Page 261
Camera and IP Setup
AEC/AGC Mode Note: AEC/AGC Mode is only applicable to the High Speed version of the MINI Hawk. Definition:
Usage: Default: Options:
AEC/AGC Mode (Automatic Exposure Control/Automatic Gain Control Mode) maintains optimal self-adjusting exposure and gain settings. This ensures that acquired images fall in a desirable region of the camera’s sensitivity range for optimal image luminance. <K542,pixel sub-sampling,AEC/AGC mode,AEC/AGC brightness> Disabled 0 = Disabled 1 = AEC 2 = AGC 3 = AEC/AGC
AEC AEC enables Automatic Exposure Control. In this mode, the optimal setting for exposure (shutter) is computed and updated for every frame. It may take several frames to adjust the shutter value to the correct setting. The current camera shutter parameter is updated at the end of the read cycle (see Camera Settings). Note: The minimum (slowest) shutter setting will not exceed the frame read-out time of the current image dimension. For example, a full-size image has a minimum frame read-out time of 15 ms. Therefore, the slowest shutter that can be achieved is 15 ms, or 1/67.
AGC AGC enables Automatic Gain Control. In this mode, the optimal setting for gain is computed and updated for every frame. It may take several frames to adjust the gain value to the correct setting. The current camera gain parameter is updated at the end of the read cycle (see Camera Settings).
AEC/AGC AEC/AGC enables both Automatic Exposure Control and Automatic Gain Control. In this mode, the optimal settings for exposure (shutter) and gain are computed and updated for every frame. It may take several frames to adjust the shutter and gain values to the correct settings. Important: In this mode, only the Automatic Exposure Control (AEC) is active while the gain value remains fixed at its minimum setting. The Automatic Gain Control (AGC) only becomes active if the AEC has driven the shutter value to its minimum (slowest) setting and the desired image brightness has still not been obtained. When this occurs, the shutter value will remain fixed while gain is adjusted. The current camera shutter and camera gain parameters are then updated at the end of the read cycle (see Camera Settings).
AEC/AGC Brightness Note: AEC/AGC Brightness is only applicable to the High Speed version of the MINI Hawk. Definition: Usage: Default: Options:
AEC/AGC Brightness allows the desired image luminance to be adjusted within the range of 1 (darkest) to 56 (brightest). <K542,pixel sub-sampling,AEC/AGC mode,AEC/AGC brightness> 30 1 to 56
MINI Hawk High Performance Imager User Manual
10-17
Page 262
Camera Settings
Camera Settings Camera Settings are typically obtained during the calibration process, and do not necessarily need to be modified directly by the user.
Optics The MINI Hawk has three different optical configurations available: Standard Density, High Density, and Ultra High Density. Determine the optics of your imager and find the corresponding camera values in the following sections.
Standard Density, High Density, and Ultra High Density Optics Shutter Speed Usage:
Definition:
Serial Cmd: Default: Options:
Faster shutter speeds reduce blurring in faster applications. Slower shutter speeds are useful in slower applications and lower contrast applications. This value sets the exposure or integration time for the image sensor pixels. The shutter speed setting in relation to the speed of the object is critical. If a slow shutter speed is selected to capture fast-moving objects, blurring or smearing of the image will occur. As shutter speed is increased, more light and gain become necessary, because the pixels’ exposure time has decreased. <K541,shutter speed,gain> 250 (SD) 30 (HD) 300 (UHD) 15 to 12,500
Gain Usage: Definition:
Serial Cmd: Default: Options:
10-18
Can be used to adjust the brightness of the image. Sets the gain value for the image sensor. This setting can be configured through calibration, which is the recommended method. A higher gain value will increase the brightness of the image, but the visual noise reduction performance of the system is reduced. Before configuring gain settings, the desired shutter speed should already be set and the gain should be configured to optimize the shutter speed setting. <K541,shutter speed,gain> 20 0 to 33
MINI Hawk High Performance Imager User Manual
Page 263
Camera and IP Setup
Camera Settings (3 Megapixel) Camera parameters are typically obtained during the calibration process, and do not necessarily need to be modified directly by the user.
Optics The 3 Megapixel MINI Hawk Imager has two different optical configurations available: Standard Density and Micro Density. Determine the optics of your imager and find the corresponding camera values in the following sections.
Standard Density and Micro Density Optics Shutter Speed Usage: Definition:
Serial Cmd: Default: Options:
Faster shutter speeds reduce blurring in faster applications. Slower shutter speeds are useful in slower applications and lower contrast applications. Sets the exposure or integration time for the image sensor pixels. The shutter speed setting in relation to the speed of the object is critical. If a slow shutter speed is selected to capture fast-moving objects, blurring or smearing of the image will occur. As shutter speed is increased, more light and gain become necessary, because the pixels’ exposure time has decreased. <K541,shutter speed,gain> 60 (Standard Density) 80 (Micro Density) 15 to 15,000
Gain Usage: Definition:
Serial Cmd: Default: Options:
Can be used to adjust the brightness of the image. Sets the gain value for the image sensor. This setting can be configured through calibration, which is the recommended method. A higher gain value will increase the brightness of the image, but the image will be “noisier”. Important: Shutter Speed should be adjusted before Gain. Each of the image sensor’s colors has a separate gain setting, and the white balance adjustment provides gain offsets for color channels R (red), G (green), and B (blue) to provide consistent white across the image. Adjustments to both the R and B channels are usually required. The gain value that is set here is the base gain value for all colors. If a color requires additional gain to provide white balance, the offset is added to this gain value. However, when in the analog gain range, the gain + offset cannot exceed 42, and when in the digital gain range, the gain + offset cannot exceed 48. For optimal white balance, avoid setting gain near these values. Note: Omron Microscan recommends using only the analog gain range (0 to 42). Image quality is degraded within the digital gain range (43 to 48). <K541,shutter speed,gain> 20 Analog gain: 0 to 42 Digital gain: 43 to 48
MINI Hawk High Performance Imager User Manual
10-19
Page 264
Focal Distance
Focal Distance Definition:
Serial Cmd: Default:
Options:
This setting provides a means for configuring the focal distance of the imager. The input value is in terms of inches and is divided by 100 internally. For example, 400 sets the imager to a focal distance of 4 inches. It is important to note that the imager may not have an exact match for the focal position requested. The imager has a range of steps that are calibrated and mapped to focal positions. This input value is matched to the closest focal position step that the system supports. It is also important to keep in mind that the resolution of the system is not linear. As the imager’s focal distance setting increases, the resolution decreases. This effect is offset somewhat by the fact that the depth of field increases at greater focal distances. <K525,focal distance> Standard Density = 400 (4”) High Density = 400 (4”) Ultra High Density = 300 (3”) 200 (2”) to 600 (6”)
Note: In the factory, the imager calibrates its focus curve and matches the focus motor steps to various focal positions. Therefore, each imager has a slightly different focus map of stepper motor positions vs. focal positions. This allows the user to enter a focal distance that causes the imager to select the closest stepper motor position required to obtain the user-defined setting. In this way, there is consistency between imagers for any given focal distance input. Note: To view a list of focal distances supported by your imager, use the <K526> command.
10-20
MINI Hawk High Performance Imager User Manual
Page 265
Camera and IP Setup
Focal Distance (3 Megapixel) Definition:
Serial Cmd: Default: Options: Default: Options:
This setting provides a means for configuring the focal distance of the imager. The input value is in terms of inches and is divided by 100 internally. For example, 400 sets the imager to a focal distance of 4 inches. It is important to note that the imager may not have an exact match for the focal position requested. The imager has a range of steps that are calibrated and mapped to focal positions. This input value is matched to the closest focal position step that the system supports. It is also important to keep in mind that the resolution of the system is not linear. As the imager’s focal distance setting increases, the resolution decreases. This effect is offset somewhat by the fact that the depth of field increases at greater focal distances. <K525,focal distance> Standard Density = 400 (4”) 200 (2”) to 600 (6”) Micro Density = 300 (3”) 200 (2”) to 500 (5”)
Note: In the factory, the imager calibrates its focus curve and matches the focus motor steps to various focal positions. Therefore, each imager has a slightly different focus map of stepper motor positions vs. focal positions. This allows the user to enter a focal distance that causes the imager to select the closest stepper motor position required to obtain the user-defined setting. In this way, there is consistency between imagers for any given focal distance input. Note: To view a list of focal distances supported by your imager, use the <K526> command.
MINI Hawk High Performance Imager User Manual
10-21
Page 266
Focal Distance Table (Read-Only)
Focal Distance Table (Read-Only) Number of Focal Distances Definition: Serial Cmd: Options:
Specifies the number of focal distances supported by the imager. <K526,number of focal distances,focal distance> 1 to 255
Focal Distance Definition:
Serial Cmd: Options:
10-22
Each (x) output represents a focal distance that is supported by the imager. The values are specified in 1/100ths of an inch, but the focal distance increments and decrements are not that fine. The focal distance is defined from a curve equation whose constants are calibrated during factory setup. The output value is in terms of inches, and it is multiplied by 100 to remove the decimal place. For example, an output of 375 would signify a focal distance of 3.75”. <K526,number of focal distances,focal distance> 200 (2”) to 600 (6”)
MINI Hawk High Performance Imager User Manual
Page 267
Camera and IP Setup
Focal Distance Table (Read-Only) (3 Megapixel) Number of Focal Distances Definition: Serial Cmd: Options:
Specifies the number of focal distances supported by the imager. <K526,number of focal distances,focal distance> 1 to 255
Focal Distance Definition:
Serial Cmd: Options:
Each (x) output represents a focal distance that is supported by the imager. The values are specified in 1/100ths of an inch, but the focal distance increments and decrements are not that fine. The focal distance is defined from a curve equation whose constants are calibrated during factory setup. The output value is in terms of inches, and it is multiplied by 100 to remove the decimal place. For example, an output of 375 would signify a focal distance of 3.75”. <K526,number of focal distances,focal distance> 200 (2”) to 600 (6”) (Standard Density) 200 (2”) to 500 (5”) (Micro Density)
MINI Hawk High Performance Imager User Manual
10-23
Page 268
Increment Focus Position
Increment Focus Position Definition:
Serial Cmd: Options:
Increments the imager’s focus setting to the next focal distance supported by the imager. Note: Use the Focus Distance Table command <K526> to find the focal distance settings supported by your imager. <K525+> 200 (2”) to 600 (6”)
The following example assumes a focus position setting of 400 (4”), with access to the focus distance values shown in the imager response. Send: <K526?> Response: <K526,30,202,212,225,241,264,410,447,466,481,492,502,511,519,526,533, 539,545,550,556,561,565,570,574,578,582,586,590,594,597,601> The current focus position would be 410 (4.1”). Send: <K525+> Send: <K525?> Response: <K525,447>
Decrement Focus Position Definition:
Serial Cmd: Options:
Decrements the imager’s focus setting to the next focal distance supported by the imager. Note: Use the Focus Distance Table command <K526> to find the focal distance settings supported by your imager. <K525-> 200 (2”) to 600 (6”)
The following example assumes a focus position setting of 400 (4”), with access to the focus distance values shown in the imager response. Send: <K526?> Response: <K526,30,202,212,225,241,264,410,447,466,481,492,502,511,519,526,533, 539,545,550,556,561,565,570,574,578,582,586,590,594,597,601> The current focus position would be 410 (4.1”). Send: <K525-> Send: <K525?> Response: <K525,264>
10-24
MINI Hawk High Performance Imager User Manual
Page 269
Camera and IP Setup
Increment Focus Position (3 Megapixel) Definition:
Serial Cmd: Options:
Increments the imager’s focus setting to the next focal distance supported by the imager. Note: Use the Focus Distance Table command <K526> to find the focal distance settings supported by your imager. <K525+> 200 (2”) to 600 (6”) (Standard Density) 200 (2”) to 500 (5”) (Micro Density)
The following example assumes a focus position setting of 400 (4”), with access to the focus distance values shown in the imager response. Send: <K526?> Response: <K526,30,202,212,225,241,264,410,447,466,481,492,502,511,519,526,533, 539,545,550,556,561,565,570,574,578,582,586,590,594,597,601> The current focus position would be 410 (4.1”). Send: <K525+> Send: <K525?> Response: <K525,447>
Decrement Focus Position (3 Megapixel) Definition:
Serial Cmd: Options:
Decrements the imager’s focus setting to the next focal distance supported by the imager. Note: Use the Focus Distance Table command <K526> to find the focal distance settings supported by your imager. <K525-> 200 (2”) to 600 (6”) (Standard Density) 200 (2”) to 500 (5”) (Micro Density)
The following example assumes a focus position setting of 400 (4”), with access to the focus distance values shown in the imager response. Send: <K526?> Response: <K526,30,202,212,225,241,264,410,447,466,481,492,502,511,519,526,533, 539,545,550,556,561,565,570,574,578,582,586,590,594,597,601> The current focus position would be 410 (4.1”). Send: <K525-> Send: <K525?> Response: <K525,264>
MINI Hawk High Performance Imager User Manual
10-25
Page 270
Illumination Brightness
Illumination Brightness Definition:
Serial Cmd: Default: Options:
This feature allows the user to adjust the brightness of the illumination LEDs. Since the imager has control over the brightness of the illumination, it can provide consistent brightness output between imagers through a factory calibration operation. Each of the brightness settings is calibrated to provide the same level of intensity for each imager. <K536,brightness> High 0 = Off 1 = Low 2 = Medium 3 = High 4 = Constant
Constant When set to Constant, the illumination is the same as the Medium setting. However, the LEDs will always be on during a read cycle and will only be off between read cycles. This cuts down on perceptible LED flashing.
10-26
MINI Hawk High Performance Imager User Manual