Page 181

I/O Parameters

Beeper Usage: Definition: Serial Cmd: Default: Options:

An audible verification that either a good read or a No Read has occurred. A beep is emitted after each good read or No Read. <K702,beeper status> Good Read 0 = Disabled 1 = Good Read 2 = No Read

Note: The beeper will also sound at any of the following times: • When the imager is defaulted. • When a send/save command is sent from ESP. • At the conclusion of a calibration procedure. • When a <Z>, <Zp>, <Zrd>, or <K701,,1> command is sent.

MINI Hawk High Performance Imager User Manual

7-13

Page 182

LED Configuration

LED Configuration Usage: Definition: Serial Cmd: Default: Options:

Useful as a visible indicator of read rates and symbol quality. Determines the mode in which the status LEDs operate. <K737,LED mode,ISO/IEC 16022 grade> Standard 0 = Standard 1 = ISO/IEC 16022 grade

In ISO/IEC 16022 grade mode the LEDs represent the grade of the first Data Matrix symbol decoded in the read cycle. The parameter to be graded is set in the ISO/IEC 16022 Grade options. For example, to program the LEDs to indicate the ISO/IEC 16022 print growth grade, set LED Mode to ISO/IEC 16022 Grade and set ISO/IEC 16022 Grade to Print Growth. If all the LEDs from 20% to 100% are illuminated, the read result is a grade A; if only the 20% LED is illuminated, the result is a grade F.

Standard In Standard Mode, the STATUS LED indicates read cycle status and the GOOD READ LED illuminates upon a good read at the end of a read cycle. In a read rate test, these LEDs represent the percentage of good reads per images captured.

ISO/IEC 16022 Grade Usage: Definition: Serial Cmd: Default: Options:

7-14

Provides visual grading of specific ISO/IEC 16022 parameters. Determines which ISO/IEC 16022 parameter the imager will grade via the LEDs. <K737,LED mode,ISO/IEC 16022 grade> Final Grade 0 = Final Grade 1 = Symbol Contrast 2 = Print Growth 3 = Axial Non-Uniformity 4 = Unused ECC

MINI Hawk High Performance Imager User Manual

Page 183

I/O Parameters

Serial Verification Allows the user to verify configuration command status.

Serial Command Echo Status Usage:

Definition:

Function:

Serial Cmd: Default: Options:

This command is useful in removing any doubt about the imager’s interpretation of any configuration command. For example, if the current preamble is “SOM” and <K701,1,START> is entered, the imager will echo back <K701,SOM> since the attempted entry “START” exceeds the four character limit for that command. Therefore, it is rejected and the existing “SOM” message is echoed back and remains the preamble message. When enabled, a configuration command received from the host is echoed back to the Host Imager host with the resultant settings. If a command with multiple fields is processed, some of the fields may have been processed properly while others were not. The changes will appear in the string echoed back so that the user will know which fields did or did not change. <K701,serial command echo status,serial command beep status, control/hex output> Disabled 0 = Disabled 1 = Enabled

Serial Command Beep Status Usage: Definition: Function:

Serial Cmd: Default: Options:

Used to audibly verify the acceptance and validity of a command. Causes the imager to beep once whenever a K command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the imager beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response. <K701,serial command echo status,serial command beep status, control/hex output> Disabled 0 = Disabled 1 = Enabled

MINI Hawk High Performance Imager User Manual

7-15

Page 184

Serial Verification

Control/Hex Output Usage: Definition:

Serial Cmd: Default: Options:

7-16

Useful for viewing settings with binary characters when using serial commands on a terminal. Determines the response to a Serial Command Echo or status request command. When set to Control, two characters are transmitted to represent a non-displayable character. For example, a carriage return will be shown as: ^M. <K701,serial command echo status,serial command beep status,control/hex output> Control 0 = Control 1 = Hex

MINI Hawk High Performance Imager User Manual

Page 185

I/O Parameters

EZ Button The EZ button has four positions, selectable by the length of time the button is held down, and indicated by one, two, three, and four beeps in succession. Each position can be programmed for any of eight options. Definition: Serial Cmd: Default: Options:

Serves as a master switch to enable/disable the EZ button status. <K770,global status,default on power-on,load Configuration Database, save for power-on> Enabled 0 = Disabled 1 = Enabled 2 = Trigger 3 = Unlatch Outputs 4 = Parameter Switch

Global Status Disabled When set to Disabled, the EZ button does not function.

Enabled When selected, the EZ button is enabled and the function of each button position is selected by the EZ Button Mode command.

Trigger When selected, the EZ button acts as a trigger for the imager to start and end read cycles. All other button operations are inactive. In External Level: In External Edge:

The read cycle endures for as long as the EZ button is pressed, unless a timeout occurs and Timeout is enabled for End of Read Cycle. As with Level, Edge allows a read cycle to be initiated by pressing the EZ button, but unlike Level, the read cycle ends with a good read output, a timeout, or a new trigger.

Unlatch Outputs In this configuration, the EZ button will unlatch any logic outputs that have been latched.

Parameter Switch The parameter switch toggles between custom defaults and power-on settings. The condition is the same as that achieved by sending the <Arc> and <Arp> commands consecutively.

MINI Hawk High Performance Imager User Manual

7-17

Page 186

EZ Button

Default on Power-On Definition: Serial Cmd: Default: Options:

When enabled, if the EZ button is held down on power-on the imager will default to customer defaults and save for power-on. This is the same as sending a <Zrc> command. <K770,global status,default on power-on,load Configuration Database, save for power-on> Enabled 0 = Disabled 1 = Enabled

Load Configuration Database Definition:

Serial Cmd: Default: Options:

Allows the user to load the Configuration Database with calibration results. When the user performs a calibration using the EZ button, all the database entries are moved down one index and the results of the calibration are saved to index 1. The results will be saved as current settings as well. <K770,global status,default on power-on,load Configuration Database, save for power-on> Enabled 0 = Disabled 1 = Enabled

Save for Power-On Definition: Serial Cmd: Default: Options:

7-18

If enabled, after calibration is complete, all parameters will be saved for power-on. <K770,global status,default on power-on,load Configuration Database, save for power-on> Disabled 0 = Disabled 1 = Enabled

MINI Hawk High Performance Imager User Manual

Page 187

I/O Parameters

EZ Button Modes Usage: Definition: Serial Cmd: Options:

Useful for performing multiple, repetitive tasks at the work site. Allows the user to program each of the EZ button’s 4 positions from a selection of 8 modes. <K771,position 1 mode,position 2 mode,position 3 mode,position 4 mode> 0 = Disabled 1 = Enabled

Single Beep 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Unused 9 = Bar Code Config.

Two Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Unused 9 = Bar Code Config.

Three Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Unused 9 = Bar Code Config.

Four Beeps 0 = Disabled 1 = Read Rate 2 = Calibrate 3 = Save for Power-On 4 = Unused 5 = Load New Master 6 = Unused 7 = Target System 8 = Unused 9 = Bar Code Config.

Disabled When set to disabled, the associated button position will have no function associated with it, and the position will be skipped over.

Read Rate Read Rate will be initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from the terminal. To exit Read Rate Mode quickly press and release the EZ button.

Calibrate Calibration will be initiated when the associated button position is selected. To abort calibration, quickly press and release the EZ button.

Save for Power-On All imager settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from the terminal.

Load New Master Functions in the same way as new master pin input whenever the associated button position is selected. The new master pin’s Consecutive Decode requirement holds true for this function.

MINI Hawk High Performance Imager User Manual

7-19

Page 188

EZ Button Modes

Target System Turns on the target pattern whenever the associated button position is selected. To disable, quickly press and release the EZ button. Note: This mode is the only one that does not require that the button be released before taking effect. Thus, as soon as the imager beeps the appropriate number of times for the position, it will take effect. If it is necessary to have the target system on before another operation such as calibration or read rate is performed, ensure that the target system mode is assigned a lower position so that it will be activated first.

Bar Code Configuration Enables bar code configuration mode whenever the associated button position is selected. When enabled, the imager can accept configuration commands from symbols. To disable, quickly press and release the EZ button.

EZ Button Operation To execute EZ button commands:

Single Beep (Position #1) Hold down button until a single beep is heard (and the 20% LED illuminates).

Two Beeps (Position #2) Hold down button until two quick beeps are heard (and the 20% and 40% LEDs illuminate.)

Three Beeps (Position #3) Hold down button until three quick beeps are heard (and the 20%, 40%, and 60% LEDs illuminate).

Four Beeps (Position #4) Hold down button until four quick beeps are heard (and the 20%, 40%, 60%, and 80% LEDs illuminate).

7-20

MINI Hawk High Performance Imager User Manual

Page 189

I/O Parameters

Configurable Output 1

Usage: Definition: Serial Cmd: Default: Options:

This option provides discrete signalling to host software to control external devices such as PLCs and relays. It is useful for routing, sorting, and to prevent mis-packaging and mis-routing. Sets the discrete output functions for specific user-selected conditions. Allows the user to set the conditions under which an output (or outputs) will be activated. <K810,output on,output state,pulse width,output mode> Mismatch or No Read 0 = Mismatch or No Read 1 = Match (or Good Read) 2 = Mismatch 3 = No Read 4 = Trend Analysis 5 = Symbol Quality 6 = Diagnostic Warning 7 = In Read Cycle

Note: If Output On is set to any mode containing Match or Mismatch, the transition (switching) will only occur if Matchcode Type is enabled and Master Symbol(s) are loaded into memory.

Mismatch or No Read Activates discrete output when the data does not match that of the master symbol or the symbol has not been decoded before the end of the read cycle.

Match (or Good Read) Activates a discrete output when the symbol data matches the master symbol.

Mismatch Activates a discrete output whenever the symbol data does not match that of the master symbol.

No Read Activates a discrete output whenever the symbol data is not decoded before the end of the read cycle.

MINI Hawk High Performance Imager User Manual

7-21

Page 190

Configurable Output 1

Trend Analysis Usage: Definition:

Typically used when successful decodes are occurring but a discrete output is needed to flag a trend in quality issues. Activates discrete output when a trend analysis condition is met, depending on the trend analysis option enabled.

Symbol Quality Usage: Definition:

Typically used when a discrete indication is needed to flag a symbol quality condition. Activates discrete output when a symbol quality condition is met, depending on the symbol quality option enabled.

Diagnostic Warning Usage: Definition:

Typically used when a discrete indication of a diagnostic condition is needed. Activates discrete output when a diagnostic warning condition is met, depending on the diagnostic option enabled.

In Read Cycle Definition:

7-22

Activates a discrete output when the imager is in a read cycle.

MINI Hawk High Performance Imager User Manual