High Performance Imager User Manual

10-1

Page 246

Camera and IP Setup by ESP

Camera and IP Setup by ESP

Click the Setup button to bring up the Camera Setup menu.

To change a setting, double-click the setting and use your cursor to scroll through the options.

To open nested options, single-click the +.

10-2

MINI Hawk High Performance Imager User Manual

Page 247

Camera and IP Setup

Camera and IP Setup Serial Commands Window of Interest Focal Distance Increment Focus Position Decrement Focus Position Focal Distance Table (Read-Only) Illumination Brightness Skew Correction Camera Pixel Sub-Sampling Morphological Pre-Processing Morphological Operation

<K516,row pointer,column pointer,row depth,column width> <K525,focal distance> <K525+> <K525–> <K526,number of focal distances,focal distance> <K536,brightness> <K537,line speed,symbol direction> <K541,shutter speed,gain> <K542,pixel sub-sampling,AEC/AGC mode,AEC/AGC brightness> <K550,morphological pre-processing> <K551,0,morphological operation,operator size>

MINI Hawk High Performance Imager User Manual

10-3

Page 248

Video

Video The Video view is similar to the EZ Mode interface, in that the user has the ability to perform the same Locate, Calibrate, and Test routines. There is also a focal distance adjustment tool to the right of the video view. Video also features Capture and Decode functionality, which is similar to the Configuration interfaces (Communication, Read Cycle, Symbologies, I/O, Matchcode, and Diagnostics).

Initiates Calibration routine.

Activates the imager’s target pattern and initiates live video display of the symbol in the field of view.

Allows the user to take an image capture of the symbol in the field of view at any time, and to decode the symbol data. Similar to the Capture and Decode function in the Configuration views.

Initiates the Test routine. Allows the user to test the imager’s read rate and decodes per second, and also displays decoded symbol data in the field at the bottom of the screen, Click Stop to end the Test routine.

Clicking this icon enables the focal distance slide control to the right of the video view. The focal distance value is displayed just below the icon.

Symbol data and Test results are shown in this field.

10-4

When enabled, shows the symbol in higher contrast than the default contrast value.

MINI Hawk High Performance Imager User Manual

Page 249

Camera and IP Setup

Evaluation In Evaluation, you can view images currently in the imager, capture and decode a symbol, save it as a digital file, and perform histogram and line scan evaluations. When you click on the Evaluation tab, you will see the images that are currently stored in the imager. Click Receive to refresh this view. Click Capture/Decode to display the current stored image. Only one capture and decode event will occur, regardless of read cycle settings. Click Read to trigger a read cycle. If there is enough time in the read cycle, up to 32 good reads (or 6 full-scale images) can be captured and displayed, depending on the size of the images, and depending on the number enabled in Number of Captures under Capture Mode in the Camera Setup menu tree to the left of the tabs. If you click Save, the current image will be saved to the location of your choice. Note: An image can only be saved in the format in which it was uploaded to ESP. JPEG images will be saved as .jpg, and bitmaps will be saved as .bmp. When you click the JPEG Image box, notice that the Line Scan button is grayed out. The JPEG option allows faster captures and transfers, but since the JPEG standard compresses image data, it is not suitable for the more rigorous demands of line scan evaluation. JPEG also allows you to adjust the image quality (resolution) by adjusting the sliding tab between 1 and 100, 1 being the lowest quality and 100 being the highest. When possible, use the highest quality; when image transfer speed must be increased, use a lower image quality setting. Adjustments for this setting will depend on your specific hardware and software limitations.

MINI Hawk High Performance Imager User Manual

10-5

Page 250

Evaluation

Histogram Usage: Definition:

Useful in determining quality and contrast of symbols. A histogram is a graphic representation of the numeric count of the occurrence of each intensity (gray level) in an image. The horizontal axis represents the values of gray levels, and the vertical axis represents the number of pixels for each gray level.

Note: Since histograms are performed in the imager, the results will be saved regardless of whether the image was uploaded as a JPEG (.jpg) or a bitmap (.bmp). 1. From the Evaluation window, click the Histogram button. The current image is transferred into the histogram operation. This may take a moment, since all the relevant pixels are being evaluated intensively. 2. When the Histogram window opens, you may need to expand the window and/or adjust the scroll bars in order to bring the image into view. 3. To generate a histogram, click and drag your cursor diagonally across the symbol or a portion of the symbol. The image will be surrounded by an “area of interest box”, a dashed blue line with red anchor points that can be selected and moved by placing a cursor inside the box, and can be resized by clicking and dragging the anchor points.

10-6

MINI Hawk High Performance Imager User Manual