Page 127

Appendix

Operating Instructions

Chapter 10

CLV 41x bar code scanner

Order no.

Type

Description

6 025 756

BMH 10-0411

Bus module for connection of one CLV to Ethernet TCP/IP. Data transmission rate 10 MBit/s. With terminal screws, a 8-pin RJ-45 bus socket, no housing, for top-hat-rail installation, enclosure rating max. IP 20, operating voltage 10 to 30 V DC

6 007 655

–

Power cable for BMS 10, 3-wire, length 2 m (6.56 ft), with 3-pin connector (grounding) and one open end (stripped)

Table 10-7: Accessories: bus connection modules (contd.)

10.10.4 Programming adapter Order no.

Description

7 034 552

Programming adapter with 15-pin D-Sub HD plug/socket, 9-pin D-Sub plug to connect the PC (RS 232), a switch to connect the host interface 2 of the CLV either to the host or to the PC, 3 LEDs to indicate the status of the switching outputs “Result 1“ to “Result 3“, a push button switch to trigger the reading pulse in the CLV via the “Sensor 1“ switching input

Table 10-8: Accessories: Progamming adapter

10.10.5 Cables and plug-in connections Order no.

Description

Wires

Length

Connection

6 010 075

Extension cable for data and functional interfaces, ∅ 6.5 mm (0.27 in), shielded, with 15-pin D Sub HD socket and plug

15

2m (6.56 ft)

CLV 41x to CDB 410/ CDM 410

6 010 137

Connection cable for data and functional interfaces, ∅ 6.5 mm (0.27 in), with 15-pin D Sub HD socket and one open end (stripped)

15

2m (6.56 ft)

CLV 41x to nonSICK power pack

2 014 054

Data connection cable RS 232, ∅ 5 mm (0.2 in), shielded, with two 9-pin D Sub sockets. SICK null modem cable (pin 2 (RxD) and pin 3 (TxD) crossed)

3

3m (9.84 ft)

PC to CDB 410/ CDM 410

6 010 088

Data cable, ∅ 6.6 mm (0.27 in), shielded, for connection cables up to 3 m 15 x (9.84 ft) long 0.09 mm2 (28 AWG)

Cut to size free

6 007 508

Data cable, ∅ 8.5 mm (0.33 in), twisted pair, shielded

Cut to size SICK network (RS 485)

6 009 438

D Sub connector housing (metal) for 9-pin or 15-pin HD inserts

6 007 335

D Sub connector insert, 9-pin socket connector

6 010 019

D Sub connector insert, 15-pin HD socket connector

6 010 020

D Sub connector insert, 15-pin HD pin connector

2x2x 0.23 mm2 (24 AWG)

Table 10-9: Accessories: cables and plug-in connections

8 009 974/O079/01-09-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-37

Page 128

Appendix

Chapter 10

Operating Instructions CLV 41x bar code scanner

10.10.6 Reading pulse generators Order no.

Description

4 030 794

Polling reflector, white, for short distances up to 0.5 m (19.7 in) (included in scope of supply)

4 030 795

Polling reflector, blue, with removable protective film, for long distances 0.5 to 0.8 m (19.7 to 31.5 in) (included in scope of supply)

4 032 086

Polling reflector for CLV 412 (high density)

Table 10-10: Accessories: reading pulse generators (polling reflectors)

The SICK catalog "SENSICK Industrial Sensors" (order no. 8 006 530, English version) contains a large selection of photoelectric switches and photoelectric proximity switches as well as the associated accessories (brackets, connection cables) 10.10.7 Network controller Order no.

Type

Description

On request

CLX 200

Network controller with LCD, membrane-sealed keyboard, integrated power pack and 9-pin D-Sub connections for network, host and terminal, enclosure rating max. IP 31

Table 10-11: Accessories: Network controller

10.11 Dimensional drawings of the accessories 10.11.1 Mounting bracket

Included for mounting the CLV: - 2 pan-head screws M4 x 8 mm (0.32 in), hex-head w/s 3 mm, self-locking - 2 washers A4.3 - 2 lock washers B4

Fig. 10-13: Dimensions of the mounting bracket no. 2 020 077

Included for mounting the CLV: - 2 pan-head screws M4 x 8 mm (0.32 in), hex-head w/s 3 mm, self-locking - 2 washers A4.3 - 2 lock washers B4

Fig. 10-14: Dimensions of the mounting bracket no. 2 020 078

10-38

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 974/O079/01-09-2004

Page 129

Operating Instructions

Appendix

Chapter 10

CLV 41x bar code scanner

10.12 Supplementary documentation Part No.

Title

Language

Contents

8 010 000

“CDB 410 Connection Module“ Operating Instructions

German/ English

Description for connecting the CLV to the host/PLC/sensor via the CDB 410 Connection Module

8 010 003

“CDM 410 Connection Module“ Operating Instructions

German/ English

Description for connecting the CLV to the host/PLC/sensor via the CDM 410 Connection Module

8 010 365

“CMP 400 Power Supply Module“ Operating Instructions

German/ English

Description for installing the module in the CDM 410 Connection Module

8 008 825

"BMV/BMH 10 for Profibus DP" operating instructions

English

Description for connecting the CLV to the Profibus/the PLC/the sensor via the bus connection module BMV/bus module BMH 10

8 008 972

"BMV/BMH 10 for DeviceNet" operating instructions

8 007 546

"BMS 10/20 for Interbus S" technical information

English

Description for connecting the CLV to the Interbus S/the PLC/ the sensor via the bus connection module BMS 10/20

8 009 398

"BMV/BMH 10 for Ethernet" operating instructions

English

Description for connecting the CLV to the Ethernet/the PLC/the sensor via the bus connection module BMV/bus module BMH 10

8 007 675

"Master/Slave with CLV bar code scanners" Technical information

English

Description of the structure of a "daisy-chain configuration" (master/slave or data forwarding)

8 007 157

"Network Controller CLX 200" Technical Description

German/ English

Description of a SICK Network (RS 485) with CLV Bar Code Scanners

On request

Commando strings

English

Description of the CLV command strings

Description for connecting the CLV to the DeviceNet/the PLC/ the sensor via the bus connection module BMV/bus module BMH 10

Table 10-12: Supplementary documentation (English versions)

10.12.1 CLV Connect (from Version 1.9) Diagrams showing you how to connect the CDB 410 or CDM 410 Connection Module are also available in the “CLV Connect“ PC program. This software is available on the “Manuals & Software“ CD ROM, which is included in the scope of delivery of the CLV 41x. The software can also be downloaded from the SICK home page (www.sick.de) at “Service&Support/Downloadpool“. It can be called up using a standard HTML browser (e. g. Internet ExplorerTM).

8 009 974/O079/01-09-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-39

Page 130

Chapter 10

Appendix

Operating Instructions CLV 41x bar code scanner

10.13 Glossary For additional terms, see also Online help – CLV Setup Help. Aperture angle α Angle within whose limits the laser beam is deflected by the polygon mirror wheel. A V-shaped range perpendicular to the scan direction, which must contain the bar code, is formed in front of the reading window. If only part of this aperture angle is used (part of the scan line symmetric around the center point), the depth of field for the focus position and resolution is greater. Aspect ratio Ratio of the code height (bar length) to the code length (number of characters). AutoSetup Function that allows the code and reading configuration of the CLV to be adapted automatically to the application at hand. The CLV searches for a bar code that is presented at a fixed distance and the optimum scan rate. It enters the code type and code length and disables all other code types and lengths. CLV Assistant The Assistant simplifies parameterization and testing of the CLV, among other things. It carries out configuration of the CLV for a user-specific reading situation with one bar code in simple steps. The determined settings are transferred to CLV Setup. CLV Setup PC program which runs under Windows 95TM/98TM, Windows NT4.0TM, Windows 2000TM and Windows XPTM. Used for offline parameterizing (adjustment to the reading application at hand) and the online operation of the CLV. The Ö parameter set is exchanged with the CLV by Ö uploading and Ö downloading it. CLV Setup Help Online help function that provides support for using the "CLV Setup" program. The help function contains explanations of the CLV parameters and their valid entries. Can be launched directly from CLV Setup in an HTML browser such as "Internet ExplorerTM". Code geometry Length and height dimensions of the bar code. Code position (CP value) Position of the first dark bar in a detected bar code along the Ö scan line. Calculated by the CLV for each scan and can be used, for example, to separate bar codes with identical data contents. The active evaluation range in the scan line can be restricted for Ö decoding purposes by specifying the maximum and minimum CP value for the application. Command strings, commands CLV user interface - alternative to the "CLV Setup" program. Basic, yet clearly structured command language for modifying the CLV parameter sets online. Accesses the CLV command interpreter directly. Special programming activities are required to use the command strings from the host.

10-40

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 974/O079/01-09-2004

Page 131

Operating Instructions

Appendix

Chapter 10

CLV 41x bar code scanner

Configuration file File in the CLV Setup program that archives the entire Ö parameter set of the CLV. Can be printed out in the form of a table. Data forwarding Option of forwarding data sent by the host transparently to a terminal via the CLV using an identifier. Data can also be forwarded in the opposite direction. Furthermore, this function also allows data received on one of the serial interfaces to be output again straight away on one of the same interfaces (echo). Application: forwarding reading results or reading pulse commands in pass-through mode, e.g. in a master/slave network. Data output string Structured data telegram Ö in the reading result output by the CLV on the Ö host interfaces 1 and 2. The structure of the data string is flexible and can be adapted to a large extent to the subsequent data processing task. Decoder, decoding Code-type-specific evaluation routine for reconstructing the read bar code in electronic form in order to decode its data content. Download Method of transferring the Ö parameter set that was modified with the Ö CLV Setup program offline from the PC to the CLV. CLV Setup either always transfers a complete copy to the memory (RAM) of the CLV (DOWNLOAD TO CLV) or just the parameter previously processed using the context menu of the right mouse button (DOWNLOAD PARAMETER) or all parameters of the displayed tab (DOWNLOAD PARAMETERS OF THIS VIEW). You can overwrite the existing parameter set in EEPROM of the CLV by choosing the "Permanent" save option. Error message Detected device faults outputs the CLV by sending the error status ST= 3 via the host interface in reading mode. The CLV outputs further coded error messages (3 digits, 15xxx) only in the Self-test mode. Error status Identifier output with the reading result by the CLV for errors that were diagnosed while the bar code was being read. The entry for the host interface is made in the separator of the Ö data output string and must be enabled using the parameters (disabled by default in the CLV 41x). Focus position Distance of the focal point of the emitted laser beam in front of the reading window. Creates a distance-specific depth of field (DOF) in which the bar code can be recorded. Functional interfaces Switching inputs and outputs on the CLV. Good Read The CLV successfully detected a bar code or the required number of bar codes specified by the evaluation parameters during the Ö reading pulse.

8 009 974/O079/01-09-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-41

Page 132

Chapter 10

Appendix

Operating Instructions CLV 41x bar code scanner

Header Data block in the reading result of the Ö host interface. Used as a header in the Ö data output string for the subsequent data content of the bar code. Contains up to 10 elements, consisting of reading diagnosis data and/or constants (control characters, letters, digits), depending on the configuration. The "Header" block is empty in the default setting of the CLV 41x. Host Interface Data interface on the CLV with configurable data output format. Used to output the Ö reading result in telegram form to the host/PLC. Integrates the CLV in the SICK network or builds a master/slave arrangement. The interface is also temporarily used to configure the CLV. The CLV provides two host interfaces which operate parallel (logical drivers of both interfaces active): host interface 1: RS 422/485, host interface 2: RS 232. It supports various transfer protocols. Line scanner Scanner that uses a polygon mirror wheel with paraxial mirrors to deflect a focused laser beam extremely fast. As a result, it creates a light spot in the reading plane that moves along a straight line, which appears to the naked eye as a stationary scan line. Master/slave configuration Special arrangement for connecting up to max. 7 CLVs in the SICK network to one reading station (e.g. left/right read). Thanks to the master, the entire network appears as one device to the host. Multiple read Variable number of reading operations that must provide identical reading results (data content) of the same bar code before the CLV outputs the result. No Read The CLV failed to detect a bar code or the required number of bar codes specified by the evaluation parameters during the Ö reading pulse. No Read format Special, parameterizable data block as a substitute for bar codes, which were expected but not detected, in the data output string on the host interface for Ö no reads. Comprises a variable combination of the error string and the Ö separator. Parameter set Data record used to initialize and activate the functions implemented in the CLV. With Ö downloading and Ö uploading, the parameter set is transferred from CLV Setup to the CLV or from the CLV to CLV Setup. Percentage Evaluation Special operating mode in which the quality of the reads (but not the bar codes) is assessed statistically. The bar codes must be stationary. The CLV carries out 100 scans and evaluates the reading quality. It then outputs the reading results on the Ö host interface every 2 s together with the Ö reading diagnosis data.

10-42

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 974/O079/01-09-2004

Page 133

Operating Instructions

Appendix

Chapter 10

CLV 41x bar code scanner

Profile bar code Special bar codes that are created and printed using the Ö CLV Setup program. They contain coded parameters/parameter values from the parameter set. The profile bar codes can be used to configure the CLV with its optical interface (reading window) instead of a PC. Raster height Distance between the first and last of the eight parallel scan lines for the Ö raster scanner. The raster width is the distance between two adjacent scan lines. Raster scanner Scanner that uses a polygon mirror wheel with eight tilted mirrors to deflect its focused laser beam extremely quickly. As a result, it creates a light spot that moves quickly in eight rows across the reading plane. Each light spot repeatedly moves along a straight line. It thereby appears to human eyes as one of eight stationary scan lines. Reading area (DOF) Depth of field around the focal point of the laser beam on two sides. The extent of the reading range depends on the resolution and reading distance. Reading diagnosis data Data directly derived from the reading procedure by the CLV. This data enables the quality of the read to be assessed. The data is always output on the Ö terminal interface together with the reading result. Only output on the host interface if enabled on the DATA STRINGS tab in the CLV Setup program (disabled by default for CLV 41x). Reading field height Length of the Ö scan line that is available for detecting the bar code in the reading plane. Due to the V-principle of beam generation, the reading field height is dependent on the reading distance. Reading interval Timeslot in which the CLV activates the laser diode and attempts to detect valid bar codes from the information read. The reading interval may be shorter than the external reading pulse, depending on the selected output mode for the reading result. Reading pulse Pulse applied externally to the CLV to trigger the internal Ö reading interval. Can be supplied by a photoelectric reflex switch or a command from the host on the serial interface. Reading result Electronic representation of the data content of the read bar code together with the Ö reading diagnosis data in one Ö data output string that is generated after the reading pulse has elapsed. The reading result on the host interface can be configured separately for good reads and no reads. Special characters can also be added if necessary. Reflector polling Reading pulse generated automatically by the CLV using a special bar code that serves as a reflector for the laser beam. The bar code is positioned opposite the CLV. The CLV polls

8 009 974/O079/01-09-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

10-43

Page 134

Chapter 10

Appendix

Operating Instructions CLV 41x bar code scanner the reflector at regular intervals. When it is concealed by an object, the CLV starts the reading interval. It stops the reading interval once it detects the reflector again. Result status output Function of the "Result 1" to "Result 3" switching outputs and the beeper in Reading mode. Signals the status of the reading result without indicating its contents (e.g. Good Read). You can assign a status to each output on the DEVICE CONFIGURATION tab in the user interface of CLV Setup. The “Result“ LED operates independent of the outputs and indicates only Good Read in the Reading mode (until the end of the next reading pulse). Scan line See line scanner. Separator Data block in the reading result of the Ö host interface. Used to add useful data to each bar code. Can be attached to the bar code as a prefix or suffix. Contains up to 10 elements, consisting of reading diagnosis data and/or constants (control characters, letters, digits). The "Separator" block is empty in the default setting of the CLV 41x. Specification diagrams Diagrams for reading the resolution-specific depth of field (DOF) for specific focus positions. Storage in the CLV The application-specific Ö parameter set can be stored temporarily or permanently in the CLV. If it is stored temporarily in the RAM, it is lost as soon as the power supply is switched off. Parameter sets that are stored permanently are transferred to the EEPROM in the CLV and remain active as the current data record when the power supply is switched off. The default setting is not affected by this and is stored in a read-only memory (ROM). Teach-in Method of programming the information required to adjust the CLV to the reading application in Parameter mode. Example: teaching-in match code 1 or teaching-in the application-specific bar code in Ö AutoSetup. Terminator Data block in the reading result of the Ö host interface. Used to terminate the data content of the bar code. Contains up to 10 elements, consisting of reading diagnosis data and/or constants (control characters, letters, digits). The “Terminator“ block is empty in the default setting of the CLV 41x. Transmission time Point at which the reading result is output with respect to the start of the Ö reading pulse and the internal Ö reading interval. Upload Method of transferring the Ö parameter set from the CLV to the PC Ö using the CLV Setup program. CLV Setup either transfers a complete copy of the current parameter set from the memory (RAM) of the CLV (UPLOAD TO CLV) or just the parameter previously processed using the context menu of the right mouse button (UPLOAD PARAMETER) or all parameters of the

10-44

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 974/O079/01-09-2004

Page 135

Operating Instructions

Appendix

Chapter 10

CLV 41x bar code scanner displayed tab (UPLOAD PARAMETERS OF THIS VIEW). Displays the current parameter values on the tabs. Prerequisite for modifying the current parameter set. User interface Windows-based PC software "CLV Setup" for operating and configuring the CLV.

8 009 974/O079/01-09-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved