Operating Instructions: CLV 41x Bar Code Scanner, Standard line

Manual142 pagesPDF 2.2 MB

Operating instructions for the SICK CLV 410, CLV 412 and CLV 414 fixed-focus laser bar code scanners: install, connect, set up, fix.

Download the PDF2.2 MB

Covers · 3 models

The models it covers

Summary

What is in it

The SICK operating instructions for the CLV 41x line of fixed-focus laser bar code scanners: the CLV 410 (Standard), CLV 412 (High Density) and CLV 414 (Short Range), in line and raster scanner variants. It covers safety, product description, installation at the reading station, electrical connection through the CDB 410 or CDM 410 connection module, operation and configuration with the CLV Setup PC software, maintenance, troubleshooting and technical data, with an appendix.

Its parts

  1. Notes on this document
  2. Safety information
  3. Product description
  4. Installation
  5. Electrical connection
  6. Operation
  7. Maintenance
  8. Troubleshooting
  9. Technical data
  10. Appendix

From the manual

Key facts from this manual

Each line names its page in the PDF.

The SICK operating instructions for the CLV 41x fixed-focus bar code scanners, covering the CLV 410 (Standard), CLV 412 (High Density) and CLV 414 (Short Range) in line and raster versions. They explain installation, wiring through the CDB 410 or CDM 410 connection module, quick start with factory defaults, configuration, error status codes, troubleshooting, technical data and accessories.

Read for this summary: pages 19 to 22, 42, 55 to 57, 80 to 82, 87 to 88 and 126 to 127 of 142.

What it is
Fixed-focus industrial laser bar code scanner, line or raster, with a front or side reading window p. 21
Host interfaces
RS 232 and RS 422/485, 300 to 57,600 bd; SICK Standard and SICK Network protocols p. 87
Power
5 to 30 V DC, max. 3 W p. 88
Bar code types
Code 39, Code 128, Code 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved, Pharmacode p. 87
Scan frequency
200 to 800 Hz; red laser, 670 nm p. 87
Temperature
Operating 0 to +40 °C (+32 to 104 °F); storage –20 to +70 °C (–4 to +158 °F) p. 88
Type suffixes
-0010 line scanner, -1010 raster scanner, -2010 and -3010 the same with a 105° angle attachment p. 87
Reading range
CLV 410: 50 to 380 mm (1.97 to 14.97 in), resolution 0.2 to 1.0 mm (7.8 to 39.4 mil) p. 21
Connector
All interfaces on one 15-pin D Sub HD connector, cable length 0.9 m (35.5 in) p. 22, 88
Switching I/O
2 optodecoupled inputs (Sensor 1 reading pulse, Sensor 2 teach-in), max. 30 V; 3 PNP outputs, 600 mA max. p. 87, 88
Connection modules
CDB 410-001 (no. 1 023 813) or CDM 410-0001 (no. 1 025 361), 6 to 30 V DC; CMP 400 (no. 2 029 468) AC plug-in power supply for the CDM 410 p. 126
Cables
6 010 075 extension cable to CDB/CDM 410; 6 010 137 cable with open end for a non-SICK power pack; 2 014 054 RS 232 null modem cable, PC to CDB/CDM 410 p. 127
Other accessories
Programming adapter 7 034 552; small mounting bracket 2 020 077; large mounting bracket 2 020 078 p. 126, 127
Weight and housing
250 g (8.8 oz) with cable, about 320 g (11.3 oz) with angle attachment; zinc die-cast, IP 65 p. 88

What this manual walks you through

  • What comes in the box p. 19
  • What is needed to start up and run the scanner p. 20
  • Pin assignment of the 15-pin D Sub HD plug p. 42
  • Factory default settings p. 55, 56
  • Quick start with the factory defaults and the polling reflector p. 57
  • Reading the ST error status codes p. 80
  • Troubleshooting a scanner that is not ready p. 81
  • Troubleshooting reading pulse errors p. 82
  • Fieldbus modules for Profibus DP, DeviceNet, Interbus-S and Ethernet p. 126, 127

Good to know

  • The manual states the CLV 41x is UL certificated only when a class 2 power supply according to UL 1310 is used. p. 20
  • By default the laser diode switches off 10 minutes after a reading pulse starts, with the sensor input or serial interface pulse types. p. 81, 87
  • The scanner reports errors only through the ST error status in the reading result. p. 80
  • At most 10 codes per reading pulse (100 characters in all) and 3 per scan can be read. p. 22
  • For ST status 3 (device fault), run the self-test; if the result is not 15000, the manual says to contact SICK Service. p. 80

Questions this manual answers

What power supply does the SICK CLV 410 need?

5 to 30 V DC at up to 3 W, normally through a CDB 410 or CDM 410 connection module, or from a non-SICK supply of at least 3 W using cable no. 6 010 137. p. 20, 88

What are the CLV 41x default serial settings?

9,600 bd, 8 data bits, no parity and 1 stop bit, with STX as start character and ETX as stop character. p. 56

What is the difference between the CLV 410, CLV 412 and CLV 414?

The CLV 410 is the Standard version, the CLV 412 High Density and the CLV 414 Short Range. p. 19

What does ST error status 2 mean on a SICK CLV scanner?

No bar code of an enabled code type was found during the reading pulse, for example because no code was in range, the code type was not enabled, or the window was dirty. p. 80

How do I connect a PC to a CLV 41x for setup?

Use a 3-core RS 232 null modem cable such as no. 2 014 054 to host interface 2 in the CDB 410 or CDM 410 module. p. 20

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. 1 Notes on this document13
    1. 1.1 Function13
    2. 1.2 Target audience13
    3. 1.3 Information content13
    4. 1.4 Symbols used14
  2. 2 Safety information15
    1. 2.1 Authorized personnel15
    2. 2.2 Intended use15
    3. 2.3 General safety instructions and protection measures16
    4. 2.4 Quick stop and quick restart18
    5. 2.5 Environmental information18
  3. 3 Product description19
    1. 3.1 Design19
    2. 3.2 Method of operation24
    3. 3.3 Indicators and operating elements25
  4. 4 Installation29
    1. 4.1 Overview of installation sequence29
    2. 4.2 Installation preparations29
    3. 4.3 Installing and adjusting the device35
    4. 4.4 Installing external components36
    5. 4.5 Removing the device39
  5. 5 Electrical connection41
    1. 5.1 Overview of the connection sequence41
    2. 5.2 Electrical connections and cables41
    3. 5.3 Connector pin assignment42
    4. 5.4 Preparations for electrical connection43
    5. 5.5 Making electrical connections44
  6. 6 Operation55
    1. 6.1 Overview of procedure for starting up the CLV55
    2. 6.2 Default settings55
    3. 6.3 Quick start57
    4. 6.4 Configuration (parameterizing)58
    5. 6.5 Operating modes and outputting the reading result68
    6. 6.6 CLV messages76
    7. 6.7 Switching off the CLV76
  7. 7 Maintenance77
    1. 7.1 Cleaning during operation77
    2. 7.2 Maintenance78
    3. 7.3 Disposal78
  8. 8 Troubleshooting79
25 more lines, from page 79 on
  1. 8.1 Overview of errors and malfunctions which could occur79
    1. 8.2 Monitoring errors and malfunctions79
    2. 8.3 Error messages80
    3. 8.4 Troubleshooting81
    4. 8.5 SICK Support86
  2. 9 Technical data87
    1. 9.1 Data sheet CLV 41x bar code scanner (fixed focus)87
    2. 9.2 CLV dimensional drawings89
  3. 10 Appendix91
    1. 10.1 Overview91
    2. 10.2 Specification diagrams91
    3. 10.3 Installation and operating instructions for the PC-based "CLV Setup" program95
    4. 10.4 Configuring the CLV with profile bar codes106
    5. 10.5 Configuring the CLV with command strings112
    6. 10.6 Calculating parameter values for setting the CLV114
    7. 10.7 Tables115
    8. 10.8 Special applications and procedures116
    9. 10.9 Replacing a CLV (copying the parameter set)123
    10. 10.10 Accessories126
    11. 10.11 Dimensional drawings of the accessories128
    12. 10.12 Supplementary documentation129
    13. 10.13 Glossary130
    14. 10.14 EC Declaration of Conformity136
    15. 10.15 Index137
    16. 10.16 Bar code samples141

From the PDF’s own bookmarks.

The whole text · 17 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 61-6
  2. Pages 7 to 127-12
  3. Pages 13 to 1813-18
  4. 3 Product description19-28
  5. 4 Installation29-40
  6. 5 Electrical connection41-54
  7. 6 Operation, pages 55 to 6255-62
  8. 6 Operation, pages 63 to 7063-70
  9. 6 Operation, pages 71 to 7671-76
  10. Pages 77 to 8677-86
  11. 9 Technical data87-90
  12. 10 Appendix, pages 91 to 9991-99
  13. 10 Appendix, pages 100 to 108100-108
  14. 10 Appendix, pages 109 to 117109-117
  15. 10 Appendix, pages 118 to 126118-126
  16. 10 Appendix, pages 127 to 135127-135
  17. 10 Appendix, pages 136 to 142136-142

The file

Revision and size

Revision8 009 974/O079/01-09-2004
PublisherSICK AG
Pages142
PDF2.2 MB
TextText from the PDF itself.

The first pages · 3 of 142

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 142
Page 2
Page 2of 142
Page 3
Page 3of 142