The text of a manual · part 13 of 38
MINI Hawk High Performance Imager User Manual, pages 121 to 130
Pages 121 to 130 of 380
The original document is the PDF (5.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan Mini Hawk
Page 121
Read Cycle
Image Processing Timeout Usage: Definition:
Serial Cmd: Default: Options:
Useful in higher speed applications where image processing time is long enough that not all captures have an opportunity to be processed. Specifies the maximum amount of time to process a captured image. When the timeout expires, the image processing is aborted. This timeout works in both Rapid Capture and Continuous Capture modes, as well as with the Configuration Database. <K245,image processing timeout> 5000 ms (5 sec.) 1 to 65535 (in 1 ms increments)
Notes: • The timeout period does not include capture time. • If a timeout occurs during processing and no symbols in the field of view have been decoded, the image will be recorded as a No Read. For this reason, a longer timeout should be tried to ensure that the symbol is decoded successfully.
MINI Hawk High Performance Imager User Manual
5-23
Page 122
Image Storage
Image Storage Image Storage Type Definition:
Serial Cmd: Default: Options:
Allows the user to store images from separate read cycles and to retrieve them later. The number of available slots for storage depends on the mode of operation. If the imager is in Rapid Capture Mode, the number of images that can be stored is equivalent to the maximum number of the rapid count (the current rapid count setting). If the imager is in Continuous Capture Mode, a number of images equivalent to the maximum number of the rapid count minus 3. <K244,image storage type,image storage mode> Disabled/Clear 0 = Disabled/Clear 1 = Store on No Read
Disabled/Clear Upon selection of this option, all saved images will be cleared and the imager will not store images for later viewing.
Store on No Read This option will cause the imager to store an image upon exiting the read cycle for retrieval at a later time. If multiple captures are present during the duration of a read cycle, the stored image will be the last image processed for that read cycle. This image is stored in RAM and can be retrieved as long as power is not cycled to the imager, and as long as the imager has not been reset via a reset/save sequence. Other commands that can initialize storage in RAM are ones that change capture modes or put the imager in a test capture mode.
Image Storage Mode Serial Cmd: Default: Options:
<K244,image storage type,image storage mode> First Mode 0 = First Mode 1 = Last Mode
First Mode This mode allows the imager to store images until the available image memory has been filled. At that point the imager will stop saving additional images. In this mode, you will always have the first image captured, because the saving process stops once memory has been filled.
Last Mode In this mode, image storage continues after available memory limits are reached. The oldest image in memory is overwritten, so you will always have the most recent stored image.
5-24
MINI Hawk High Performance Imager User Manual
Page 123
Read Cycle
Image Storage Example The following example assumes that the imager is in a rapid capture mode of 3 captures. Number of Symbols: Frame # 1: Frame # 2: Frame # 3: Read Cycle Result: Stored Frame:
1 No Read No Read Good Read, Symbol # 1 Good Read None
Number of Symbols: Frame # 1: Frame # 2: Frame # 3: Read Cycle Result: Stored Frame:
1 No Read No Read No Read No Read Frame # 3
Number of Symbols: Frame # 1: Frame # 2: Frame # 3: Read Cycle Result: Stored Frame:
2 No Read No Read Good Read, Symbol # 1 No Read Frame # 2
MINI Hawk High Performance Imager User Manual
5-25
Page 124
Decodes Before Output
Decodes Before Output Definition: Serial Cmd: Default: Options:
5-26
This value specifies the number of times a symbol needs to be read to qualify as a good read. <K221,decodes before output> 1 1 to 255
MINI Hawk High Performance Imager User Manual
Page 125
Read Cycle
Setting Up the Imager for EZ Trax If you are using EZ Trax software, it is important to set up the MINI Hawk correctly before beginning. Click the Read Cycle tab to display the Read Cycle tree control.
Set Trigger Mode, <K200>, to External Edge.
Set Capture Mode, <K241>, to Rapid Capture.
Once these Read Cycle parameters are set, you will be ready to connect to EZ Trax. For a description of how to configure EZ Trax using serial commands or ESP, see Configuring EZ Trax Output in Chapter 7, I/O Parameters. For more detailed information about using EZ Trax, refer to the Help menu in EZ Trax software, or the EZ Trax Quick Start Guide, available on the Tools Drive. MINI Hawk High Performance Imager User Manual
5-27
Page 126
Setting Up the Imager for EZ Trax
5-28
MINI Hawk High Performance Imager User Manual
Page 127
6 Symbologies Contents Symbologies by ESP.................................................................................................................... 6-2 Symbologies Serial Commands ................................................................................................... 6-3 Data Matrix ................................................................................................................................... 6-4 Aztec Code................................................................................................................................... 6-6 QR Code ...................................................................................................................................... 6-7 Micro QR Code............................................................................................................................. 6-8 Code 39........................................................................................................................................ 6-9 Code 128/EAN 128 .................................................................................................................... 6-12 BC412 ........................................................................................................................................ 6-15 Interleaved 2 of 5........................................................................................................................ 6-16 Code 93...................................................................................................................................... 6-19 Codabar...................................................................................................................................... 6-20 UPC/EAN ................................................................................................................................... 6-23 Pharmacode ............................................................................................................................... 6-27 Postal Symbologies.................................................................................................................... 6-29 GS1 DataBar (RSS) ................................................................................................................... 6-34 PDF417 ...................................................................................................................................... 6-36 MicroPDF417 ............................................................................................................................. 6-37 Composite .................................................................................................................................. 6-38 Narrow Margins/Symbology Identifier ........................................................................................ 6-39 Background Color....................................................................................................................... 6-41
This section describes the various symbol types that can be read and decoded by the MINI Hawk. See the following sites for additional information about linear and 2D symbologies: http://www.aimglobal.org/standards/aimpubs.asp http://barcodes.gs1us.org/dnn_bcec/Default.aspx?tabid=82
MINI Hawk High Performance Imager User Manual
6-1
Page 128
Symbologies by ESP
Symbologies by ESP
Click the Parameters button and then the Symbologies tab.
To change a setting, double-click the setting and use your cursor to scroll through the options.
To open nested options, single-click the +.
6-2
MINI Hawk High Performance Imager User Manual
Page 129
Symbologies
Symbologies Serial Commands Narrow Margins/Symbology ID Background Color Composite Aztec Code Micro QR Code Postal Symbologies Code 39 Codabar Interleaved 2 of 5 UPC/EAN Code 128/EAN 128
Code 93 PDF417 Pharmacode Data Matrix QR Code BC412 DataBar-14 (RSS-14) DataBar Limited (RSS Limited) DataBar Expanded (RSS Expanded) MicroPDF417
<K450,narrow margin status,symbology identifier status> <K451,background color> <K453,symbology status,separator status,separator> <K458,status> <K459,status> <K460,postal symbology type,POSTNET status,PLANET status, USPS4CB status,POSTNET allow B and B’ fields,Australia Post allow 0 FCC> <K470,status,check character status,check character output status, large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> <K472,status,check character status,check character output status, symbol length #1, symbol length #2, guard bar status,range mode status> <K473,UPC status,EAN status,supplemental status,separator status, separator character,supplemental type,format UPC-E as UPC-A> <K474,status,fixed symbol length status,fixed symbol length,EAN 128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> <K475,status,fixed symbol length status,symbol length> <K476,status,[unused],fixed symbol length status,fixed symbol length,[unused],codeword collection> <K477,status,fixed bar count status,fixed bar count,minimum bar count,bar width mode,direction,fixed threshold value> <K479,ECC 200 status, ECC 000 status,ECC 050 status, ECC 080 status,ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> <K480,status> <K481,status,check character output,fixed symbol length status, fixed symbol length> <K482,status> <K483,status> <K484,status,fixed symbol length status,fixed symbol length> <K485,status,[unused],fixed symbol length status,fixed symbol length>
MINI Hawk High Performance Imager User Manual
6-3
Page 130
Data Matrix
Data Matrix Usage: Definition:
Very useful where information needs to be packed into a small area, and/or where symbols need to be applied directly to the substrate with laser etching, chemical etching, dot peen, or other methods. Data Matrix is a type of Matrix symbology and has subsets ECC 000 - ECC 200. ECC 200 symbols have an even number of rows and an even number of columns. Most of the symbols are square with sizes from 10x10 to 144x144. Some symbols, however, are rectangular, with sizes from 8x18 to 16x48. All ECC 200 symbols can be recognized by the upper right corner module being light (binary 0) instead of dark.
ECC 200 Definition: Serial Cmd: Default: Options:
When enabled, will decode ECC 200 Data Matrix symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status, ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Enabled Note: This is the only symbol type enabled by default. 0 = Disabled 1 = Enabled
ECC 000 Definition: Serial Cmd: Default: Options:
When enabled, will decode ECC 000 symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status, ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Disabled 0 = Disabled 1 = Enabled
ECC 050 Definition: Serial Cmd: Default: Options:
6-4
When enabled, will decode ECC 050 symbols. <K479,ECC 200 status,ECC 000 status,ECC 050 status,ECC 080 status, ECC 100 status,ECC 140 status,ECC 120 status,ECC 130 status> Disabled 0 = Disabled 1 = Enabled
MINI Hawk High Performance Imager User Manual