The text of a manual · part 18 of 38
MINI Hawk High Performance Imager User Manual, pages 171 to 180
Pages 171 to 180 of 380
The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan Mini Hawk
Page 171
I/O Parameters
I/O Parameters Serial Commands Power On/Reset Counts
<K406,power-on,resets,power-on saves,power-on flash saves>
Time Since Reset
<K407,hours,minutes>
Service Message
<K409,status,service message,threshold,resolution>
Serial Verification
<K701,serial command echo status,serial command beep status,control/hex output>
Beeper
<K702,status>
Quality Output
<K704,quality output separator,decodes per trigger status>
Symbol Data Output
<K705,symbol data output status,when to output>
Read Duration Output
<K706,status,separator>
No Read Message
<K714,status,message>
Frame Information
<K734,output frame number,output coordinates>
LED Configuration
<K737,LED mode,ISO/IEC 16022 grade>
Image Output
<K739,image output mode,communication port,file format,JPEG quality>
Target/Flood LEDs
<K750,green flash LED status,target pattern LED status,green flash duration>
EZ Trax Output
<K757,comm port,image mode,image format,JPEG quality,object info output,grade output>
Database Identifier Output
<K759,status,separator>
EZ Button
<K770,global status,default on power-on,load Configuration Database, save for power-on>
EZ Button Modes
<K771,single beep,two beeps,three beeps,four beeps>
Trend Analysis Output 1
<K780,trend analysis mode,trigger evaluation period,number to output on,decodes per trigger threshold>
Trend Analysis Output 2
<K781,trend analysis mode,trigger evaluation period,number to output on,decodes per trigger threshold>
Trend Analysis Output 3
<K782,trend analysis mode,trigger evaluation period,number to output on,decodes per trigger threshold>
Diagnostic Output 1
<K790,unused 1,service unit>
Diagnostic Output 2
<K791,unused 1,service unit>
Diagnostic Output 3
<K792,unused 1,service unit>
ISO/IEC 16022 Symbol Quality Output 1
<K800,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold>
ISO/IEC 16022 Symbol Quality Output 2
<K801,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold>
ISO/IEC 16022 Symbol Quality Output 3
<K802,output on symbol contrast,symbol contrast threshold,output on print growth,print growth threshold,output on axial non-uniformity,axial non-uniformity threshold,output on UEC,UEC threshold>
Configurable Output 1
<K810,output on,output state,pulse width,output mode>
Configurable Output 2
<K811,output on,output state,pulse width,output mode>
Configurable Output 3
<K812,output on,output state,pulse width,output mode>
MINI Hawk High Performance Imager User Manual
7-3
Page 172
Symbol Data Output
Symbol Data Output Symbol Data Output Status Note: Symbol Data Output relates to data and should not be confused with Outputs 1, 2, and 3 listed in the Output Parameters which describe output states and functions. Usage: Definition: Serial Cmd: Default: Options:
Useful when the host needs symbol data only under certain conditions. Defines the conditions under which decoded symbol data is transmitted to the host. <K705,symbol data output status,when to output> Good Read 0 = Disabled 1 = Match 2 = Mismatch 3 = Good Read Note: Symbol Data Output Status, if set to Match or Mismatch, will not take effect unless Matchcode Type is enabled and a master symbol is loaded into memory.
Disabled Usage:
Definition:
It is useful when an application only needs to use the discrete outputs and can allow the imager to do the decision-making. When Disabled, the host does not need the symbol data and the communication lines are used only for setup and status checks. When set to Disabled, the imager will not transmit any data that is generated during a read cycle (symbols, No Reads, etc.)
Match Usage: Definition:
Match is used in an application that requires specific symbol information and needs to sort, route, or verify based on matching the specific symbol data. When set to Match, the imager transmits symbol data whenever a symbol matches a master symbol. However, if Matchcode Type is Disabled, it transmits on any good read. Note: A No Read can still be transmitted if Enabled.
Mismatch Usage: Definition:
Mismatch is typically used as a flag within the host system to prevent an item from being routed in the wrong container. With Mismatch enabled, the imager transmits symbol data whenever the symbol data information does NOT match the master symbol. Note: A No Read can still be transmitted if Enabled.
7-4
MINI Hawk High Performance Imager User Manual
Page 173
I/O Parameters
Good Read Usage: Definition:
Good Read is used when an application requires all symbol data to be transmitted. It’s typically used in tracking applications in which each object is uniquely identified. With Good Read enabled, the imager transmits symbol data on any good read regardless of Matchcode Type setting. Note: A No Read can still be transmitted if Enabled.
MINI Hawk High Performance Imager User Manual
7-5
Page 174
Symbol Data Output
When to Output Symbol Data Definition: Serial Cmd: Default: Options:
This command allows the user to choose when symbol data can be sent to the host. <K705,symbol data output status,when to output> As Soon As Possible 0 = ASAP 1 = End of Read Cycle
As Soon As Possible Usage: Definition:
As Soon As Possible is useful in applications in which symbol data needs to be moved quickly to the host, typically when the host is making decisions based on symbol data. Enabling As Soon As Possible causes symbol data to be sent to the host immediately after a symbol has been successfully decoded.
Note: More than one decode might in fact be required to qualify as a good read, depending on how Decodes Before Output is set.
End of Read Cycle Usage: Definition:
End of Read Cycle is useful in timing-based systems in which the host is not ready to accept data at the time that it is decoded. Enabling End of Read Cycle means that symbol data does not get sent to the host until the read cycle ends with a timeout or new trigger.
End of read cycle
Start of read cycle Read cycle duration Host activates trigger
7-6
This is when host expects output
MINI Hawk High Performance Imager User Manual
Page 175
I/O Parameters
No Read Message Usage: Definition:
Used in applications where the host needs serial verification that a symbol has not been read and especially useful in new print verification. When enabled, and if no symbol has been decoded before timeout or the end of the read cycle, the No Read message will be transmitted to the host.
No Read Message Mode Serial Cmd: Default: Options:
<K714,No Read message status,No Read message> Enabled 0 = Disabled 1 = Enabled
Disabled Only symbol data is output after a read cycle.
Enabled When the imager is in a triggered mode, a No Read message will be appended for each failed read attempt.
No Read Message Definition: Serial Cmd: Default: Options:
Any combination of ASCII characters can be defined as the No Read message. <K714,No Read message status,No Read message> NOREAD A string of up to 64 characters.
Note: No Read Message will only be transmitted if Symbol Data Output is set to Match, Mismatch, or Good Read. No Read Message can be set to any ASCII character. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K714h,,3C> For >: <K714h,,3E> For , : <K714h,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.
MINI Hawk High Performance Imager User Manual
7-7
Page 176
Read Duration Output
Read Duration Output Usage: Definition:
Useful in evaluating actual read cycle timing results, especially when initially setting up an application to determine maximum line speed (obtainable based on spacing between symbols.) When enabled the duration of the read cycle (in milliseconds) is appended to the symbol data. The read duration is the time from the beginning of the read cycle until data is output.
Read Duration Output Mode Serial Cmd: Default: Options:
<K706,status,separator> Disabled 0 = Disabled 1 = Enabled
Important: To measure the entire read cycle when in External Level trigger mode, set When to Output Symbol Data to End of Read Cycle. This output can measure over 49 days’ worth of duration; if exceeded, the “OVERFLOW” message will be output in place of the duration.
Read Duration Output Separator Definition: Serial Cmd: Default: Options:
User defined character that separates the symbol information from the Read Duration Output. <K706,status,separator> [space character] Any ASCII character.
Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K706h,,3C> For >: <K706h,,3E> For , : <K706h,,2C> See ASCII Character Entry Modifier on page 3-32 for a detailed explanation of how to enter ASCII characters as hex values.
7-8
MINI Hawk High Performance Imager User Manual
Page 177
I/O Parameters
Output Indicators The MINI Hawk has a beeper and three LED arrays, as follows: 1. A target pattern of blue LEDs for centering the field of view, which is projected from the front of the imager . 2. An array of green LEDs projected from the front of the imager that can be programmed to flash in response to user-defined conditions. 3. A row of five status LEDs on the side of the imager.
Green Flash Mode Usage: Definition: Serial Cmd: Default: Options:
Used as a visual verification that a good read has occurred. An array of green LEDs in the front of the imager can be programmed to flash in response to user-defined conditions. <K750,green flash mode,target pattern status,green flash duration> Good Read 0 = Disabled 1 = Good Read 2 = Static Presentation 3 = Match 4 = Mismatch 5 = Strobe
Disabled Green flash LEDs are disabled.
Good Read Green flash LEDs will flash when a good read condition is met or when Matchcode is enabled and a match occurs.
MINI Hawk High Performance Imager User Manual
7-9
Page 178
Output Indicators
Static Presentation Mode Static Presentation Mode is used in conjunction with Continuous Read Mode: <K200,0>. When operating in Static Presentation Mode, the red LEDs will illuminate while the imager is searching for a symbol in Continuous Read Mode. When a symbol is placed in the field of view and a good read occurs, the green LEDs will illuminate and stay on for the duration of time set in Green Flash Duration. Only one read will occur during that time unless more than one symbol is enabled in Number of Symbols. Note: If Static Presentation Mode is selected but the imager is not in Continuous Read, the Green Flash will not occur. To use Static Presentation: 1. Enable Continuous Read. 2. Select the number of symbols. 3. Enable Static Presentation in Green Flash Mode. 4. Select the read time in Green Flash Duration.
Match The green LEDs will flash when a match condition is met. If multisymbol is enabled, then green flash LEDs will illuminate only if all symbols qualify as a match. If matchcode is disabled, then this mode will activate the LEDs on a good read.
Mismatch Same as Match, except that LEDs will illuminate on a mismatch.
Strobe Green flash LEDs will act as an illumination strobe for image capture. If it is required that the green flash LEDs be the only illumination for image capture, then the internal illumination LEDs can be disabled.
7-10
MINI Hawk High Performance Imager User Manual
Page 179
I/O Parameters
Target Pattern Usage: Definition: Serial Cmd: Default: Options:
Assists users in positioning and locating symbols in the center of the imager’s field of view. The user can control when the targeting system is ON or OFF, and can save this condition for power-on. <K750,green flash mode,target pattern status,green flash duration> Always ON 0 = Always OFF 1 = ON only when not in the read cycle 2 = ON only when in the read cycle 3 = Always ON
Always OFF The target pattern will remain OFF at all times unless overridden by the EZ button or operational command.
ON Only When Not in the Read Cycle The target pattern is always ON except during the read cycle. If the EZ button or operational command overrides this setting, the target pattern will remain on at all times.
ON Only When in the Read Cycle The target pattern will remain OFF except during the read cycle. If the EZ button or operational command overrides this setting, the target pattern will remain on at all times.
Always ON The target pattern is always ON.
MINI Hawk High Performance Imager User Manual
7-11
Page 180
Output Indicators
Green Flash Duration Usage: Definition: Serial Cmd: Default: Options:
7-12
Provides visual verification that a good read has occurred. When a good read occurs, the green LEDs will illuminate and stay on for the time set in the Green Flash Duration value. <K750,green flash mode,target pattern status,green flash duration> 100 (1 second) 0 to 65535 (in 10 ms increments)
MINI Hawk High Performance Imager User Manual