The text of a manual · part 23 of 38
MINI Hawk High Performance Imager User Manual, pages 221 to 230
Pages 221 to 230 of 380
The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan Mini Hawk
Page 221
Symbol Quality
Report Tab The Report tab allows the user to initiate Data Matrix Grading and to generate and save grading reports. To save the report as a PDF file, an HTML file, a CSV file, or an RTF file, click the Save Report button. Reports appear in the viewing area underneath the Data Matrix Grading and Save Report buttons.
The Symbol Quality interface is divided into three sections: Report, Locate, and Preferences.
The imager’s field of view is shown here. When grading is completed, the initial report is also shown in this viewing area.
MINI Hawk High Performance Imager User Manual
8-5
Page 222
Overview of Symbol Quality
Locate Tab The Locate tab allows the user to determine the position of the symbol within the imager’s field of view, and to optimize the imager’s camera settings for symbol quality evaluation.
Click the Locate button to display the symbol in the imager’s field of view.
8-6
Click the Calibrate button to optimize camera settings.
MINI Hawk High Performance Imager User Manual
Page 223
Symbol Quality
Preferences Tab The Preferences tab allows the user to set defaults that are automatically activated when grading is completed. For this reason, the user is advised to set preferences before performing grading.
This information is appended at the bottom of the report.
Choose the default report type to be generated when you click Save Report on the Report tab. Check Autofit Content to ensure that saved PDF report content will fit on a single page.
Typically you will be asked where you wish to store your report. If you do not want to be prompted to choose a file path, click Store Report without file path prompt.
Click the Include Image check box to output the captured symbol image with your saved report as a Bitmap or JPEG image file.
Enables ESP to parse UII symbol data into the correct fields and output order defined by the U.S. Department of Defense IUID initiative.
Returns all settings to default.
Returns all settings to most recent.
MINI Hawk High Performance Imager User Manual
8-7
Page 224
Symbol Quality Separator/Data Matrix Output Mode
Symbol Quality Separator/Data Matrix Output Mode Symbol Quality Separator applies to both Symbol Quality groups: ISO/IEC 16022 Symbol Quality Output and Omron Microscan Symbol Quality Output.
Symbol Quality Separator Definition: Serial Cmd: Default: Options:
Inserts a separator between each enabled field of the symbol quality output. <K708,symbol quality separator,output mode> <SP> (space character) Any ASCII character.
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K708h,3C> For >: <K708h,3E> For , : <K708h,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.
Symbol Quality Separator by ESP
When you double-click on the default separator SP, the Symbol Quality Separator Calculator appears. Use the calculator keypad for one-click separator configuration.
8-8
MINI Hawk High Performance Imager User Manual
Page 225
Symbol Quality
Data Matrix Output Mode Note: Output Mode applies to ISO/IEC 16022 symbol quality parameters. Definition: Serial Cmd: Default: Options:
Output Mode specifies how the four output parameters, if enabled, are formatted. <K708,symbol quality separator,output mode> Grade 0 = Grade 1 = Value
Grade If in Grade Mode, a grade (A,B,C,D) is appended to the symbol data.
Value If in Value Mode, the calculated value for the given parameter is appended to the symbol data.
MINI Hawk High Performance Imager User Manual
8-9
Page 226
ISO/IEC 16022 Symbol Quality Output
ISO/IEC 16022 Symbol Quality Output Symbol Quality Parameters for Data Matrix symbols specified by ISO/IEC 16022.
Symbol Contrast Usage: Definition:
Serial Cmd: Default: Options:
Lets the user know if contrast settings are less than acceptable. All the pixels that fall within the area of the test symbol, including its required zone, will be sorted by their reflectance values to select the darkest 10% and the lightest 10% of the pixels. The arithmetic mean of the darkest and the lightest pixels is calculated and the difference of the two means is the Symbol Contrast. (ANSI) Symbol Contrast grading is defined this way: A (4.0) if SC > 70% B (3.0) if SC > 55% C (2.0) if SC > 40% D (1.0) if SC > 20% F (0.0) if SC < 20% If enabled, the symbol contrast is appended to the symbol data according to the ISO/IEC 16022 Symbol Quality Output Mode setting. <K709,symbol contrast,print growth,axial non-uniformity,UEC> Disabled 0 = Disabled 1 = Enabled
Print Growth Definition:
Serial Cmd: Default: Options:
8-10
The extent to which dark or light markings appropriately fill or exceed their module boundaries. These values are determined by counting pixels in the clock pattern of the binary digitized image, then comparing it to a nominal value and minimum and maximum values. The print growth grade is defined in this way: A (4.0) if -.050 < PG < 0.50 B (3.0) if -.070 < PG < 0.70 C (2.0) if -.085 < PG < 0.85 D (1.0) if -.10 < PG < 1.00 F (0.0) if PG < -1.00 or PG > 1.00 If enabled, the print growth is appended to the symbol data according to the ISO/IEC 16022 Symbol Quality Output Mode setting. <K709,symbol contrast,print growth,axial non-uniformity,UEC> Disabled 0 = Disabled 1 = Enabled
MINI Hawk High Performance Imager User Manual
Page 227
Symbol Quality
Axial Non-Uniformity (Data Matrix Only) Definition:
Serial Cmd: Default: Options:
Axial non-uniformity is a measure of how much the sampling point spacing differs from one axis to another, namely AN = abs (XAVG YAVG) / ((XAVG + YAVG)/2) where abs () yields the absolute value. If a symbology has more than two major axes, then AN is computed for those two average spacings which differ the most. (ANSI) axial non-uniformity grading is defined this way: A (4.0) if AN < .06 B (2.0) if AN < .08 C (2.0) if AN < .10 D (1.0) if AN < .12 F (0.0) if AN > .12 If enabled, the axial non-uniformity is appended to the symbol data according the ISO/IEC 16022 Symbol Quality Output Mode setting. <K709,symbol contrast,print growth,axial non-uniformity,UEC> Disabled 0 = Disabled 1 = Enabled
Unused Error Correction (Data Matrix Only) Definition:
Serial Cmd: Default: Options:
The correction capacity of Reed-Solomon decoding is expressed in the equation: e + 2d < d - p, where e is the number of erasures, d is the number of error correction code words, and p is the number of code words reserved for error detection. A (4.0) if UEC > .62 B (3.0) if UEC > .50 C (2.0) if UEC > .37 D (1.0) if UEC > .25 F (0.0) if UEC < .25 If enabled, the UEC is appended to the symbol data according to the ISO/IEC 16022 Symbol Quality Output Mode setting. <K709,symbol contrast,print growth,axial non-uniformity,UEC> Disabled 0 = Disabled 1 = Enabled
MINI Hawk High Performance Imager User Manual
8-11
Page 228
ISO/IEC 16022 Symbol Quality Output by ESP
ISO/IEC 16022 Symbol Quality Output by ESP ESP’s Symbol Quality interface allows you to evaluate Data Matrix symbols for compliance with ISO/IEC 16022 requirements. First, determine which ISO/IEC 16022 Parameters you need to evaluate, using the Symbol Quality tree control.
Once you have set these Data Matrix evaluation parameters, go to the Preferences Tab and set your Data Matrix Grading Report output preferences.
After your output preferences are set, click the Data Matrix Grading button.
There will be a wait of a few seconds, and then the evaluation results will appear in the Symbol Quality view, in a format similar to the one shown below.
If you want to view the results in a report format, click the Save Report button. The report will be output in the format you chose in the Preferences dialog.
8-12
MINI Hawk High Performance Imager User Manual
Page 229
Symbol Quality
Omron Microscan Symbol Quality Output Percent Cell Damage (Data Matrix Only) Definition: Serial Cmd: Default: Options:
When this feature is enabled, the cell damage percentage is appended to data output. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
Total Read Time Definition: Serial Cmd: Default: Options:
The time that transpires between the image capture and the output of the decoded data, including locate time. When enabled, the total read time is appended to the symbol data. <K710,percent cell damage,total read timea,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled a. Total Read Time applies globally to all three Symbol Quality standards.
Capture Time Definition: Serial Cmd: Default: Options:
Capture time (in milliseconds) is a fixed “overhead” that includes the time of capture and transfer of the image. When enabled, the capture time is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
Locate Time Definition: Serial Cmd: Default: Options:
The time in milliseconds from the start of image processing until the symbol has been located and is ready to be decoded. When enabled, the locate time is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
MINI Hawk High Performance Imager User Manual
8-13
Page 230
Omron Microscan Symbol Quality Output
Decode Time Definition: Serial Cmd: Default: Options:
The time in milliseconds required to decode a symbol. When enabled, the decode time is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
Pixels Per Element (Data Matrix Only) Definition:
Serial Cmd: Default: Options:
The number of pixels for each element, either dark or light for both x and y directions. When enabled, the pixels per element value is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
Error Correction Level (Data Matrix Only) Definition: Serial Cmd: Default: Options:
Outputs the Data Matrix ECC level. When enabled, the ECC level is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
Matrix Size (Data Matrix Only) Definition: Serial Cmd: Default: Options:
8-14
Defines the symbol matrix size, in number of pixels in both the x and y axis. When enabled, the matrix size value is appended to the symbol data. <K710,percent cell damage,total read time,capture time,locate time,decode time,pixels per element,ECC level,matrix size,quiet zone,symbol angle> Disabled 0 = Disabled 1 = Enabled
MINI Hawk High Performance Imager User Manual