Page 161
Symbologies
DataBar Limited (RSS Limited) Note: DataBar Limited was previously known as “RSS Limited”. Usage: Definition: Serial Cmd: Default: Options:
DataBar Limited is designed to be read by laser and CCD readers. It is not recommended for omnidirectional slot scanners. Encodes a smaller 14-digit symbol (74 modules wide) that is not omnidirectional. <K483,status> Disabled 0 = Disabled 1 = Enabled
DataBar-14 (RSS-14) Note: DataBar-14 was previously known as “RSS-14”. Usage: Definition:
Serial Cmd: Default: Options:
Used in the grocery, retail, and prescription drug industries where 14-digit EAN item identification may be needed. DataBar-14 is a fixed symbol length symbology that encodes 14 digits, including a 1-digit indicator. DataBar-14 is 96 modules wide. It can be stacked in two rows, it can read omnidirectionally if printed in full height, or horizontally if height-truncated for small marking. <K482,status> Disabled 0 = Disabled 1 = Enabled
MINI Hawk High Performance Imager User Manual
6-35
Page 162
PDF417
PDF417 Usage:
Definition:
Serial Cmd: Default: Options:
Used in applications where a large amount of information (over 32 characters) needs to be encoded within a symbol, typically where the symbol is transported from one facility to another. For example, an automobile assembly line might use a single symbol with multiple fields of information that will be read at several stations along the way, without reference to a database. A two-dimensional, multi-row (3 to 90), continuous, variable length symbology that has high data capacity for storing up to 2,700 numeric characters, 1,800 printable ASCII characters, or 1,100 binary characters per symbol. Each symbol character consists of 4 bars and 4 spaces in a 17-module structure. <K476,status,[unused],fixed symbol length status,fixed symbol length> Enabled 0 = Disabled 1 = Enabled
Note: Sending <a1> will cause PDF417 data to be prefaced with information consisting of error correction level (ECC Level n), number of rows (n Rows), number of columns (n Columns), number of informative code words (n Info Code Words) and the number of data characters (n Data Characters). This feature can be disabled by re-sending <a1>.
Fixed Symbol Length Status (PDF417) Serial Cmd: Default: Options:
<K476,status,[unused],fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (PDF417) Usage: Definition: Serial Cmd: Default: Options:
Used to increase data integrity by ensuring that only one symbol length will be accepted. When enabled, the PDF symbol must contain the same number of characters as the symbol length setting before it can be considered a good read. The imager will ignore any symbol not having the specified length. <K476,status,[unused],fixed symbol length status,fixed symbol length> 10 1 to 2710
Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to take effect.
6-36
MINI Hawk High Performance Imager User Manual
Page 163
Symbologies
MicroPDF417 Usage: Definition: Serial Cmd: Default: Options:
Used for labelling small items that need large data capacity. A variant of PDF417, a very efficient and compact stacked symbology that can encode up to 250 alphanumeric characters or 366 numeric characters per symbol. <K485,status,[unused],fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (MicroPDF417) Serial Cmd: Default: Options:
<K485,status,[unused],fixed symbol length status,fixed symbol length> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length (MicroPDF417) Usage: Definition:
Serial Cmd: Default: Options:
Used to increase data integrity by ensuring that only one symbol length will be accepted. When enabled, the MicroPDF417 symbol must contain the same number of characters as the symbol length setting before it can be considered a good read. The imager will ignore any symbol not having the specified length. <K485,status,[unused],fixed symbol length status,fixed symbol length> 10 1 to 366
Note: Fixed Symbol Length Status must be enabled for Fixed Symbol Length to take effect.
MINI Hawk High Performance Imager User Manual
6-37
Page 164
Composite
Composite When set to Enabled or Required, will decode the 2D composite component of a linear symbol. The linear symbol can be DataBar-14, DataBar Expanded, DataBar Limited, EAN-128, UPC-A, EAN-13, EAN-8, and UPC-E. Usage: Definition: Serial Cmd: Default: Options:
Allows reading by both linear and 2D readers. Combines 2D and linear width-modulated symbology on the same symbol where different messages can be read by each reader type. <K453,mode,separator status,separator> Disabled 0 = Disabled 1 = Enabled 2 = Required
Enabled If Composite is set to Enabled, the imager will decode both the 2D composite and linear components. However, if the 2D composite component is not decoded, the linear data will be sent by itself at the end of the read cycle.
Required If set to Required, the imager must decode both components, or a No Read will occur.
Separator Status (Composite) Usage: Definition: Serial Cmd: Default: Options:
Allows the user to distinguish between the main and Supplemental symbols. Separates the linear and the composite component. <K453,mode,separator status,separator> Disabled 0 = Disabled 1 = Enabled
Separator Character (Composite) Note: The Separator Character will be the same as the character defined in the Multisymbol Separator field of the <K222> command. Usage: Definition:
As required by the application. Allows the user to change the separator character from a comma to a new character. Serial Cmd: <K453,mode,separator status,separator> Default: , (comma) Options: Any ASCII character. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K453h,,,3C> For >: <K453h,,,3E> For , : <K453h,,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.
6-38
MINI Hawk High Performance Imager User Manual
Page 165
Symbologies
Narrow Margins/Symbology Identifier Narrow Margins Usage: Definition:
Serial Cmd: Default: Options:
Used when the leading and trailing edges of the symbols are smaller than the standard margin or other objects encroach into the margins. Allows the imager to read 1D symbols with quiet zones less than 8 times the width of the narrow bar element. “Quiet zone” is the space at the leading and trailing ends of a symbol. Each quiet zone can be as narrow as only five times the width of the narrow bar element when Narrow Margins is enabled. <K450,narrow margins,symbology identifier status> Enabled 0 = Disabled 1 = Enabled
Enabled When Narrow Margins is set to Enabled, the imager uses a 5x margin requirement for standard linear symbols.
MINI Hawk High Performance Imager User Manual
6-39
Page 166
Narrow Margins/Symbology Identifier
Symbology Identifier Definition:
Serial Cmd: Default: Options:
Symbology Identifier is an ISO/IEC 16022 standard prefix set of characters that identifies the symbol type. When enabled, the imager analyzes and identifies the symbology and adds a three-character identifying prefix to the data: • ] (closed bracket character) indicating the presence of a symbology identifier. • A, C, E, F, G, I, L, Q, Y, b, d, e, p, z • (A = Code 39; C = Code 128; E = UPC/EAN; F = Codabar; G = Code 93; I = I-2/5; L = PDF417 and MicroPDF417; Q = QR Code and Micro QR Code; Y = Postal Symbologies; b = BC412; d = Data Matrix; e = GS1 DataBar (RSS); p = Pharmacode; z = Aztec; Z = Non-Bar Code) • Modifier Example: ]d indicates a Data Matrix symbol. <K450,narrow margins,symbology identifier status> Disabled 0 = Disabled 1 = Enabled
Explanation of Modifiers for Code 39 and Interleaved 2 of 5 • For Code 39 and Interleaved 2 of 5, the modifier indicates Check Character and Check Character Output status. • For Code 39 only, Full ASCII must be enabled to see modifiers 4, 5, and 7. Modifier
Check Character
0 1 3 4 5 7
Disabled Enabled Enabled Disabled Enabled Enabled
Check Character Output N/A Enabled Disabled N/A Enabled Disabled
Full ASCII conversion performed (Code 39 only) No No No Yes Yes Yes
Example: ]A5 indicates a Code 39 symbol with Check Character and Check Character Output enabled and Full ASCII conversion performed.
Explanation of Modifiers for Other Symbologies • For Code 128, a 1 indicates EAN 128; otherwise the modifier is 0. • For QR Code and Micro QR Code, a 0 indicates QR Code; a 1 indicates Micro QR Code. • For Postal Symbologies, a 0 indicates POSTNET; a 1 indicates Japan Post; a 2 indicates Australia Post; a 3 indicates PLANET; a 4 indicates Royal Mail; a 5 indicates KIX; a 6 indicates UPU (56-bar); a 7 indicates UPU (75-bar); and an 8 indicates USPS4CB. Example: ]Y0 indicates a POSTNET symbol. • For all other symbologies, the modifier is 0.
6-40
MINI Hawk High Performance Imager User Manual
Page 167
Symbologies
Background Color Note: Background Color only applies to Pharmacode. Usage: Definition: Serial Cmd: Default: Options:
Symbol backgrounds are often White, or other very light colors. If the background is darker than the symbol, Black background should be enabled. Allows the user to specify the symbol background used in the application. <K451,background color> Both 0 = White 1 = Black 2 = Both
White When White background is enabled, the bars of the symbol are recognized as dark on a light background.
Black When Black background is enabled, the bars of the symbol are recognized as light on a dark background.
Both When Both is enabled, the imager will attempt to decode for white background first, and if there is no decode, will then attempt to decode for black background.
MINI Hawk High Performance Imager User Manual
6-41
Page 168
Background Color
6-42
MINI Hawk High Performance Imager User Manual
Page 169
7 I/O Parameters Contents I/O Parameters by ESP ................................................................................................................ 7-2 I/O Parameters Serial Commands ............................................................................................... 7-3 Symbol Data Output ..................................................................................................................... 7-4 No Read Message........................................................................................................................ 7-7 Read Duration Output .................................................................................................................. 7-8 Output Indicators .......................................................................................................................... 7-9 Beeper........................................................................................................................................ 7-13 LED Configuration ...................................................................................................................... 7-14 Serial Verification ....................................................................................................................... 7-15 EZ Button ................................................................................................................................... 7-17 EZ Button Modes........................................................................................................................ 7-19 Configurable Output 1 ................................................................................................................ 7-21 Trend Analysis Output 1............................................................................................................. 7-24 ISO/IEC 16022 Symbol Quality Output 1 ................................................................................... 7-27 Diagnostic Output 1.................................................................................................................... 7-30 Configurable Output 2 ................................................................................................................ 7-31 Trend Analysis Output 2............................................................................................................. 7-31 ISO/IEC 16022 Symbol Quality Output 2 ................................................................................... 7-31 Diagnostic Output 2.................................................................................................................... 7-31 Configurable Output 3 ................................................................................................................ 7-32 Trend Analysis Output 3............................................................................................................. 7-32 ISO/IEC 16022 Symbol Quality Output 3 ................................................................................... 7-32 Diagnostic Output 3.................................................................................................................... 7-32 Power-On/Reset Counts ............................................................................................................ 7-33 Time Since Reset ....................................................................................................................... 7-34 Service Message........................................................................................................................ 7-35 Frame Information ...................................................................................................................... 7-36 Image Output.............................................................................................................................. 7-37 Database Identifier Output ......................................................................................................... 7-40 Quality Output ............................................................................................................................ 7-41 Configuring EZ Trax Output ....................................................................................................... 7-42
This section includes instructions on setting up conditions for changing input/output electrical transitions for control of the imager’s internal and external devices. A discrete I/O (in/out) signal is an electrical transition from one voltage level to another so that digital switching can occur.
MINI Hawk High Performance Imager User Manual
7-1
Page 170
I/O Parameters by ESP
I/O Parameters by ESP
Click the Parameters button and then the I/O tab.
To change a setting, double-click the setting and use your cursor to scroll through the options.